A Meta-Analysis of the Diagnostic Accuracy of Two Commercial NS1 Antigen ELISA Tests for Early Dengue Virus Detection

Abstract

Background

Dengue virus (DENV) NS1 antigen detection is regarded as an early diagnostic marker. Accordingly, several studies have evaluated the performance of tests that utilize NS1 capture, but the results of individual studies may be limited due to the restricted sample size of the patients recruited. Therefore, our objective was to perform a meta-analysis of the diagnostic accuracy of two commercial NS1 ELISAs (Panbio and Platelia).

Methods and Results

Studies of interest were found in PubMed, Embase and Google Scholar databases using defined inclusion/exclusion criteria. A total of 30 studies containing 12,105 total enrolled patients were included. The results were as follows: 1) Panbio assays showed low overall performance, sensitivity 66% (95% confidence interval (CI) 61–71), specificity 99% (95% CI 96–100), positive likelihood ratio (LR+) 98 (95% CI 20–464), negative likelihood ratio (LR-) 0.3 (95% CI 0.2–0.4), diagnostic odds ratio (DOR) 289 (95% CI 59–1412); 2) Platelia assays showed high overall performance, sensitivity 74% (95% CI 63–82), specificity 99% (95% CI 97–100), LR+ 175 (95% CI 28–1099), LR- 0.3 (95% CI 0.2–0.4), DOR 663 (95% CI 98–4478). The lowest sensitivity values were for secondary infections (57% [95% CI 47–67] and 66% [95% CI 53–77] for Panbio and Platelia, respectively) and for the detection of DENV4. Regarding clinical manifestations, the sensitivity of Platelia was 69% (95% CI 43–86) and 60% (95% CI 48–70) for fever and dengue hemorrhagic fever, respectively. In addition, the sensitivity of both tests was slightly lower for samples from Southeast Asia and Oceania.

Conclusion

DENV1 samples gave higher sensitivity results for both tests. We observed that factors negatively influencing the tests, such as the type of infection, geographical origins of samples and viral serotypes, require further investigation to optimize the diagnostic accuracy.

Introduction

Dengue is a pandemic disease that has been neglected but is reemerging, putting approximately three billion people in tropical and subtropical regions at risk of this viral infection [1], [2]. Therefore, dengue poses a major threat to the public health systems of many countries, considering the occurrence of millions of cases and thousands of deaths annually [3].

Dengue virus (DENV), genus Flavivirus, is antigenically classified into four serotypes (DENV1-4). DENV is an arbovirus (Arthropod-borne virus) and is increasingly infecting humans, with the incidence of dengue showing a 30-fold increase within the last 50 years [3][6]. Dengue disease results in a wide clinical spectrum with undifferentiated febrile symptoms, hindering early diagnosis and clinical management. Thus, DENV infections can be asymptomatic or present as the classical clinical picture of dengue fever (DF). In revised WHO classification system (2009), DF was divided into dengue with or without warning signs and severe dengue. We will use the classification into DF/dengue hemorrhagic fever (DHF)/or dengue shock syndrome (DSS), since it continues to be widely used [2], [7].

Laboratory techniques involved in the diagnosis of DENV are based on the detection of viral genetic material, the specific detection of IgG/IgM antibodies and the detection of viral antigens, such as nonstructural protein 1 (NS1) [8][10]. NS1 is a glycoprotein that is abundantly produced by viruses in the early stages of infection, and it is found within the infected cells, in the cell membranes and secreted into the extracellular spaces [11], [12]. Therefore, one advantage of laboratory methods that perform NS1 antigen capture is the precocity of this marker, present at the onset of symptoms, in contrast to IgM, which is detected later, beginning at the fifth day of disease.

Currently, several laboratory methods that use the capture of DENV NS1 antigen are available [13][17]. The successful implementation of these methods reflects on the good performance of these tests. Despite the existence of several studies evaluating tests for an NS1 capture ELISA assay, no meta-analysis evaluating the diagnostic accuracy of these commercial kits has been performed. Due to the limited sample size of patients recruited in individual studies, meta-analysis may increase the accuracy of estimates of individual studies. Therefore, we conducted a meta-analysis of the accuracy of diagnosis for Panbio NS1 and Platelia NS1 ELISA assay kits to obtain the overall estimated and summarized performance of the tests in the detection of DENV.

Materials and Methods

Search strategy

This meta-analysis was guided by the standard PRISMA protocol (Preferred Reporting Items for Systematic reviews and Meta-analysis (Table S1)) and methods proposed by the Cochrane Collaboration [18], [19]. PubMed; Embase and Google Scholar databases were searched for articles using a combination of descriptors to select the studies of interest.

Study selection

After finding previously published studies in the databases with the descriptors “dengue” OR “dengue virus” AND “diagnosis” OR “ELISA NS1” OR “early diagnostic” OR “diagnostic accuracy” OR “performance test”, we performed an analysis on the inclusion/exclusion criteria.

As inclusion criteria, we used studies that evaluated the sensitivity and specificity parameters of ELISA kits involving the capture of dengue NS1 antigen and the Panbio (Alere, Brisbane, Australia) or Platelia (Marnes-la-Coquette, France; Hercules, CA, USA (Bio-Rad)) kits.

As exclusion criteria, we did not review studies that were not published in English, Spanish or Portuguese or studies with limited information for calculating sensitivity and specificity. We excluded specific articles types, for instance review articles, comments, the editorial, letters and conference abstract. Additionally, two authors reviewed the studies independently, in case of disagreement a third author was consulted.

Data extraction

The following data from each study included in the meta-analysis were extracted: author, year of publication, place of study, gender, age and number of participants, method of diagnosis, study design, sensitivity and specificity data, positive predictive value (PPV) and negative predictive value (NPV). The data to be extracted were analyzed in the following subgroups: classification of infection, viral serotype, period of the collection of samples, geographic origin of patients and clinical picture presented. Subsequently, the data related to the accuracy of the diagnosis were plotted on a 2×2 contingency table.

Quality assessment

The analysis of the quality of the studies was performed based on a tool known as the quality assessment of diagnostic accuracy studies (QUADAS), which allows for the identification of important design elements in diagnostic accuracy studies [20]. The QUADAS tool consists of 14 key items (sufficient test description and reference, representative spectrum, reported withdrawals and indeterminate results, relevant clinical information, index test results blinded, definition positive test result, cutoff values, complete verification of diagnosis, avoided clinical review bias, appropriate selection and reference standard, and acceptable detail between tests). Items are evaluated using a score of “low”, “high”, or “obscure”, which are formulated for an answer as “no”, “yes” and “unclear”, respectively, that may indicate low or high risk of publication bias. Each of 14 items was scored from 1 to 0, with a total quality score between 11 and 14 was considered “good”, between 7 and 10, “moderate”, and 6 or less was considered “poor”.

Statistical analysis

STATA IC/64 software (version 13.1, College Station, TX) with MIDAS and METANDI commands was used for the meta-analysis. For correction in the cells containing zero values, correction factors from METANDI commands were used.

The sensitivity (true positive rate), specificity (true negative rate), positive likelihood ratio and negative (LR+, or LR-, is estimated by the ratio of the proportion of positive, or negative, tests in the diseased versus no-diseased subjects) and diagnostic odds ratio (DOR is calculated as the LR+ divided by the LR-), with a confidence interval (CI) of 95%, were obtained for each study and subsequently combined. Cochran Q chi-square test and the I2 statistic were explored to assess the heterogeneity of the included studies. Random-effects model was used if the result of the Q test was significant (p<0.05) and I2>50%. The meta-regression was planned to be used if there was high heterogeneity (I2>50%) [21]. Additionally, an hierarchical summary receiver operating characteristic (HSROC) type curve of the selected studies was then plotted with the software. The HSROC curve is a bivariate model that provides information on the overall performance of a test through different thresholds. We also constructed the summary receiver operating characteristics (SROC) curve and the respective area under the curve that serves a global measure of the test performance [22].

To assess potential publication bias, we used the Deeks funnel plot, with p<0.05 indicating the presence of publication bias [23]. Fagan nomograms, a two-dimensional graphical tool for estimating how much the result of a diagnostic test changes the probability that a patient has a disease, was also used to estimate the clinical value of the index test, which is based on the LR+ and LR- obtained from the meta-analysis [24].

Results

Our search found 672 citations related to dengue through the combined application of descriptors in the three databases described above. During the final stage of selection, we excluded five studies that only assessed the sensitivity of laboratory methods or did the overlap the results of the two tests in their analysis [13][17]. After the exclusion criteria were applied, 30 baseline studies remained [25][54], which were included in our meta-analysis because they involved experimental research evaluating the diagnostic accuracy of the Panbio or Platelia kits, which used NS1 antigen capture in an indirect ELISA format. The results of our literature search are shown in Figure 1.

thumbnail
Figure 1. Flowchart of the steps performed in the meta-analysis.

https://doi.org/10.1371/journal.pone.0094655.g001

Among the studies included in the meta-analysis, there were a total of 12,105 patients recruited. These patient samples were collected from 17 countries in Latin America, Asia and Oceania, and the most studies were conducted in Brazil (27%) [29], [34], [37], [41], [45], [47], [52], [54], Vietnam (13%) [32], [33], [36], [49], Malaysia (13%) [26], [36], [42], [46] and Thailand (13%) [31], [36], [43], [48]. Regarding the design of the studies, they were classified into two types: prospective and retrospective cohorts, of which only twelve reported that their samples were collected during dengue outbreaks [25], [26], [30], [37], [39], [40], [44], [45], [51][54]. Typically, most samples were collected until the sixth day of the onset of symptoms [25], [27], [28], [30][37], [40][42], [47], [49], [50], [52][54]. The data extracted from the final selection are shown in Table 1.

The QUADAS tool consists of 14 items, and the results of the analysis can be seen in Figure 2. The quality of all studies was generally moderate, with median QUADAS score of 9 (Table S2). However, the items related to the determination of the indeterminate results, including relevant clinical information (classification DF or DHF) and disclosure of the cut-off and blinding of samples before processing by laboratory tests, were evaluated items that presented more risk of bias. Additionally, the Deeks funnel plot did not show potential publication bias for the two subgroups of studies (p = 0.56 and p = 0.09) (Figure S1), yet a significant amount of heterogeneity were detected for the two tests (I2 ranged from 85% to 97%). Meta-regression showed that the covariates, origin of the samples, period of sample collection and retrospective versus prospective samples were items that contributed to diversity among studies (Table S3).

thumbnail
Figure 2. The assessment of methodological quality items shown for all included studies.

Proportions of studies rated as “yes”, “no”, or “unclear” for each QUADAS item.

https://doi.org/10.1371/journal.pone.0094655.g002

Overall accuracy of the Panbio and Platelia commercial kits

Among the selected studies, 16 assessed the trials of Panbio [27], [28], [30], [35][41], [45], [47], [48], [50][52] and 23 assessed the trials of Platelia [25][27], [29][39], [42][44], [46], [47], [49], [50], [53], [54]. In relation to Panbio, the sensitivity, specificity, LR+, LR- and DOR overall were 66% (95% CI 61–71), 99% (95% CI 96–100), 98 (95% CI 19–367), 0.3 (95% CI 0.2–0.4) and 289 (95% CI 59–1412), respectively. Similarly, the values for Platelia were 74% (95% CI 63–82), 99% (95% CI 97–100), 175 (95% CI 28–1099), 0.3 (95% CI 0.2–0.4) and 663 (95% CI 98–4478), respectively. The area under summary ROC curve were 0.84 (95% CI 0.80–0.87 (Panbio)) and 0.96 (95% CI 0.94–0.97 (Platelia)) (Figure S2) and the graphs of the HSROC curves of the individual studies for the diagnostic accuracy of two tests analyzed are shown in Figure 3A–B.

thumbnail
Figure 3. HSROC plot displaying diagnostic accuracy results of included studies.

Panbio (A) and Platelia (B) kits. The circle diameter (study estimate) is proportional to the weight given to each study. Summary sensitivity and specificity is marked by a red square.

https://doi.org/10.1371/journal.pone.0094655.g003

Accuracy of the tests on the viral serotype and classification of infection

When evaluating the accuracy of tests for sensitivity, DOR, LR+ and LR- for serotype DENV1, we obtained the following values: 81% (95% CI 73–87), 702 (95% CI 101–4842), 136 (95% CI 23–806) and 0.2 (95% CI 0.1–0.3), respectively, for Panbio. Similarly, the values for Platelia were 90% (95% CI 81–95), 5460 (95% CI 131-225878), 526 (95% CI 12-21602) and 0.09 (95% CI 0.04–0.19).

For DENV2, pooled sensitivity was 74% (95% CI 67–80), DOR was 507 (95% CI 55–4663), LR+ and LR- were 133 (95% CI 17-1023) and 0.3 (95% CI 0.2–0.4), respectively, for Panbio. In Platelia, pooled sensitivity was 73.3% (95% CI 61–83), DOR was 714 (95% CI 37-13466), LR+ and LR- were 191 (95% CI 12-3090) and 0.26 (95% CI 0.17–0.4), respectively.

For DENV3, pooled sensitivity was 70.7% (95% CI 63–78), DOR was 481 (95% CI 33-6869), LR+ and LR- were 141 (95% CI 11-1780) and 0.3 (95% CI 0.2–0.4), respectively, for Panbio. In Platelia, pooled sensitivity was 83% (95% CI 75–89), DOR was 2353 (95% CI 72-7e+4), LR+ and LR- were 397 (95% CI 12-13119) and 0.16 (95% CI 0.11–0.25), respectively.

For DENV4, pooled sensitivity was 37% (95% CI 26–50), DOR was 18 (95% CI 6–63), LR+ and LR- were 12 (95% CI 4–38) and 0.6 (95% CI 0.5–0.8), respectively, for Panbio. In Platelia, pooled sensitivity was 58% (95% CI 30–81), DOR was 96848 (95% CI 14–6e+8), LR+ and LR- were 41006 (95% CI 6–3e+8) and 0.4 (95% CI 0.2–0.8), respectively.

Regarding the classification of dengue primary or secondary infection types, the following global estimates for primary infection were obtained for the parameters of sensitivity, DOR, LR+ and LR-: 75% (95% CI 66–82.5), 7114 (95% CI 18–2e+6), 1761 (95% CI 5-601666) and 0.24 (95% CI 0.17–0.34), respectively, for Panbio, and 94.6% (95% CI 91–97), 2036 (95% CI 341–12130), 110 (95% CI 23–518) and 0.05 (95% CI 0.03–0.09), respectively, for Platelia. For secondary infection, these laboratory indices were 57% (95% CI 47–67), 3443 (95% CI 12–9e+5), 1484 (95% CI 6–4e+5) and 0.4 (95% CI 0.3–0.5), respectively, for Panbio, and 66% (95% CI 53–77), 632 (95% CI 47–8374), 216 (95% CI 13–3453) and 0.3 (95% CI 0.2–0.5), respectively, for Platelia.

Accuracy of the tests regarding clinical manifestations of dengue

To verify whether patients with moderate clinical forms (DF) or severe dengue (DHF/DSS) showed significant variations in the performance of the tests, we performed a global estimate of the accuracy of the tests. In this case, only Platelia was used for laboratory evaluation of the different clinical forms of the patients. Only five studies performed this calculation, with forest plot of sensitivity showing values that ranged from 25% to 95% (Figure 4A–B). The pooled sensitivity was 69% (95% CI 43–86) and 60% (95% CI 48–70) for DF (A) and DHF (B), respectively.

thumbnail
Figure 4. Forest plot of the sensitivity of Platelia kit.

Forest plot of the sensitivity of each study and pooled sensitivity for studies that distinguished clinical features of patients infected with DENV into DF (A) and DHF (B). The sensitivity is represented by the circles in squares and the horizontal lines represent the point estimate (95% CI for each included study). Diamonds represent the pooled estimate (95% CI).

https://doi.org/10.1371/journal.pone.0094655.g004

DOR and post-test probability

The DOR is commonly considered a global measure of test performance that summarizes the diagnostic accuracy of the index test as a single number that describes how many times greater the chance is of getting a positive result in a person with the disease than in someone without the disease. As described above, the values of DOR were considerably high due to the high values of sensitivity and principally of the specificity observed in this study. In this case, a function of DOR plotted on the graph would present an exponential behavior, rising abruptly and presenting a clear positive correlation with the sensitivity and specificity [55], [56].

To obtain the post-test probability, we used Fagan's nomogram for which we performed a simulation of an environment that had a prevalence of 37% for dengue disease, with base on the studies selected. Thus, the probability in this model of someone having the disease and not being detected by the NS1 Panbio ELISA test was 17%. In the same situation for the NS1 Platelia ELISA test, a negative result was associated with 13% of individuals with the disease (Figure 5A–B). In contrast, the post-test probability of sick patients with a positive test was 98% and 99%, respectively, for Panbio and Platelia. Thus, showing that these tests specifically capture the NS1 antigen is important in the diagnosis of dengue.

thumbnail
Figure 5. Fagan's nomogram for the calculation of post-test probabilities.

A pre-test probability of 37% for dengue disease was fixed, which was estimated by the number of symptomatic cases in selected studies. (A) Panbio had a post-test probability of 98%. For Platelia kits (B) post-test probability was 99%, ie, with an estimated prevalence of 37%, if this patient tests positive, the post-test probability that she truly has dengue would be 99% (solid line in red). On the other hand, if patient tests negative, the post-test probability that she truly has dengue would be 17% (A) or 13% (B) (blue dotted line). The results were obtained by the following calculations: pretest odds = prevalence/1-prevalence; post-test odds = pretest odds x LR- (LR+); post-test probability = post-test odds/1+post-test odds. LR, likelihood ratio.

https://doi.org/10.1371/journal.pone.0094655.g005

Discussion

The studies included in this meta-analysis had a global sensitivity and specificity ranging from 45% to 100% and 71% to 100%, respectively, for Panbio and ranging from 0% to 95% and from 47% to 100%, respectively, for Platelia. When we performed an overall estimate of sensitivity, a superiority of Platelia (74% [95% CI 63–82]) over Panbio (66% [95% CI 61–71]) was detected. With respect to this increased sensitivity of the former test, there are no hypotheses explaining this outcome, but it has been observed that viral serotype can influence the accuracy of the test, thereby changing the sensitivity and resulting in both the Panbio and Platelia tests having higher sensitivity for DENV1. However, there were more participants with DENV1 included for analysis using the Platelia test [25], [27], [28], [30], [35][37], [39], [44], [47], [53], a fact that may have influenced the overall estimate, although our results are similar to the scientific literature, which demonstrates a higher sensitivity for Platelia.

Our findings in relation to the sensitivity of the tests against viral serotypes are partially consistent with the scientific literature, with a lower sensitivity observed for both tests (37% for Panbio and 58% for Platelia) for DENV4. However, some studies have also reported a lower sensitivity for Platelia for DENV2 [30], [35], [36], [47], [50]. The low accuracy of the Panbio during an epidemic of DENV4 and Platelia were recently analyzed by Colombo et al. [52] and Sea et al. [54], who observed the occurrence of false negatives. It is not yet known why the NS1 ELISA has a lower sensitivity in the patients infected with DENV4, but some hypotheses can be postulated: (i) there could be quantitative differences in the secreted NS1 form, depending on the viral serotype, which may lead to less availability of NS1 and reduced chances of detection, (ii) the higher incidence of DENV4 in secondary infections, and (iii) there could be presence of polymorphism in the NS1 gene associated with immune epitopes. However, these speculations require additional studies to confirm them.

In silico analysis using the Virus Pathogen Resource software (ViPR: www.viprbrc.org) to assess the degree of variability of the NS1 protein of DENV1-4 serotypes of the complete sequences from Asia (1466 strains) versus South America (476 strains) revealed the existence of significant variability between NS1 sequences. At least 83 amino acid positions were identified (Table S4). However, in the known consensus NS1 region “111LRYSWKTWGKA121[57], there was only one polymorphism (replacing R with K at position 112) in DENV4; this polymorphism was found in 23 strains from South America and Asia. Thus, it appears that this polymorphism is not the main factor influencing the test but will be important for understanding whether external variant amino acids can have some influence on the immune epitope.

The detection and semi-quantitation of NS1 is proportional to the optical density (OD) measured at 450/620 nm [10]. The kits that were analysed determine the cut off by the average and standard deviations of the OD values from calibrators and the values are expressed in scales that can be interpreted as negative, indeterminate or positive. The calibration curve for the detection of NS1 is obtained by comparing different dilutions of the antigen, and the resulting values are expressed in OD units, as measured using an ELISA reader. Accordingly, Young et al. [12] calculated the linear portion of the standard curve to determine the serum NS1 concentration, obtaining a minimum threshold of 4 ng/ml. If there are quantitative differences in the secretion of NS1, depending on the different DENV serotypes, this could reduce the sensitivity of the test when certain dilutions are made. Indeed, if NS1 DENV4 is present in smaller amounts, it would be interesting to increase the detection test by obtaining a new calibration curve with lower dilutions of the test samples.

The determination of dengue diagnosis only with clinical and epidemiological data may result in errors [58], [59]. To circumvent this problem, a laboratory diagnosis is crucial for correct identification. One of the main benefits of laboratory methods is to allow the screening of patients suspected of such diseases to implement the most appropriate clinical management and to provide greater efficiency of the epidemiological surveillance system. The epidemiological surveillance systems are important in the control of outbreaks, as in cases of dengue, where movement of a new serotype of DENV often proceeds to epidemic proportions. The constant occurrence of dengue outbreaks can result in a higher incidence of secondary infections, which are positively correlated with a higher risk of DSS [60]. In this context, a lower sensitivity in patients with secondary infections was found for both analyzed tests, a fact that is worrisome because it would be useful to have a better test accuracy at this stage, due to the possibility of these patients progressing to more severe forms of the disease.

The “original antigenic sin” proposed by Sabin (1952) notes that, in successive infections by DENV, antibody memory may confer only transient protection against heterologous serotype infections, so that antibodies generated in secondary infections would be more effective in the neutralizing the viral serotype that caused the primary infection instead of the secondary one. The overall assessment of the sensitivity of both kits indicated that it was considered elevated in patients with primary infection (77% Panbio; 95.5% Platelia). In contrast, in secondary infections, there was a loss of sensitivity for both kits (24% for Panbio and 31% for Platelia). It is likely that this is due to the increased supply of antibodies, although weakly neutralizing [61], binding to the NS1 antigen. Accordingly, to increase the sensitivity of the tests, complex NS1 antibodies are separated by treatment of the test samples with acid [62]. Although this method has improved the sensitivity of the tests, only one study [31] among the ten that distinguished the types of infections [26], [28], [29], [32], [37], [39], [45], [51], [53] performed this step to dissociate antigen and antibody.

We conducted an overall estimate of the sensitivity of the kits correlated with the geographic origin of patients. The tests had a slight better accuracy for samples from Latin America, with values of 70% (95% CI 63–76 [Panbio]) and 80% (95% CI 75–85 [Platelia]), while these rates for patients who were from Southeast Asia and Oceania were 59% (95% CI 51–66 [Panbio]) and 73% (95% CI 61–82 [Platelia]). From these findings, it cannot be inferred that there were significant differences between geographical origins because even these results differ from the multicenter study conducted by Guzman et al. [36]. We believe that the differences in the sensitivity of the tests are most likely attributed to the process of the epidemiological evolution of DENV serotypes, in which a greater restriction of species from the same geographical region may be the result of the viral ancestral lineage [63]. This theory is supported by a phylogenetic analysis that elucidated the origins and molecular evolution of DENV in different geographic regions of world and showed the high genetic diversity of dengue, in which there are several clusters of different sublineages even within a single genotype [64]. In this context, Watanabe et al. [65], through studies in mice, have found that the secretion of NS1 is dependent on the viral strain. This reinforces the idea that co-circulating viral strains can affect the accuracy of tests that detect the NS1 antigen.

Although we mention above that the observed differences in laboratory parameters, in association with different geographical origins of patients, are mainly due to a process of molecular evolution of DENV, we cannot rule out the influence of the host in these molecular dynamics. In this sense, Mairiang et al. [66] found that there are several interactions between the protein of DENV and human and mosquito hosts. Therefore, there may be an interaction between the genotype of the host and the pathogen (DENV), although this has been demonstrated only in the main dengue vector, Aedes aegypti [67]. While the host may influence the molecular dynamics of the evolution of the pathogen, to what extent this influences the pathogen infecting humans in certain geographical regions and how this may affect the laboratory methods used should be defined to improve the performance of assays.

The DOR obtained in this meta-analysis was on average usually greater than 500. In fact, the high variations of values for sensitivity and specificity were also reflected in the DOR, which may vary from zero to infinity with higher values denote a better discriminatory diagnostic test [56]. Additionally, the post-test (Fagan's nomogram) probability was also high (Figure 5A–B), indicating a good clinical utility of the tests, although caution is needed in their interpretation because the samples included in the studies were mostly from symptomatic patients suspected of dengue, which increased the overall rates of prevalence.

In addition to the NS1 ELISA, there are immunochromatographic methods, which are known as rapid tests because results are obtained on average within 30 minutes. Several studies have evaluated the NS1 rapid tests, with sensitivities ranging from 51% to 90% [13][17], [38]. So although very good methods for identification of DENV infections exist and are in use, it is prudent to include additional methods whenever possible. We believe that one of the best choices is the combination of NS1 ELISA methods and an NS1 rapid test, along with a method for detection of IgG to increase sensitivity in secondary type infections.

Our meta-analysis had several limitations. First, there are two generations of the Panbio NS1 ELISA, and the latest second-generation kit had a higher sensitivity. Among the analyzed studies, few authors identified the generation of the kits used in their experiments, so our overall estimate of the sensitivity of Panbio could be influenced by this aspect. Second, although the specificity was almost 100%, it should be noted that only a few authors used a different pathological group of dengue, while most used samples from healthy individuals and blood donors. We understand that this happens because of the abundance and ease of obtaining these samples, but it is critical to avoid biases and to test the assays more in relation to other flavivirus and similar diseases. Third, only a third of the studies made a distinction between or disclosed the serotypes of DENV. Perhaps this factor, along with precocity of the samples, had a greater influence on the accuracy of tests. Fourth, there was statistically significant heterogeneity across the included studies. In an effort to explore source of heterogeneity, meta-regression revealed that origin, period and retrospective samples might is causing diversity on sensitivity and specificity. Fifth, only a few studies reported that the samples were from primary or secondary infections. Sixth, we used available data to calculate the sensitivity up to the sixth day of blood collection; however, some studies had a period of sample collection lasting until the ninth day of the febrile phase and this factor can also significantly compromise the accuracy of tests. Finally, data were not divided into additional groups based on other variables, such as gender or age, due to the limitations of original information for each patient included in the studies.

In conclusion, despite the above limitations mentioned, this meta-analysis showed a good overall estimate of sensitivity ranging from 66% (95% CI 61–71 [Panbio]) to 74% (95% CI 63–82 [Platelia]). Specificity was near 100% for both kits. The main factors influencing the diagnostic accuracy were the type of infection (primary versus secondary), viral serotype, geographical origins of samples and how early the samples were collected. However, to what extent and how these factors affect the diagnostic accuracy require more studies in order to optimize these tests.

Supporting Information

Figure S1.

Deek's funnel plot asymmetry test for publication bias. Deek's funnel plot asymmetry test not suggested potential publication bias (p = 0.56 in the Panbio kit (a)), (p = 0.09 in the Platelia kit (b)).

https://doi.org/10.1371/journal.pone.0094655.s001

(TIF)

Figure S2.

Summary ROC curve plot with sensitivity and specificity for Panbio (A) and Platelia (B). Each large X represents individual study in meta-analysis. Summary operating point is a single sensitivity/specificity point estimated by the results of studies. AUC =  area under the curve.

https://doi.org/10.1371/journal.pone.0094655.s002

(TIF)

Table S2.

Methodological quality of the 30 included studies.

https://doi.org/10.1371/journal.pone.0094655.s004

(XLSX)

Table S3.

Univariate meta-regression analyses of the sensitivity and specificity.

https://doi.org/10.1371/journal.pone.0094655.s005

(DOCX)

Table S4.

Amino acid positions of NS1 identified with significant variations. The positions and variability were obtained by the crossing of the NS1 strains DENV1-4 from Asia and South America.

https://doi.org/10.1371/journal.pone.0094655.s006

(XLSX)

Author Contributions

Conceived and designed the experiments: VGC MLM. Performed the experiments: VGC ACMS MLM. Analyzed the data: VGC ACMS. Contributed reagents/materials/analysis tools: VGC. Wrote the paper: VGC.

References

  1. 1. Hotez PJ, Bottazzi ME, Franco-Paredes C, Ault SK, Periago MR (2008) The neglected tropical diseases of Latin America and the Caribbean: a review of disease burden and distribution and a roadmap for control and elimination. PLoS Negl Trop Dis 2: e300
  2. 2. WHO (2009) Dengue guidelines for diagnosis, treatment, prevention and control. Available: http://whqlibdoc.who.int/publications/2009/9789241547871_eng.pdf. Accessed 2013 December 16.
  3. 3. Guzman MG, Halstead SB, Artsob H, Buchy P, Farrar J, et al. (2010) Dengue: a continuing global threat. Nat Rev Microbiol 8: S7–S16
  4. 4. Chambers TJ, Hahn CS, Galler R, Rice CM (1990) Flavivirus genome organization, expression, and replication. Annu Rev Microbiol 10: 649–688
  5. 5. Phillips ML (2008) Dengue reborn: widespread resurgence of a resilient vector. Environ Health Perspect 116: A382–8. PubMed: 18795135.
  6. 6. Tabachnick WJ (2010) Challenges in predicting climate and environmental effects on vector-borne disease episystems in a changing world. J Exp Biol 213: 946–954
  7. 7. Martina BE, Koraka P, Osterhaus AD (2009) Dengue virus pathogenesis: an integrated view. Clin Microbiol Rev 22: 564–8
  8. 8. Lai YL, Chung YK, Tan HC, Yap HF, Yap G, et al. (2007) Cost-effective real-time reverse transcriptase PCR (RT-PCR) to screen for Dengue virus followed by rapid single-tube multiplex RT-PCR for serotyping of the virus. J Clin Microbiol 45: 935–941
  9. 9. Alexander DQF, Aralí MVR, Elvira OR, Angel VCL (2006) Evaluation of IgM determination in acute serum for the diagnosis of dengue in an endemic area. Enferm Infecc Microbiol Clin 24: 90–92. PubMed: 16545316.
  10. 10. Alcon S, Talarmin A, Debruyne M, Falconar A, Deubel V, et al. (2002) Enzyme-linked immunosorbent assay specific to dengue virus type 1 nonstructural protein NS1 reveals circulation of the antigen in the blood during the acute phase of disease in patients experiencing primary or secondary infections. J Clin Microbiol 40: 376–381
  11. 11. Shu PY, Huang JH (2004) Current advances in dengue diagnosis. Clin Diagn Lab Immunol 11: 642–650
  12. 12. Young PR, Hilditch PA, Bletchly C, Halloran W (2000) An antigen capture enzyme-linked immunosorbent assay reveals high levels of the dengue virus protein NS1 in the sera of infected patients. J Clin Microbiol 38: 1053–1057. PubMed: 10698995.
  13. 13. Kumarasamy V, Chua SK, Hassan Z, Wahab AHA, Chem YK, et al. (2007) Evaluating the sensitivity of a commercial dengue NS1 antigen-capture ELISA for early diagnosis of acute dengue virus infection. Singapore Med J 48: 669–73. PubMed: 17609831.
  14. 14. Chuansumrit A, Chaiyaratana W, Pongthanapisith V, Tangnararatchakit K, Lertwongrath S, Yoksan S (2008) The use of dengue nonstructural protein 1 antigen for the early diagnosis during the febrile stage in patients with dengue infection. Pediatr Infect Dis J 27: 43–48. PubMed: 18162937.
  15. 15. McBride WJH (2009) Evaluation of dengue NS1 test kits for the diagnosis of dengue fever. Diagn Microbiol Infect Dis 64: 31–36
  16. 16. Bisordi I, Rocco IM, Suzuki A, Katz G, Silveira VR, et al. (2011) Evaluation of dengue NS1 antigen detection for diagnosis in public health laboratories, São Paulo state, 2009. Rev Inst Med Trop Sao Paulo 53: 315–20. PubMed: 22183454.
  17. 17. Felix AC, Romano CM, Centrone CC, Rodrigues CL, Villas-Boas L, et al. (2012) Low sensitivity of NS1 protein tests evidenced during a dengue type 2 virus outbreak in Santos, Brazil, in 2010. Clin Vaccine Immunol 19: 1972–76
  18. 18. Moher D, Liberati A, Tetzlaff J, Altman DG, Altman D, et al. (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6: e1000097
  19. 19. Higgins JPT, Green S, editors (2011) Cochrane handbook for systematic reviews of interventions. Version 5.1.0:6.4.1. The Cochrane Collaboration; Available: http://www.cochrane-handbook.org. Accessed 2013 October 10.
  20. 20. Whiting P, Rutjes AWS, Reitsma JB, Bossuyt PMM, Kleijnen J (2003) The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 3: 25
  21. 21. Higgins JP, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses. BMJ 327: 557–560
  22. 22. Jones CM, Athanasiou T (2005) Summary receiver operating characteristic curve analysis techniques in the evaluation of diagnostic tests. Ann Thorac Surg 79: 16–20
  23. 23. Deeks JJ, Macaskill P, Irwig L (2005) The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol 58: 882–893
  24. 24. Fagan TJ (1975) Letter: Nomogram for Bayes theorem. N Engl J Med 293: 257
  25. 25. Dussart P, Labeau B, Lagathu G, Louis P, Nunes MRT, et al. (2006) Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum. Clin Vaccine Immunol 13: 1185–89
  26. 26. Kumarasamy V, Wahab A, Chua SK, Hassan Z, Chem YK, et al. (2007) Evaluation of a commercial dengue NS1 antigen-capture ELISA for laboratory diagnosis of acute dengue virus infection. J Virol Methods 140: 75–79. Available: http://dx.doi.org/10.1016/j.jviromet.2006.11.001. Accessed 2013 December 14.
  27. 27. Bessoff K, Delorey M, Sun W, Hunsperger E (2008) Comparison of two commercially available dengue virus (DENV) NS1 capture enzyme-linked immunosorbent assays using a single clinical sample for diagnosis of acute DENV infection. Clin Vaccine Immunol 15: 1513–18
  28. 28. Blacksell SD, Mammen Jr MP, Thongpaseuth S, Gibbons RV, Jarman RG, et al. (2008) Evaluation of the Panbio dengue virus nonstructural 1 antigen detection and immunoglobulin M antibody enzyme-linked immunosorbent assays for the diagnosis of acute dengue infections in Laos. Diagn Microbiol Infect Dis 60: 43–49
  29. 29. Castro LA (2008) Avaliação da detecção da proteína NS1 no diagnóstico da infecção pelo vírus dengue-3 em comparação a outros métodos laboratoriais utilizados no diagnóstico da dengue. Dissertação de Mestrado em Imunologia Básica e Aplicada. Universidade de São Paulo, Ribeirão Preto, SP. 100p.
  30. 30. Dussart P, Petit L, Labeau B, Bremand L, Leduc A, et al. (2008) Evaluation of two new commercial tests for the diagnosis of acute dengue virus infection using NS1 antigen detection in human serum. PLoS Negl Trop Dis 2: e280
  31. 31. Lapphra K, Sangcharaswichai A, Chokephaibulkit K, Tiengrim S, Piriyakarnsakul W, et al. (2008) Evaluation of an NS1 antigen detection for diagnosis of acute dengue infection in patients with acute febrile illness. Diagn Microbiol Infect Dis 60: 387–91
  32. 32. Hang VT, Nguyet NM, Trung D, Tricou V, Yoksan S, et al. (2009) Diagnostic accuracy of NS1 ELISA and lateral flow rapid tests for dengue sensitivity, specificity and relationship to viraemia and antibody responses. PLoS Negl Trop Dis 3: e360
  33. 33. Phuong HL, Thai KTD, Nga TTT, Giao PT, Hung LQ, et al. (2009) Detection of dengue nonstructural 1 (NS1) protein in Vietnamese patients with fever. Diagn Microbiol Infect Dis 63: 372–78
  34. 34. Poloni TRRS (2009) Detecção e tipificação do vírus da dengue por RT-PCR em tempo real. Dissertação de mestrado em Biociências Aplicadas à Farmácia. Universidade de São Paulo. Ribeirão Preto, SP. 56p.
  35. 35. Ramirez AH, Moros Z, Comach G, Zambrano J, Bravo L, et al. (2009) Evaluation of dengue NS1 antigen detection tests with acute sera from patients infected with dengue virus in Venezuela. Diagn Microbiol Infect Dis 65: 247–53
  36. 36. Guzman MG, Jaenisch T, Gaczkowski R, Hang VTT, Sekaran SD, et al. (2010) Multi-country evaluation of the sensitivity and specificity of two commercially-available NS1 ELISA assays for dengue diagnosis. PLoS Neglected Trop Dis 4: e811
  37. 37. Lima MRQ, Nogueira RMR, Schatzmayr HG, Santos FB (2010) Comparison of three commercially available dengue NS1 antigen capture assays for acute diagnosis of dengue in Brazil. PLoS Negl Trop Dis 4: e738
  38. 38. Osorio L, Ramirez M, Bonelo A, Villar LA, Parra B (2010) Comparison of the diagnostic accuracy of commercial NS1-based diagnostic tests for early dengue infection. Virol J 7: 361
  39. 39. Pok KY, Lai YL, Sng J, Ng LC (2010) Evaluation of nonstructural 1 antigen assays for the diagnosis and surveillance of dengue in Singapore. Vector-Borne Zoonotic Dis 10: 1009–16
  40. 40. Singh MP, Majumdar M, Singh G, Goyal K, Preet K, et al. (2010) NS1 antigen as an early diagnostic marker in dengue: report from India. Diagn Microbiol Infect Dis 68: 50–54
  41. 41. Araújo FMC, Brilhante RSN, Cavalcanti LPG, Rocha MFG, Cordeiro RA, et al. (2011) Detection of the dengue non-structural 1 antigen in cerebral spinal fluid samples using a commercially available enzyme-linked immunosorbent assay. J Virol Methods 177: 128–31
  42. 42. Chua KB, Mustafa B, Abdul Wahab AH, Chem YK, Khairul AH, et al. (2011) A comparative evaluation of dengue diagnostic tests based on single-acute serum samples for laboratory confirmation of acute dengue. Malays J Pathol 33: 13–20. PubMed: 21874746.
  43. 43. Chuansumrit A, Chaiyaratana W, Tangnararatchakit K, Yoksan S, Flamand M, Sakuntabhai A (2011) Dengue nonstructural protein 1 antigen in the urine as a rapid and convenient diagnostic test during the febrile stage in patients with dengue infection. Diagn Microbiol Infect Dis 71: 467–69
  44. 44. Duong V, Ly S, Try PL, Tuiskunen A, Ong S, et al. (2011) Clinical and virological factors influencing the performance of a NS1 antigen-capture assay and potential use as a marker of dengue disease severity. PLoS Negl Trop Dis 5: e1244
  45. 45. Lima MRQ, Nogueira RMR, Filippis AMB, Santos FB (2011) Comparison of two generations of the Panbio dengue NS1 capture enzyme-linked immunosorbent assay. Clin Vaccine Immunol 18: 1031–33
  46. 46. Kassim FM, Izati MN, TgRogayah TAR, Apandi YM, Saat Z (2011) Use of dengue NS1 antigen for early diagnosis of dengue virus infection. Southeast Asian J Trop Med Public Health 42: 562–9. PubMed: 21706934.
  47. 47. Silva FG, Silva SJS, Rocco IM, Silveira VR, Suzuki A, et al. (2011) Evaluation of commercial kits for detecting the antigen NS1-dengue-São Paulo. Bepa 8: 14–26.
  48. 48. Watthanaworawit W, Turner P, Turner CL, Tanganuchitcharnchai A, Jarman RG, et al. (2011) A prospective evaluation of diagnostic methodologies for the acute diagnosis of dengue virus infection on the Thailand-Myanmar border. Trans R Soc Trop Med Hyg 105: 32–37
  49. 49. Anders KL, Nguyet NM, Quyen NTH, Ngoc TV, Tram TV, et al. (2012) An evaluation of dried blood spots and oral swabs as alternative specimens for the diagnosis of dengue and screening for past dengue virus exposure. Am J Trop Med Hyg 87: 165–70
  50. 50. Blacksell SD, Jarman RG, Gibbons RV, Tanganuchitcharnchai A, Mammen Jr MP, et al. (2012) Comparison of seven commercial antigen and antibody enzyme-linked assays for detection of acute dengue infection. Clin Vaccine Immunol 19: 804–10
  51. 51. Aryati A, Trimarsanto H, Yohan B, Wardhani P, Fahri S, Sasmono RT (2013) Performance of commercial dengue NS1 ELISA and molecular analysis of NS1 gene of dengue viruses obtained during surveillance in Indonesia. BMC Infect Dis 13: 611
  52. 52. Colombo TE, Vedovello D, Araki CS, Cogo-Moreira H, Dos Santos INP, et al. (2013) Dengue 4 false negative results by Panbio dengue early ELISA assay in Brazil. J Clin Virol 58: 710–13
  53. 53. Kosasih H, Alisjahbana B, Widjaja S, Nurhayati, Mast Q, et al. (2013) The diagnostic and prognostic value of dengue nonstructural 1 antigen detection in a hyper-endemic region in Indonesia. PLoS One 8: e80891
  54. 54. Sea VRF, Cruz ACR, Gurgel RQ, Nunes BTD, Silva EVP, et al. (2013) Underreporting of dengue-4 in Brazil due to low sensitivity of the NS1 Ag test in routine control programs. PLoS One 8: e64056
  55. 55. Buehler AM, Figueró M, Moreira FR, Cavalcanti AB, Sasse A, Berwanger O. Diretrizes metodológicas: elaboração de revisão sistemática e meta-análise de estudos diagnósticos de acurácia. Available: http://200.214.130.94/rebrats/publicacoes/dbrs_Diagn_v_final.pdf. Accessed 2013 December 17.
  56. 56. Glas AS, Lijmer JG, Prins MH, Bonsel GJ, Bossuyt PMM (2003) The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol 56: 1129–35
  57. 57. Falconar AK, Young PR, Miles MA (1994) Precise location of sequential dengue virus subcomplex and complex B cell epitopes on the nonstructural-1 glycoprotein. Arch Virol 137: 315–26. PubMed: 7944953.
  58. 58. Daumas RP, Passos SR, Oliveira RV, Nogueira RM, Georg I, et al. (2013) Clinical and laboratory features that discriminate dengue from other febrile illnesses: a diagnostic accuracy study in Rio de Janeiro, Brazil. BMC Infect Dis 8: 13–77
  59. 59. Terzian AC, Mondini A, Bronzoni RV, Drumond BP, Ferro BP, et al. (2011) Detection of Saint Louis encephalitis virus in Dengue-suspected cases during a dengue 3 outbreak. Vector Borne Zoonotic Dis 11: 291–300
  60. 60. Huy NT, Van Giang T, Thuy DH, Kikuchi M, Hien TT, et al. (2013) Factors associated with dengue shock syndrome: a systematic review and meta-analysis. PLoS Negl Trop Dis 7: e2412
  61. 61. Wahala WMPB, Silva AM (2011) The human antibody response to dengue virus infection. Viruses 3: 2374–95
  62. 62. Koraka P, Burghoorn-Maas CP, Falconar A, Setiati T, Djamiatun K, et al. (2003) Detection of immune-complex-dissociated nonstructural-1 antigen in patients with acute dengue virus infections. J Clin Microbiol 41: 4154–59
  63. 63. Costa RL, Voloch CM, Schrago CG (2012) Comparative evolutionary epidemiology of dengue virus serotypes. Infect Genet Evol 12: 309–314
  64. 64. Weaver SC, Vasilakis N (2009) Molecular evolution of dengue viruses: contributions of phylogenetics to understand the history and epidemiology of the preeminent arboviral disease. Infect Genet Evol 9: 523–540
  65. 65. Watanabe S, Tan KH, Rathore APS, Rozen-Gagnon K, Shuai W, et al. (2012) The magnitude of dengue virus NS1 protein secretion is strain dependent and does not correlate with severe pathologies in the mouse infection model. J Virol 86: 5508–14
  66. 66. Mairiang D, Zhang H, Sodja A, Murali T, Suriyaphol P, et al. (2013) Identification of new protein interactions between dengue fever virus and its hosts, human and mosquito. PLoS One 8: e53535
  67. 67. Fansiri T, Fontaine A, Diancourt L, Caro V, Thaisomboonsuk B, et al. (2013) Genetic mapping of specific interactions between Aedes aegypti mosquitoes and dengue viruses. PLoS Genet 9: e1003621