Figures
Abstract
Introduction
Left atrial appendage closure (LAAC) with LARIAT offers an alternative to oral anticoagulation (OAC) for patients with atrial fibrillation. The aim of this study was to present long-term clinical outcomes of LAAC in these patients (AF).
Material and methods
A prospective, single-center study was performed in 139 patients undergoing LAAC with Lariat. Thromboembolic events, severe bleeding and mortality rate were recorded. The reduction in risk of thromboembolism and bleeding after LAAC was calculated.
Results
The mean CHADS2-score was 1.8 ± 1.0, mean CHA2DS2-VASc score was 2.9 ± 1.6 and HAS-BLED score was 3.1 ± 1.1. After 428.4 patient-years of follow-up (mean 4.2±1.0 years), the thromboembolism rate was 0.6% with a calculated thromboembolism risk reduction of 81%. The severe bleeding rate was 0.8%; calculated bleeding risk reduction was 78%. The overall mortality rate was 1.6%.
Citation: Litwinowicz R, Bartus M, Burysz M, Brzeziński M, Suwalski P, Kapelak B, et al. (2018) Long term outcomes after left atrial appendage closure with the LARIAT device—Stroke risk reduction over five years follow-up. PLoS ONE 13(12): e0208710. https://doi.org/10.1371/journal.pone.0208710
Editor: Carmine Pizzi, University of Bologna, ITALY
Received: August 19, 2018; Accepted: November 22, 2018; Published: December 19, 2018
Copyright: © 2018 Litwinowicz et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: The cardiac surgery data are available at Department of Cardiovascular Surgery and Transplantology, Jagiellonian University, John Paul II Hospital in Cracow, Pradnicka 80, 31- 202 Cracow, Poland (E-mail: kardiochir@szpitaljp2.krakow.pl). The authors are allowed to use these data with the approval of the Bioethics Committee at Jagiellonian University and John Paul II Hospital, Krakow, Poland. The authors confirm that others would be able to access these data in the same manner and that the authors did not have any special access privileges that others would not have.
Funding: This study is the results of the research grant No. UMO-2014/13/D/NZ5/01351 funded by the National Science Centre. KB is an recipient of the grant. URL:https://www.ncn.gov.pl/. This study is the results of the research grant No. UMO-2015/17/B/NZ5/00125 funded by the National Science Centre. KB is an recipient of the grant. URL:https://www.ncn.gov.pl/.
Competing interests: RL has equity ownership in Sentreheart. DL is co-chair of the AMAZE trial steering committee and has received an institutional research grant. KB is consultant to Sentreheart and recipient of research grant funded by the National Science Centre. This does not alter the authors' adherence to PLOS ONE policies on sharing data and materials.
Introduction
Left atrial appendage closure (LAAC) for stroke prevention in patients with atrial fibrillation (AF) is one of the fastest developing branches of interventional cardiology with the number of procedures rising annually. Currently, LAAC procedures are a recommended alternative for AF patients in whom oral anticoagulation (OAC) therapy is ineffective or contraindicated [1,2].
Exclusion of the left atrial appendage (LAA) may be performed using endocardial (Watchman, Amplatzer) or epicardial (Lariat) devices [3]. In contrast to endocardial devices, epicardial devices is an non-implant solution with does not inhibit a post LAA closure ablation procedure.
Long-term outcomes of AF patients treated with endocardial devices have demonstrated the safety and efficacy of this approach [4,5]. However, long-term outcome studies for epicardial devices are currently lacking. [3,6].
In this study we evaluated the long-term outcomes of patients with AF treated with the Lariat device in a single center.
Materials and methods
All patients were fully informed about the procedure and gave written informed consent. The protocol was conducted with the approval of the Polish Ministry of Health and the ethics committee at John Paul II Hospital, Krakow, Poland.
A prospective, single-center study was performed in 139 patients, who were referred between December 2009 and December 2012 for LAAC with the LARIAT device. Left atrial appendage occlusion with the first generation of LARIAT device (SentreHEART Inc, Redwood, CA) has been described in detail in previous studies [7–10]. Briefly, the procedure is performed with three main components: a compliant occlusion balloon, two magnet-tipped guide wires, and a 12-Fr suture delivery device. Following percutaneous pericardial approach, trans-septal puncture is performed. The first endocardial magnet-tipped guidewire is placed near the apex of the LAA. Using percutaneous femoral access, the second endocardial magnet-tipped guidewire is placed at the tip of the LAA to establish a stable connection between the wires. The LARIAT snare device is then advanced over the epicardial guidewire to occlude the LAA. After TEE and fluoroscopic confirmation of LAA closure a pre-tied suture is deployed and tightened to ligate the LAA. During procedure no periprocedural colchicine for pericarditis prophylaxis were used [3,7,8].
Post-procedure anticoagulation
Antiplatelet therapy with aspirin was recommended for all patients. However, final therapy varied due to patient comorbidities, contraindications, and physician preference.
Thromboembolism and bleeding reduction calculation
Adverse events reported during follow-up visit, based on the Munich consensus document [11], included mortality (cardiovascular, non-cardiovascular, procedural mortality, immediate procedural mortality), thromboembolic events (stroke, TIA, systemic embolism) and bleeding (life threating or disabling, major bleeding, minor bleeding).
As in our previous study[12], individual patients’ annual risk was recorded, and the average annual risk for the entire study population was calculated. The total number of thromboembolic events during overall follow-up periods were divided by the total patient years of follow-up and were multiplied by 100 to get the actual annual rate of thromboembolic events. Thromboembolism reduction was calculated as follows: (estimated %—actual % event rate)/estimated % event rate) [12,13]. Procedure efficacy to prevent thromboembolic events (stroke, TIA, systemic embolism, thrombus in the heart chamber) was calculated by comparing the actual event rate with the event rate predicted by the CHA2DS2-VASc scores [1,14,15]. Annual risk was recorded both for individual patients and the study population overall [12,13].
Bleeding reduction was assessed in a similar manner [12,13], comparing actual events with the number predicted by the HAS-BLED score [16].
Statistical analysis
Continuous variables were analyzed for normal distribution using the Shapiro-Wilk test. Data are expressed as mean ± standard deviation or median (interquartile range; Q1-25th percentile and Q3-75th percentile), unless otherwise stated. If a non-parametric test was used, the obtained data were additionally presented as mean ± standard deviation for better comparison with other studies. To assess the differences between two continuous variables, a Student’s t-test, or Mann-Whitney U-test were used as appropriate. Categorical variables were expressed as counts and percentages. Baseline characteristics between groups were compared using the t test for continuous variables and the chi-square test for categorical variables. Kaplan-Meier analysis was performed to estimate survival over time. Statistical analysis was performed with STATISTICA 10.0 (StatSoft, Tulsa, OK, USA). A two-sided p-value <0.05 was considered statistically significant.
Results
Patients baseline characteristics are summarized in Table 1. The mean CHADS2-score was 1.8 ± 1.0, mean CHA2DS2-VASc score 2.9 ± 1.6 and HAS-BLED score 3.1 ± 1.1. Prior to the procedure 85.6% patients were taking VKA, 12.2% an antiplatelet agent and 2.2% received no anticoagulation.
Procedure related adverse events was noted in 3 (2.1%) cases. Two patients had a right ventricle puncture requiring drainage and observation resolved without cardiac surgery intervention. One patient developed a pericardial effusion during transseptal puncture due to superficial epigastric artery laceration requiring cauterization.
Total follow-up was 428.4 patient-years. During the study period, the average annual thromboembolic event rate was 0.6%: there was one episode of stroke and 2 episodes of thrombus in the LA (which resolved with unfractionated heparin with no further complications). The annual rate of severe bleeding complications was 0.8%: three episodes of hemorrhagic stroke and one episode of gastrointestinal bleeding. Overall annual mortality rate was 1.63%.
Detailed data are present in Table 2.
Estimated thromboembolic risk reduction and estimated bleeding risk reduction are presented in Fig 1.
Discussion
This study demonstrates that the epidocardial approach for LAAC is safe and effective over long-term observations. We demonstrated significant reductions in the expected rate of stroke, thromboembolism and bleeding complications following LAAC for patients with AF.
Current ESC [1] and ACC/AHA/HRS [17] guidelines recommend OAC for stroke and thromboembolic prevention (class IA recommendation) in patients with AF and prior stroke or CHA2DS2-VASc scores ≤ 2. However, there is a large group of patients in whom OAC therapy is contraindicated or ineffective [1,17] or in whom OAC present fatal complications observed that are observed also in new oral anticoagulants[18]. In recent years LAAC has become an increasingly popular alternative [19–21]. ESC guidelines now include LAAC as a Class 2 B recommendation for patients with AF with a contraindication to OAC or a clinical history of severe bleeding [1]. Some cardiology associations are also starting to expand LAAC indications to include patients in whom OAC is ineffective [2].
The short-term safety and efficacy of the Lariat device has been demonstrated for diverse patient groups [7–10,12]. However, long term data regarding epicardial LAAC devices is limited.
In our patients the annual rate of stroke/TIA was 0.2% (one episode over 5 years). In similar 5-year follow-up studies the PREVAIL and PROTECT AF trials quoted a stroke rate of 1.7% for the Watchman device [22] and the PLAATO study reported 3.8% [5]. Although these numbers seem to favor the epicardial approach, we note that the mean CHADS2-score and CHA2DS2—VASc scores in this study were lower than in the endocardial study populations [5,22].
In this study we have demonstrated an 81.3% reduction in the expected rate of thromboembolic events. In the literature, there are only short-term observation study for stroke risk reduction after LAAC with endocardial devices. 1-year follow-up data of the EWOLUTION trail for Watchman device report 84% risk reduction for stroke prevention which is comparable with our results which present over 5 years observation [23]. In our opinion, due to the lack of randomized clinical trials in patients contraindicated for LAAO procedure, presented method of calculated risk reduction to the expected rate based on CHA2DS2-VASc score in the absence of stroke prevention therapy in this population seems to be a reasonable and comparable solution for evaluating the effectiveness of LAAC therapy.
We also calculated a 78.4% reduction in bleeding risk compared to HAS-BLEED predictions. In mentioned short-term results of EWOLUTION trail, the calculated bleeding risk reduction was 54% for Watchman device and was lower compared to our results[23]. However, it is difficult to accurately interpret this result. In contrast to an endocardial devices as the Watchman or the Amulet, epicardial exclusion with the Lariat uses a percutaneous approach to achieve suture closure of the LAA and leaves no foreign body inside left atrium [9,24]. In endocardial devices, the highest risk of thromboembolic events in the first 6 weeks post-procedure therefore VKA is recommended for 45 days after procedure, dual dual antiplatelet therapy for 6 months and aspirin thereafter [25,26]. After epicardial LAAC with Lariat permanent closure of the LAA is observed [24] therefore anticoagulation regimen is life-long aspirin treatment alone. Therefore our recommendation of aspirin monotherapy differs from the standard protocols following endocardial procedures [25,26]
It should be also mentioned, besides thromboembolic and bleeding risk reduction, epicardial LAAO present also hemodynamics and neurohormonal benefits [9,27]. In contrast to endocardial devices, after LAAO using epicardial access with the Lariat, there were significant increases in adiponectin and insulin, with decreased free fatty acids at 3 months post-procedure [27]. Additionally, N-terminal pro-A-type natriuretic peptide and N-terminal pro-B-type natriuretic peptide are significantly decreased in the acute phase after epicardial LAA device implantation, which subsequently normalized at 3 months [9,27]. Post endocardial LAA device implantation, the levels increased immediately and normalized after 24 h [27]. Additionally, with Lariat device there is a possibility to perform post LAAC ablation procedure.
Early experience with the Lariat procedure in some centers was associated with higher complication rates, related to epicardial access. It is important to notice that these findings were with early experience of the 1st generation Lariat procedure. The majority of procedures were performed with a large bore needle for pericardial access and no prophylactic use of colchicine. However, modification of the initial technique in Europe and also in the U.S.[6,28] to deploy a micropuncture needle and prophylactic colchicine has improved the safety profile of this device dramatically. The device itself has also been modified. The second generation of Lariat+ had larger snare accommodating LAA diameters up to 45 mm, steel braided shaft provides increased columnar strength within the shaft allowing it to overcome any influence of the epicardial sheath and distal marker of LARIAT for easy detection of correct orientation under fluoroscopy.
Our initial experiences with Lariat + devices showed 100% successful rate of complete LAA closure without any device or procedural related complications[29]. Comparable results of Lariat+ were also reported from other center with less experience with epicardial devices[30].
Analysis of the FDA MAUDE databases between May 2009 and May 2016 [31] has shown that LAAO was performed by the LARIAT approach in 4,889 cases. WATCHMAN was implanted in 2,027 patients prior to FDA approval in March 2015 and 3,822 patients post-approval. The composite outcome of stroke/TIA, pericardiocentesis, cardiac surgery, and death occurred more frequently with WATCHMAN (cumulative incidence, 1.93% vs. 1.15%; P = 0.001). Similar findings were observed for device embolization, cardiac surgery, and myocardial infarction. Our findings of an overall mortality rate of 1.63% confirm this as a safe procedure over long-term follow-up. However, analysis of the FDA MAUDE databases present some limitations. There was no comparison of patients profile, comorbidities, age, indications for LAA procedure, the risk of stroke or bleeding which may impact of obtained results.
Conclusions
LAAC via an epicardial approach with the Lariat device is a safe and effective treatment in the management of AF patients; 5-year follow-up data shows a reduction in the calculated risk of stroke, thromboembolism and bleeding.
Study limitations
This is a non-randomized, prospective, observational single center study with its inherent limitations. The major limitation for estimating the benefit of LAAC is the lack of a control group and relying on calculated stroke or bleeding risks for analysis. Only the first generation of Lariat devices were studied. Post-procedure anticoagulation was variable. This variability will have had an impact on thromboembolic and bleeding risk, and therefore our calculations of risk reduction.
References
- 1. Camm AJ, Lip GY, De Caterina R, Savelieva I, Atar D, et al. (2012) 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association. Eur Heart J 33: 2719–2747. pmid:22922413
- 2. Grygier M, Wojakowski W, Smolka G, Demkow M, Wasek W, et al. (2018) [Left atrial appendage occlusion: consensus document of Association of Cardiovascular Interventions and Heart Rhythm Section of Polish Cardiac Society]. Kardiol Pol 76: 677–697. pmid:29441512
- 3. Pillarisetti J, Reddy YM, Gunda S, Swarup V, Lee R, et al. (2015) Endocardial (Watchman) vs epicardial (Lariat) left atrial appendage exclusion devices: Understanding the differences in the location and type of leaks and their clinical implications. Heart Rhythm 12: 1501–1507. pmid:25778430
- 4. Wiebe J, Franke J, Lehn K, Hofmann I, Vaskelyte L, et al. (2015) Percutaneous Left Atrial Appendage Closure With the Watchman Device: Long-Term Results Up to 5 Years. JACC Cardiovasc Interv 8: 1915–1921. pmid:26738659
- 5. Block PC, Burstein S, Casale PN, Kramer PH, Teirstein P, et al. (2009) Percutaneous left atrial appendage occlusion for patients in atrial fibrillation suboptimal for warfarin therapy: 5-year results of the PLAATO (Percutaneous Left Atrial Appendage Transcatheter Occlusion) Study. JACC Cardiovasc Interv 2: 594–600. pmid:19628179
- 6. Lakkireddy D, Afzal MR, Lee RJ, Nagaraj H, Tschopp D, et al. (2016) Short and long-term outcomes of percutaneous left atrial appendage suture ligation: Results from a US multicenter evaluation. Heart Rhythm 13: 1030–1036. pmid:26872554
- 7. Bartus K, Bednarek J, Myc J, Kapelak B, Sadowski J, et al. (2011) Feasibility of closed-chest ligation of the left atrial appendage in humans. Heart Rhythm 8: 188–193. pmid:21050893
- 8. Bartus K, Han FT, Bednarek J, Myc J, Kapelak B, et al. (2013) Percutaneous left atrial appendage suture ligation using the LARIAT device in patients with atrial fibrillation: initial clinical experience. J Am Coll Cardiol 62: 108–118. pmid:23062528
- 9. Bartus K, Podolec J, Lee RJ, Kapelak B, Sadowski J, et al. (2017) Atrial natriuretic peptide and brain natriuretic peptide changes after epicardial percutaneous left atrial appendage suture ligation using LARIAT device. J Physiol Pharmacol 68: 117–123. pmid:28456775
- 10. Litwinowicz R, Bartus M, Ceranowicz P, Kapelak B, Lakkireddy D, et al. (2018) Stroke risk reduction after LAA occlusion in elderly patients with atrial fibrillation: long-term results. Pol Arch Intern Med.
- 11. Tzikas A, Holmes DR, Gafoor S, Ruiz CE, Blomström-Lundqvist C, et al. (2017) Percutaneous left atrial appendage occlusion: the Munich consensus document on definitions, endpoints, and data collection requirements for clinical studies. Europace 19: 4–15. pmid:27540038
- 12. Litwinowicz R, Bartus M, Ceranowicz P, Kapelak B, Lakkireddy D, et al. (2018) Stroke risk reduction after left atrial appendage occlusion in elderly patients with atrial fibrillation: longterm results. Pol Arch Intern Med 128: 327–329. pmid:29768394
- 13. Freixa X, Gafoor S, Regueiro A, Cruz-Gonzalez I, Shakir S, et al. (2016) Comparison of Efficacy and Safety of Left Atrial Appendage Occlusion in Patients Aged <75 to >/ = 75 Years. Am J Cardiol 117: 84–90. pmid:26552507
- 14. January CT, Wann LS, Alpert JS, Calkins H, Cigarroa JE, et al. (2014) 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the Heart Rhythm Society. Circulation 130: 2071–2104. pmid:24682348
- 15. Melgaard L, Gorst-Rasmussen A, Lane DA, Rasmussen LH, Larsen TB, et al. (2015) Assessment of the CHA2DS2-VASc Score in Predicting Ischemic Stroke, Thromboembolism, and Death in Patients With Heart Failure With and Without Atrial Fibrillation. Jama 314: 1030–1038. pmid:26318604
- 16. Lip GY, Frison L, Halperin JL, Lane DA (2011) Comparative validation of a novel risk score for predicting bleeding risk in anticoagulated patients with atrial fibrillation: the HAS-BLED (Hypertension, Abnormal Renal/Liver Function, Stroke, Bleeding History or Predisposition, Labile INR, Elderly, Drugs/Alcohol Concomitantly) score. J Am Coll Cardiol 57: 173–180. pmid:21111555
- 17. January CT, Wann LS, Alpert JS, Calkins H, Cigarroa JE, et al. (2014) 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol 64: e1–76. pmid:24685669
- 18. Litwinowicz R, Konstanty-Kalandyk J, Goralczyk T, Bartus K, Mazur P (2018) Dabigatran level monitoring prior to idarucizumab administration in patients requiring emergent cardiac surgery. 45: 9–12. pmid:29222699
- 19. Baman JR, Mansour M, Heist EK, Huang DT, Biton Y (2018) Percutaneous left atrial appendage occlusion in the prevention of stroke in atrial fibrillation: a systematic review. Heart Fail Rev 23: 191–208. pmid:29453694
- 20. Bartuś K (2017) Left atrial appendage occlusion procedures. Kardiochir Torakochirurgia Pol 14: 1–4. pmid:28515740
- 21. Litwinowicz R, Witowski J, Sitkowski M, Filip G, Bochenek M, et al. (2018) Applications of low-cost 3D printing in left atrial appendage closure using epicardial approaches–initial clinical experience. Kardiochirurgia i Torakochirurgia Polska/Polish Journal of Thoracic and Cardiovascular Surgery 15: 135–140.
- 22. Reddy VY, Doshi SK, Kar S, Gibson DN, Price MJ, et al. (2017) 5-Year Outcomes After Left Atrial Appendage Closure: From the PREVAIL and PROTECT AF Trials. J Am Coll Cardiol 70: 2964–2975. pmid:29103847
- 23. Boersma LV, Ince H, Kische S, Pokushalov E, Schmitz T, et al. (2017) Efficacy and safety of left atrial appendage closure with WATCHMAN in patients with or without contraindication to oral anticoagulation: 1-Year follow-up outcome data of the EWOLUTION trial. Heart Rhythm 14: 1302–1308. pmid:28577840
- 24. Bartus K, Morelli RL, Szczepanski W, Kapelak B, Sadowski J, et al. (2014) Anatomic analysis of the left atrial appendage after closure with the LARIAT device. Circ Arrhythm Electrophysiol 7: 764–767. pmid:25140024
- 25. Holmes DR Jr., Kar S, Price MJ, Whisenant B, Sievert H, et al. (2014) Prospective randomized evaluation of the Watchman Left Atrial Appendage Closure device in patients with atrial fibrillation versus long-term warfarin therapy: the PREVAIL trial. J Am Coll Cardiol 64: 1–12. pmid:24998121
- 26. Holmes DR, Reddy VY, Turi ZG, Doshi SK, Sievert H, et al. (2009) Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. Lancet 374: 534–542. pmid:19683639
- 27. Lakkireddy D, Turagam M, Afzal MR, Rajasingh J, Atkins D, et al. (2018) Left Atrial Appendage Closure and Systemic Homeostasis: The LAA HOMEOSTASIS Study. J Am Coll Cardiol 71: 135–144. pmid:29325636
- 28. Betts TR, Leo M, Panikker S, Kanagaratnam P, Koa-Wing M, et al. (2017) Percutaneous left atrial appendage occlusion using different technologies in the United Kingdom: A multicenter registry. Catheter Cardiovasc Interv 89: 484–492. pmid:27651124
- 29. Bartus K, Gafoor S, Tschopp D, Foran JP, Tilz R, et al. (2016) Left atrial appendage ligation with the next generation LARIAT(+) suture delivery device: Early clinical experience. Int J Cardiol 215: 244–247. pmid:27128539
- 30. Fink T, Schluter M, Tilz RR, Heeger CH, Lemes C, et al. (2018) Acute and long-term outcomes of epicardial left atrial appendage ligation with the second-generation LARIAT device: a high-volume electrophysiology center experience. Clin Res Cardiol.
- 31. Jazayeri MA, Vuddanda V, Turagam MK, Parikh V, Lavu M, et al. (2018) Safety profiles of percutaneous left atrial appendage closure devices: An analysis of the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database from 2009 to 2016. 29: 5–13.