A Morphological Hessian Based Approach for Retinal Blood Vessels Segmentation and Denoising Using Region Based Otsu Thresholding

  • Khan BahadarKhan ,

    kb.khattak@gmail.com

    Current address: Faculty of Engineering and Technology, Department of Electronic Engineering, Sector H-10, International Islamic University, Islamabad, Pakistan

    Affiliation Department of Electronic Engineering, International Islamic University, Islamabad, Pakistan

  • Amir A Khaliq,

    Affiliation Department of Electronic Engineering, International Islamic University, Islamabad, Pakistan

  • Muhammad Shahid

    Affiliation Department of Computer Engineering, CUST, Islamabad, Pakistan

Correction

1 Sep 2016: Bahadar Khan K, A Khaliq A, Shahid M (2016) Correction: A Morphological Hessian Based Approach for Retinal Blood Vessels Segmentation and Denoising Using Region Based Otsu Thresholding. PLOS ONE 11(9): e0162581. https://doi.org/10.1371/journal.pone.0162581 View correction

Abstract

Diabetic Retinopathy (DR) harm retinal blood vessels in the eye causing visual deficiency. The appearance and structure of blood vessels in retinal images play an essential part in the diagnoses of an eye sicknesses. We proposed a less computational unsupervised automated technique with promising results for detection of retinal vasculature by using morphological hessian based approach and region based Otsu thresholding. Contrast Limited Adaptive Histogram Equalization (CLAHE) and morphological filters have been used for enhancement and to remove low frequency noise or geometrical objects, respectively. The hessian matrix and eigenvalues approach used has been in a modified form at two different scales to extract wide and thin vessel enhanced images separately. Otsu thresholding has been further applied in a novel way to classify vessel and non-vessel pixels from both enhanced images. Finally, postprocessing steps has been used to eliminate the unwanted region/segment, non-vessel pixels, disease abnormalities and noise, to obtain a final segmented image. The proposed technique has been analyzed on the openly accessible DRIVE (Digital Retinal Images for Vessel Extraction) and STARE (STructured Analysis of the REtina) databases along with the ground truth data that has been precisely marked by the experts.

Introduction

DR is a severe disease and is one of the main source of visual impairment among adults aged 20–74 years in the United States [1]. The most common indications of DR include dilated retinal veins, hemorrhages, hard exudates and cotton wool spots [2]. Variation in features of vasculature of retinal images lead to serious diseases such as stroke, diabetes and cardiovascular diseases [3]. Consequently, an investigation of retinal vessel features can help with recognizing these progressions and permit the patient to make an action while the sickness is still in its initial stage. Automated investigation of the retinal blood vessels turned into a dynamic research because of its diagnostic and prognostic in the field of medical imaging.

Segmentation and review of retinal vasculature characteristics for example, tortuosity, normal or abnormal branching, shading and diameter as well as the optic disk morphology permits eye care experts and ophthalmologists to perform mass vision screening exams for early discovery of retinal ailments and treatment assessment. This could forestall and decrease vision debilitations, age-related diseases, and numerous cardiovascular ailments, and in addition diminish the expense of the screening [4, 5]. In manual assessment, segmentation and estimation accuracy also fluctuates relying upon nature of the retinal images, graders ability and experience. Moreover, manual segmentation and estimation procedures can take up to an hour for assessment of just a single eye. In this way, a completely automated framework extracting the vessel structures in retinal images could surely diminish the workload of eye clinicians.

This work consists of automated segmentation of vasculature of retinal images which can be used in diagnostic of various eye diseases. Different retinal vessel segmentation methodologies have been published and assessed in literature but they still need some improvement. Existing systems should be enhanced in terms of at least one of the following drawbacks. Firstly, lack of adaptive capabilities under varying image conditions may cause poor quality of segmentation such as under and over segmentations. Secondly, complex preprocessing and postprocessing operations used in different methods for extracting retinal images vessels caused high computational cost. Thirdly, human participation is required to choose area of interest, which demonstrates that the systems are not totally automatic. In conclusion, segmentation and assessment procedures themselves need a large computational endeavors.

Related Works

In literature, many retinal segmentation methods are designed from the line detection methods, as vessel segmentation depends on line detection [6]. Generally, vessel segmentation methods consists of two steps: vessels enhancement and vessels classification. Some techniques may escape first step and use directly the second step. In the first step vessels are enhanced, noise and geometrical objects are removed. Chaudhuri et al. [7], first proposed matched filter to enhance and segment retinal vessels. Further improvements and similar techniques were proposed later on by various authors using threshold probing technique [8], double-sided thresholding [9] and the first order derivative of Gaussian image [10]. Matched filters application for segmentation, produced high quality results at the cost of long computational time. The quality of segmentation results mainly depend on the quality and size of the used vessel profile database. In [11], retinal blood vessels have been enhanced by using Gabor filter. This methodology has a great performance on normal retinal images. Lam and Yan [12], used laplacian operator and gradient vector fields to extract vessels. Staal et al. [13], proposed a framework depends on extraction of image ridges, which correspond roughly with vessel centerlines. Zana and Klein [14] and Mendonça and Campilho [15], used morphological filters to enhance vessels. Their proposed method showed better results than most of the existing techniques on the pathological retina.Martínez-Pérez et al. [16, 17], were also based on hessian matrix to extract multiscale feature for detection of vessels. In [18], vessel enhancement filter was designed on the base of hessian matrix.

After vessel enhancement, second step is the classification of pixels into vessel and non-vessel pixels. This second step is also known as vessel tracking and tracing [19]. Pixels intensities based classification is used to find a suitable threshold. Jiang and Mojon [20], performed adaptive local thresholding to extract vessels. In [21], Support Vector Machine (SVM) is used along with adaptive local thresholding to classify vessel and non-vessel pixels. Maritiner-perez et al. [17], extract information about vessel topology by using 1st and 2nd spatial derivatives of the intensity image. Zhou et al. [22], method is based on prior knowledge about retinal vessel characteristics coupled with matched filtering technique to detect the vessel structure. Al-Diri [23], utilized two pairs of contours to detect vessel boundary and sustain width of vessels. Fraz et al. [24], used first-order derivative of Gaussian filter to extract centerlines of retinal vessels before mathematical morphology to quantify vessels in retina. Generally, all vessel extraction methods can be classified into supervised segmentation [1113, 2531] and unsupervised segmentation [7, 9, 1416, 2324, 3241] with the reference to the overall system design and structure.

Rest of the paper is arranged as follows: Section II, illustrate our suggested segmentation technique in detail. The preprocessing steps consist of CLAHE and morphological filters used for vessel enhancement and illumination corrections are discussed in detail. Further, hessian matrix and eigenvalues transformation are used in a modified form to compute the second derivative of the image at two different scales, for wide and thin vessels enhancement, separately. Otsu thresholding technique has been applied to classify vessel and non-vessel pixels. Finally, pixel count based thresholding has been applied to eliminate background noise, unwanted segments and erroneously detected vessel pixels. In section III, performance evaluation criteria is defined. Section IV, discussed the experimental Results. Finally, the proposed method is concluded in section V.

Proposed Technique

Fig 1 shows block diagram of our proposed segmentation framework. We extract green channel from input RGB retinal image for further processing.

thumbnail
Fig 1. Flow chart of the proposed segmentation framework.

https://doi.org/10.1371/journal.pone.0158996.g001

The green band of input image is further analyzed by using following noteworthy steps:

  • CLAHE and morphological filters have been used for vessel contrast enhancement and low frequency noise/geometrical objects removal respectively.
  • Hessian matrix and eigenvalues transformation has been applied in a modified form at two different scales to extract wide and thin vessels enhanced images, separately.
  • Global and local Otsu thresholding has been utilized in a modified way to classify vessel and non-vessel pixels from wide and thin vessel enhanced images, respectively.
  • Postprocessing steps have been used for eliminating background noise, undesired segments and erroneously detected vessel pixels. We labelled vessel pixels ‘1’ and non-vessel pixels ‘0’ to obtain a final binary image.

Contrast Limited Adaptive Histogram Equalization (CLAHE)

We have used green channel of retinal image for analysis and segmentation of vessel structure. Fig 2 shows that in green channel, blood vessels seems more differentiated than the background as compared to red or blue channel. The DRIVE and the STARE datasets images are used for analysis and experiments of the proposed method.

thumbnail
Fig 2. Retinal RGB image and its channels visual inspection.

(a) RGB input image. (b) Red channel. (c) Green channel. (d) Blue channel.

https://doi.org/10.1371/journal.pone.0158996.g002

Generally, histogram equalization techniques can acquire contrast improvement by stretching the gray level values of a low-contrast image. We used the CLAHE operator to achieve a local contrast enhanced retinal image. CLAHE used a user-defined value called clip limit to constrain enhancement by clipping the histogram [42]. The clipping level specifies noise level to be smoothen and contrast level to be enhanced in histogram. In our case, clip limit is set from 0 to 0.01.

Morphological filters

Vessel enhancement based on morphological filters has already been published in literature [14]. Vessel structure appears in more prominent contrast than background intensity variations. However, a more local investigation of vessel intensities can indicate noteworthy changes that can adversely influence the whole vessel extraction process. To overcome such changes, we have proposed a morphological filter known as modified top-hat transform which has been applied on normalized green channel image. The thickest vessel width is set as a reference, which normally varies between 1 to 8 pixels covering all diameter ranges of vessels width for both image databases utilized as a part of our proposed scheme. Vessel diameter scale can be adapted according to image resolution variations.

We have utilized morphological top-hat transformation to find difference between the input and the opened image. Closed image followed by the opened image to obtain inverse image. Implementation of top-hat transformation has an issue of noise sensitivity, which cause that pixel values in an opened image are always less than or equal to the input ones; in such conditions, the subtracted image holds little intensity variations that can be found in the data. To solve this problem we adapted from [15], modified top-hat transform by introducing two new steps: a closing operator followed by the opening, without using any minimum operator and comparison.

The opening top-hat operator of an image I with structuring element So is given by (1)

The closing top-hat operator of an image I with structuring element Sc is given by (2)

Modified top-hat transform adapted from [15] is given by (3)

Eq 3 shows our modified top-hat transform in which I is the input green channel image while Sc and So stand for the structuring elements for closing (⋅) and opening (∘) operators, respectively. In our case, we select disk type structuring elements for both opening and closing operator having radius eight pixels.

Hessian Matrix and Eigenvalues based approach

We have applied hessian matrix and eigenvalues transformation in a new way after morphological filter to obtain enhanced images of wide and thin vessel. We have computed the second derivative of the image at two different scales for wide and thin vessel enhancement, separately. This isolation of wide and thin vessels has been achieved by using hessian matrix and eigenvalues based approach. The vessels having variable width are highlighted and based on the analysis of second order derivative at two different scales. The eigenvalues of hessian matrix and the difference between them have been used for further contrast enhancement and suppression of non-vasculature structure.

Hessian matrix of the directional image Ii in the new coordinates Cx′y′ is determined as [43] (4) where (5) (6) (7)

We have applied eigenvalues transformation on hessian matrix to obtain eigenvalues λ1 and λ2, while σ is used to define scale of vessel enhancement. The filter response will be optimum, if the scale σ matches the size of the vessel. In our case, σ ranges from 1 to 2.5 for vessels enhancement. (8) (9) (10) (11) Our method reduced the complexity and computation by taking only difference of λ1 and λ2 opposed to other existing methods using Frangi’s filter [18]. Difference images are obtained as Iimage = λ2λ1 at two different scales having values 1 and 2.5 for σ.

We have tested the setting of parameter σ on different scalesas shown in Fig 3, which clearly indicates that setting of smaller scale increased False Positive Rate (FPR) considering background as a vessel pixels. In case of setting larger scale for σ, which is not able to detect thin vessel pixels decreasing the sensitivity of the proposed method.

thumbnail
Fig 3. Comparison of the setting of parameter σ on different scales.

(a) Thin vessel enhanced image. (b) Thin binary Image. (c) Thick vessel enhanced image. (d) Thick binary image.

https://doi.org/10.1371/journal.pone.0158996.g003

Otsu Method for Vessel Segmentation

We have applied Otsu’s approach [44] in a modified way to suppress the unwanted noise and geometrical objects based on vessel structure. Usually Otsu’s approach is used locally or globally on the entire image to find a threshold for classification of vessel and non-vessel pixels. Applying Otsu threshold on the whole image at once does not give fruitful results that’s why we have applied it separately on wide and thin vessel images. We have used global threshold on wide vessels enhanced image and fused its resultant image into thin vessel enhanced image. In this way both thin and thick vessels become more prominent. We obtained a single enhanced image on which further local thresholding has been applied. In local thresholding, we used vessel based thresholding which depends upon vessel locality to define a new threshold. We added some offset in the global threshold to suppress the noise more effectively for vessels in the neighborhood of wide vessels. For other regions away from wide vessels, we set lower threshold than the global by subtracting some offset from it to extract the small or thin vessels from the background having low intensity. Further, postprocessing steps have been applied to obtain final segmented image.

We used Otsu’s approach [44], to divide pixels of an image into two segments S0 and S1 (e.g., objects and background) at intensity level t, i.e, S0 = {0,1,2,…….,t} and S1 = {t + 1,t + 2,…….,L − 1}. As mentioned in [44], let σ2W,σ2B and σ2T be the within-class variance, between-class variance, and the total variance, respectively. We have minimized σ2W to obtain optimal threshold. Following is the relation between different class variances.

(12)

The optimal threshold t* in our case is obtained by maximizing α and can be defined as (13) where (14) (15) (16) (17) (18) where ni is the total number of pixels with grey-level, i and n is the total number of pixels in the given image defined as . Probability of grey-level Pi is defined as .

Postprocessing Steps

We have used pixel/area based thresholding to eliminate unconnected non-vessel pixels. The segmentation results usually consist of some small isolated regions caused by noise, and these regions are sometimes wrongly detected as vessels. Based on the connectivity of the retinal vessels, we removed less than or equal to 30 unconnected pixels considered as a non-vessel or a part of the background noise.

Performance Evaluation Criteria

We have processed retinal images from two publically available datasets: DRIVE [45] and STARE [8] for the performance evaluation of the proposed segmentation framework. These datasets consists of manual segmented retinal images by experts considered as a gold standard for comparison.

Accuracy (Acc), Sensitivity (Sn), Specificity (Sp), and the area under a Receiver Operating Characteristic (ROC) curve, also known as Area Under the Curve (AUC) are four commonly used parameters to compare the performance of the competing techniques [38]. Accuracy shows the overall segmentation performance. Sensitivity indicates effectiveness in detection of pixels with positive values: specificity measure the detection of pixels with negative values. These metrics are defined as follows: (19) (20) (21) (22) where TP, TN, FP and FN represents the True Positive, True Negative, False Positive, and False Negative pixels, respectively.

Experimental Results

In this section, we have analyzed the performance of retinal vessel segmentation methods on the DRIVE [45] and the STARE [8] databases. The manually segmented images provided in these databases are used for better evaluation of the proposed framework. The DRIVE and the STARE datasets consist of 40 and 20 retinal images, respectively classified into two sets: the training set and the test set. For performance evaluation, the proposed framework has beenapplied on 20 test images of the DRIVE and the STARE datasets. All the experiments of our proposed framework were executed utilizing MATLAB 2013a on a DELL Vostro 1540 (2.53 GHz Intel Core i3 Processor, 4GB RAM). Visual inspection of retinal blood vessel segmentation with major processing stages of our proposed framework using the DRIVE and the STARE datasets are depicted in Figs 4 and 5, respectively.

thumbnail
Fig 4. Proposed method main processing steps for retinal blood vessel segmentation.

(a) RGB image from DRIVE database. (b) Green Channel. (c) CLAHE. (d) Morphological filters. (e) Thin vessel enhanced image. (f) Wide vessel enhanced image. (g) Otsu global thresholding output image. (h) Fused image of thin enhanced image and Otsu global thresholding output image. (i) Otsu local thresholding to enhance thin vessels (j) Postprocessed final binary image.

https://doi.org/10.1371/journal.pone.0158996.g004

thumbnail
Fig 5. Proposed method main processing steps for retinal blood vessel segmentation.

(a) RGB image from STARE database. (b) Green Channel. (c) CLAHE. (d) Morphological filters. (e) Thin vessel enhanced image. (f) Wide vessel enhanced image. (g) Otsu global thresholding output image. (h) Fused image of thin enhanced image and Otsu global thresholding output image. (i) Otsu local thresholding to enhance thin vessels (j) Postprocessed final binary image.

https://doi.org/10.1371/journal.pone.0158996.g005

We have compared our visual results with Bankhead et al. [30] (S1 Link), Azzopardi et al. [35] (S2 Link), Dai et al. [40] (S3 Link), and Vlachos and Dermatas [41] (S4 Link) by running their source codes on the DRIVE and the STARE datasets shown in Figs 6 and 7, respectively. Images results of Martinez-Perez et al. [17] (S5 Link) were obtained from their website. To find whether a vessel is detected correctly or not, the final binary image has been compared to the corresponding manually segmented image.

thumbnail
Fig 6. Visual inspection of different vessel segmentation methods using DRIVE database.

(a) RGB input image. (b) Manual segmented image. (c) Proposed method final image. (d) Dai et al. [40]. (e) Azzopardi et al. [35]. (f) Bankhead et al. [30]. (g)Vlachos and Dermatas [41]. (h) Martinez-Perez et al. [17].

https://doi.org/10.1371/journal.pone.0158996.g006

thumbnail
Fig 7. Visual inspection of different vessel segmentation methods using STARE database.

(a) RGB input image. (b) Manual segmented image. (c) Proposed method final image. (d) Dai et al. [40]. (e) Azzopardi et al. [35]. (f) Bankhead et al. [30]. (g)Vlachos and Dermatas [41]. (h) Martinez-Perez et al. [17].

https://doi.org/10.1371/journal.pone.0158996.g007

Average accuracy of the proposed method

First, we have calculated the average accuracy of 20 test images of the DRIVE dataset and 20 random images of the STARE dataset. The average accuracy indicates how to extract a binary image that matches the vessel images to a high degree. The accuracy is estimated by the ratio of the sum of the number of correctly classified foreground and background pixels, divided by the total number of pixels in the image. According to the results shown in Table 1, the average accuracy for the DRIVE dataset is 0.96075 and for the STARE dataset is 0.94585.

thumbnail
Table 1. Accuracy (Acc), Sensitivity (Sn) and Specificity (Sp) results of proposed method for 20 retinal images of the DRIVE and the STARE datasets.

https://doi.org/10.1371/journal.pone.0158996.t001

Proposed Otsu algorithm comparison with different techniques

We have compared the proposed Otsu approach [44] with current thresholding algorithms, Technique of Iterative Local Thresholding (TILT) [46], K-means [47], Moment-preserving thresholding [48], Niblack local thresholding [49] and fuzzy ISODATA algorithms [50]. The pictorial results on the DRIVE dataset have been displayed in Fig 8. Their performance in the term of accuracy, sensitivity, specificity and AUC has been tabulated in Table 2.

thumbnail
Fig 8. Visual results of different thresholding techniques.

(a) Proposed Otsu method. (b) TILT. (c) K-means. (d) Moment-preserving thresholding. (e) Niblack local thresholding. (f) Fuzzy ISODATA algorithms.

https://doi.org/10.1371/journal.pone.0158996.g008

thumbnail
Table 2. Performance evaluation of different thresholding techniques with proposed Otsu method.

https://doi.org/10.1371/journal.pone.0158996.t002

Comparison with other techniques

In order to compare the efficiency of our proposed technique, we contrasted it with other existing vessel segmentation techniques on two commonly used databases: DRIVE [45] and STARE [8]. We have selected five latest supervised techniques [1113,27, 31] and fourteen unsupervised techniques [7, 9, 1416, 2324, 30, 33, 35, 3740]. The results are demonstrated in Table 3 which clearly indicates that our proposed framework is more efficient than many other methods.

thumbnail
Table 3. Performance evaluation of different retinal vessel segmentation techniques.

https://doi.org/10.1371/journal.pone.0158996.t003

Proposed framework shows highest results on the DRIVE images for both supervised and unsupervised methods, with Acc = 0.961, Sn = 0.746 and Sp = 0.980. Our proposed technique showed high efficiency in terms of sensitivity and accuracy among the unsupervised techniques on the STARE dataset. The specificity Sp = 0.963 which is also the highest value among the few unsupervised methods, and also behind the unsupervised techniques [9, 15, 24, 19, 35]. For supervised methods, accuracy is less 0.006 from [21, 27],0.0186 less from [25] and 0.011 behind [17], sensitivity is highest among all while specificity behind 0.018 than supervised methods [21, 27] and 0.013 less than [11].

One important factor of our proposed framework is to scale down the undesired segment, non-vessel pixels, erroneously detected segments and background noise that will frequently show up in the anomalous retinal images. For such pathological cases, we compared the performance of the proposed technique with various methods on the normal and abnormal images in the DRIVE and the STARE databases shown in Table 4, which evidently shows that for an abnormal cases, the proposed method achieve much better efficiency than Chaudhuri et al. [7], Mendonça and Campilho [15], Hoover et al. [8] and it records slightly better results than Soares et al. [11]. Figs 9 and 10 show visual appearance of an abnormal retinal images of the DRIVE and the STARE databases, respectively.

thumbnail
Fig 9. Pictorial results of different retinal blood vessel segmentation techniques on pathological image of DRIVE dataset.

(a) RGB input image. (b) Manual segmented image. (c) Proposed method. (d) Azzopardi et al. [35]. (e) Dai et al. [40]. (f) Bankhead et al. [30].

https://doi.org/10.1371/journal.pone.0158996.g009

thumbnail
Fig 10. Pictorial results of different retinal blood vessel segmentation techniques on pathological image of STARE dataset.

(a) RGB input image. (b) Manual segmented image. (c) Proposed method. (d) Azzopardi et al. [35]. (e) Dai et al. [40]. (f) Bankhead et al. [30].

https://doi.org/10.1371/journal.pone.0158996.g010

thumbnail
Table 4. Segmentation results comparison for normal versus abnormal cases of our proposed technique with different segmentation techniques.

https://doi.org/10.1371/journal.pone.0158996.t004

Another important parameter is ROC curve, also known as AUC, it has the ability to reflect the trade-offs between the sensitivity and specificity. Note that an AUC of 0.50 means that the classification is equivalent to a pure random guess, and an AUC of 1.0 means that the classifier distinguishes class examples perfectly. The most frequently used performance measure extracted from the ROC curve is the value of the AUC which is 1 for an optimal system. The AUC achieved by the proposed method has been contrasted with existing segmentation techniques on the DRIVE and the STARE databases shown in Table 5. The proposed framework AUC results are highest than others on the DRIVE dataset except Mapayi et al. [37] and Ricci and Perfetti [25] which is 0.001 and 0.1003 little better than ours, respectively. On the STARE dataset, AUC of the proposed method is the highest among all, only [25], [38], [37] and [35] methods are 0.107, 0.02, 0.004 and 0.001 better than ours, respectively. Table 6, represents computation time comparison of various retinal vessel segmentation techniques. Computation time of Bankhead et al. [30], Azzopardi et al. [35], Dai et al. [40], and Vlachos and Dermatas [41] have been calculated by running their source codes on the PC (HP Intel Core i3 CPU, 2.53 GHz, 4 GB RAM), while computation time of Zhao et al. [38], Nguyen et al. [34], Mapayi et al. [37] and Asad et al. [39] have been collected from their published papers. The proposed framework is computationally very fast and efficient than other published methods.

thumbnail
Table 5. Performance comparison of AUC with existing techniques.

https://doi.org/10.1371/journal.pone.0158996.t005

thumbnail
Table 6. Computation time comparison of various techniques.

https://doi.org/10.1371/journal.pone.0158996.t006

Conclusion

The automatic segmentation of blood vessels in retinal image is an important step in diagnosing causes of visual impairment. In our proposed framework, CLAHE and morphological filter has been used for vessel enhancement and low frequency noise/object removal along with hessian matrix and eigenvalues transformation to classify retinal image into wide and thin vessels enhanced images. Otsu thresholding has been utilized to extract vessel attributes and region properties based thresholding has been used set optimal threshold value to segregate vessel and non-vessel pixels. Proposed method has been applied to different databases like DRIVE and STARE and assessed based on performance measures such as sensitivity, specificity and accuracy. Further, our proposed method has been contrasted with different existing techniques to evaluate its efficiency and reliability. The proposed framework performs efficiently against noise and extract thin vessels. The proposed method is robust and computationally efficient.

Acknowledgments

The authors would like to thanks Staal et.al [45] and Hoover et.al [8] for making their database openly available.

Author Contributions

Conceived and designed the experiments: KBK AAK MS. Performed the experiments: KBK MS. Analyzed the data: KBK AAK MS. Contributed reagents/materials/analysis tools: KBK AAK MS. Wrote the paper: KBK AAK.

References

  1. 1. Klein R, Klein BE. Vision disorders in diabetes. Diabetes in America. 1995 Jul 1; 1:293–337.
  2. 2. Cavallerano J, Aiello LM. Emerging trends in ocular telemedicine: the diabetic retinopathy model. Journal of telemedicine and telecare. 2005 Jun 1; 11(4):163–166. pmid:15969790
  3. 3. Lai N, Clinical ophthalmology: A systematic approach, Optometry and Vision Science. 2004; 81(5): 295.
  4. 4. Köse C, Şevik U, İkibaş C, Erdöl H. Simple methods for segmentation and measurement of diabetic retinopathy lesions in retinal fundus images. Computer methods and programs in biomedicine. 2012 Aug 31; 107(2):274–93. pmid:21757250
  5. 5. Yavuz Z, İkibaş C, Köse C. a Simple Analytic Approach for Tracking Retinal Vessel and Measuring Their Diameters, International Conference on Bioinformatics- BIOINFORMATICS-2010, 2010.
  6. 6. Gonzalez RC. Digital image processing. Pearson Education. India; 2009.
  7. 7. Chaudhuri S, Chatterjee S, Katz N, Nelson M, Goldbaum M. Detection of blood vessels in retinal images using two-dimensional matched filters. IEEE Transactions on medical imaging. 1989; 8(3):263–9. pmid:18230524
  8. 8. Hoover A, Kouznetsova V, Goldbaum M. Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response. Medical Imaging, IEEE Transactions on. 2000 Mar; 19(3):203–10.
  9. 9. Zhang L, Li Q, You J, Zhang D. A modified matched filter with double-sided thresholding for screening proliferative diabetic retinopathy. Information Technology in Biomedicine, IEEE Transactions on. 2009 Jul; 13(4):528–34.
  10. 10. Zhang B, Zhang L, Zhang L, Karray F. Retinal vessel extraction by matched filter with first-order derivative of Gaussian. Computers in biology and medicine. 2010 Apr 30; 40(4):438–45. pmid:20202631
  11. 11. Soares JV, Leandro JJ, Cesar RM Jr, Jelinek HF, Cree MJ. Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification. Medical Imaging, IEEE Transactions on. 2006 Sep; 25(9):1214–22.
  12. 12. Lam BS, Yan H. A novel vessel segmentation algorithm for pathological retina images based on the divergence of vector fields. Medical Imaging, IEEE Transactions on. 2008 Feb; 27(2):237–246.
  13. 13. Staal J, Abramoff M, Niemeijer M, Viergever M, van Ginneken B. Ridge-based vessel segmentation in color images of the retina. IEEE Trans Med Imag. 2004; 23: 501–509.
  14. 14. Zana F, Klein JC. Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation. Image Processing, IEEE Transactions on. 2001 Jul; 10(7):1010–1019.
  15. 15. Mendonça A, Campilho AC. Segmentation of retinal blood vessels by combining the detection of centerlines and morphological reconstruction. IEEE Trans Med Imag. 2007; 25: 1200–1213.
  16. 16. Martínez-Pérez ME, Hughes AD, Stanton AV, Thom SA, Bharath AA, Parker KH. Retinal blood vessel segmentation by means of scale-space analysis and region growing. InMedical Image Computing and Computer-Assisted Intervention–MICCAI’99 1999 Jan 1; 90–97. Springer Berlin Heidelberg.
  17. 17. Martinez-Perez M, Hughes A, Thom S, Bharath A, Parker K. Segmentation of blood vessels from red-free and fluorescein retinal images. Med Image Anal. 2007; 11: 47–61. pmid:17204445.
  18. 18. Frangi AF, Niessen WJ, Vincken KL, Viergever MA. Multiscale vessel enhancement filtering. InMedical Image Computing and Computer-Assisted Interventation—MICCAI’98 1998 Oct 11; 130–137. Springer Berlin Heidelberg.
  19. 19. Fritzsche K, Can A, Shen H, Tsai C, Turner J, Tanenbuam H, et al. Automated model based segmentation, tracing and analysis of retinal vasculature from digital fundus images. State-of-The-Art Angiography, Applications and Plaque Imaging Using MR, CT, Ultrasound and X-rays. 2003 Apr 29:225–298.
  20. 20. Jiang X, Mojon D. Adaptive local thresholding by verification-based multithreshold probing with application to vessel detection in retinal images. Pattern Analysis and Machine Intelligence, IEEE Transactions on. 2003 Jan; 25(1):131–137.
  21. 21. Xu L, Luo S. A novel method for blood vessel detection from retinal images. Biomedical engineering online. 2010 Feb 28; 9(1):14.
  22. 22. Zhou L, Rzeszotarski MS, Singerman LJ, Chokreff JM. The detection and quantification of retinopathy using digital angiograms. Medical Imaging, IEEE Transactions on. 1994 Dec; 13(4):619–626.
  23. 23. Al-Diri B, Hunter A, Steel D. An active contour model for segmenting and measuring retinal vessels. Medical Imaging, IEEE Transactions on. 2009 Sep; 28(9):1488–1497
  24. 24. Fraz MM, Barman SA, Remagnino P, Hoppe A, Basit A, Uyyanonvara B, et al. An approach to localize the retinal blood vessels using bit planes and centerline detection. Computer methods and programs in biomedicine. 2012 Nov 30; 108(2):600–616 pmid:21963241.
  25. 25. Ricci E, Perfetti R. Retinal blood vessel segmentation using line operators and support vector classification. Medical Imaging, IEEE Transactions on. 2007 Oct; 26(10):1357–1365
  26. 26. Lupaşcu CA, Tegolo D, Trucco E. FABC: retinal vessel segmentation using AdaBoost. Information Technology in Biomedicine, IEEE Transactions on. 2010 Sep; 14(5):1267–1274. pmid:20529750.
  27. 27. Marín D, Aquino A, Gegúndez-Arias ME, Bravo JM. A new supervised method for blood vessel segmentation in retinal images by using gray-level and moment invariants-based features. Medical Imaging, IEEE Transactions on. 2011 Jan; 30(1):146–158.
  28. 28. Wang Y, Ji G, Lin P, Trucco E. Retinal vessel segmentation using multiwavelet kernels and multiscale hierarchical decomposition. Pattern Recognition. 2013 Aug 31; 46(8):2117–2133
  29. 29. You X, Peng Q, Yuan Y, Cheung YM, Lei J. Segmentation of retinal blood vessels using the radial projection and semi-supervised approach. Pattern Recognition. 2011 Nov 30; 44(10):2314–2324
  30. 30. Bankhead P, Scholfield CN, McGeown JG, Curtis TM. Fast retinal vessel detection and measurement using wavelets and edge location refinement. PloS one. 2012 Mar 12; 7(3):e32435 pmid:22427837
  31. 31. Niemeijer M, Staal J, van Ginneken B, Loog M, Abramoff MD. Comparative study of retinal vessel segmentation methods on a new publicly available database. InMedical Imaging. 2004 May 12; 648–656. International Society for Optics and Photonics.
  32. 32. Läthén G, Jonasson J, Borga M. Blood vessel segmentation using multi-scale quadrature filtering. Pattern Recognition Letters. 2010 Jun 1; 31(8):762–767.
  33. 33. Palomera-Pérez MA, Martinez-Perez ME, Benítez-Pérez H, Ortega-Arjona JL. Parallel multiscale feature extraction and region growing: application in retinal blood vessel detection. Information Technology in Biomedicine, IEEE Transactions on. 2010 Mar; 14(2):500–506 pmid:20007040.
  34. 34. Nguyen UT, Bhuiyan A, Park LA, Ramamohanarao K. An effective retinal blood vessel segmentation method using multi-scale line detection. Pattern recognition. 2013 Mar 31; 46(3):703–715
  35. 35. Azzopardi G, Strisciuglio N, Vento M, Petkov N. Trainable COSFIRE filters for vessel delineation with application to retinal images. Medical image analysis. 2015 Jan 31; 19(1):46–57. pmid:25240643.
  36. 36. Orlando JI, Blaschko M. Learning fully-connected CRFs for blood vessel segmentation in retinal images. InMedical Image Computing and Computer-Assisted Intervention–MICCAI 2014 Sep 14; 634–641. Springer International Publishing.
  37. 37. Mapayi T, Viriri S, Tapamo JR. Adaptive Thresholding Technique for Retinal Vessel Segmentation Based on GLCM-Energy Information. Computational and mathematical methods in medicine. 2015 Jan 1.
  38. 38. Zhao Y, Liu Y, Wu X, Harding SP, Zheng Y. Retinal vessel segmentation: An efficient graph cut approach with retinex and local phase. PloS one. 2015 Apr 1; 10(4):e0122332. pmid:25830353
  39. 39. Asad AH, Hassaanien AE. Retinal Blood Vessels Segmentation Based on Bio-Inspired Algorithm. InApplications of Intelligent Optimization in Biology and Medicine. 2016; 181–215. Springer International Publishing.
  40. 40. Dai P, Luo H, Sheng H, Zhao Y, Li L, Wu J, et al. A New Approach to Segment Both Main and Peripheral Retinal Vessels Based on Gray-Voting and Gaussian Mixture Model. PloS one. 2015 Jun 5; 10(6):e0127748. pmid:26047128
  41. 41. Vlachos M, Dermatas E. Multi-scale retinal vessel segmentation using line tracking. Computerized Medical Imaging and Graphics. 2010 Apr 30; 34(3):213–27. pmid:19892522
  42. 42. Pizer SM, Amburn EP, Austin JD, Cromartie R, Geselowitz A, Greer T, et al. Adaptive histogram equalization and its variations. Computer vision, graphics, and image processing. 1987 Sep 30; 39(3):355–368.
  43. 43. Truc PT, Khan MA, Lee YK, Lee S, Kim TS. Vessel enhancement filter using directional filter bank. Computer Vision and Image Understanding. 2009 Jan 31; 113(1):101–112.
  44. 44. Otsu N. A threshold selection method from gray-level histograms. Automatica. 1975 Jun; 11(285–296):23–27.
  45. 45. Research Section, Digital Retinal Image for Vessel Extraction (DRIVE) Database, Utrecht, The Netherlands, University Medical Center Utrecht, Image Sciences Institute. Available: http://www.isi.uu.nl/Research/Databases/DRIVE/.
  46. 46. Deng H, Fitts JP, Peters CA. Quantifying fracture geometry with X-ray tomography: Technique of Iterative Local Thresholding (TILT) for 3D image segmentation. Computational Geosciences. 2016; 1–4.
  47. 47. Jain AK, Dubes RC. Algorithms for clustering data. Prentice-Hall, Inc.; 1988 Jul 1.
  48. 48. Tsai WH. Moment-preserving thresolding: A new approach. Computer Vision, Graphics, and Image Processing. 1985 Mar 1; 29(3):377–93.
  49. 49. Niblack W. An introduction to digital image processing. Strandberg Publishing Company; 1985 Oct 1; 115–116.
  50. 50. Bezdek JC. A convergence theorem for the fuzzy ISODATA clustering algorithms. IEEE Transactions on Pattern Analysis & Machine Intelligence. 1980 Jan; 1(1):1–8.