Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Assessing the use of a micro-sampling device for measuring blood protein levels in healthy subjects and COVID-19 patients

  • Joost Brandsma ,

    Roles Conceptualization, Data curation, Formal analysis, Methodology, Resources, Visualization, Writing – original draft, Writing – review & editing

    JBrandsma@aceso-sepsis.org

    Affiliation Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America

  • Josh G. Chenoweth,

    Roles Conceptualization, Investigation, Project administration, Supervision, Writing – review & editing

    Affiliation Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America

  • Melissa K. Gregory,

    Roles Investigation, Resources

    Affiliation Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America

  • Subramaniam Krishnan,

    Roles Conceptualization, Writing – review & editing

    Affiliation Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America

  • Paul W. Blair,

    Roles Conceptualization, Investigation, Writing – review & editing

    Affiliations Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America, Department of Pathology, School of Medicine, Uniformed Services University, Bethesda, Maryland, United States of America

  • Deborah A. Striegel,

    Roles Data curation, Formal analysis, Methodology, Resources

    Affiliation Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America

  • Rittal Mehta,

    Roles Formal analysis, Methodology

    Affiliation Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America

  • Kevin L. Schully,

    Roles Conceptualization, Writing – review & editing

    Affiliation Austere Environments Consortium for Enhanced Sepsis Outcomes, Biological Defense Research Directorate, Naval Medical Research Center-Frederick, Frederick, Maryland, United States of America

  • J. Stephen Dumler,

    Roles Investigation, Writing – review & editing

    Affiliation Department of Pathology, School of Medicine, Uniformed Services University, Bethesda, Maryland, United States of America

  • CDR Cynthia S. Sikorski,

    Roles Project administration, Supervision, Writing – review & editing

    Affiliation Naval Health Research Center, San Diego, California, United States of America

  • Kelsey O’Connor,

    Roles Data curation, Resources

    Affiliations Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America, Tripler Army Medical Center, Honolulu, Hawaii, United States of America

  • Susan A. Reichert-Scrivner,

    Roles Data curation, Resources

    Affiliations Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America, Tripler Army Medical Center, Honolulu, Hawaii, United States of America

  • Carmen M. Paguirigan,

    Roles Data curation, Resources

    Affiliation Tripler Army Medical Center, Honolulu, Hawaii, United States of America

  • Catherine F. T. Uyehara,

    Roles Resources, Writing – review & editing

    Affiliation Tripler Army Medical Center, Honolulu, Hawaii, United States of America

  • COL Viseth Ngauy,

    Roles Funding acquisition, Project administration, Supervision, Writing – review & editing

    Affiliation Tripler Army Medical Center, Honolulu, Hawaii, United States of America

  • Christopher A. Myers,

    Roles Funding acquisition, Project administration, Supervision

    Affiliation Naval Health Research Center, San Diego, California, United States of America

  •  [ ... ],
  • Danielle V. Clark

    Roles Conceptualization, Funding acquisition, Project administration, Supervision, Writing – review & editing

    Affiliation Austere Environments Consortium for Enhanced Sepsis Outcomes, Henry M. Jackson Foundation for the Advancement of Military Medicine Inc., Bethesda, Maryland, United States of America

  • [ view all ]
  • [ view less ]

Abstract

Background

Venous phlebotomy performed by trained personnel is critical for patient diagnosis and monitoring of chronic disease, but has limitations in resource-constrained settings, and represents an infection control challenge during outbreaks. Self-collection devices have the potential to shift phlebotomy closer to the point of care, supporting telemedicine strategies and virtual clinical trials. Here we assess a capillary blood micro-sampling device, the Tasso Serum Separator Tube (SST), for measuring blood protein levels in healthy subjects and non-hospitalized COVID-19 patients.

Methods

57 healthy controls and 56 participants with mild/moderate COVID-19 were recruited at two U.S. military healthcare facilities. Healthy controls donated Tasso SST capillary serum, venous plasma and venous serum samples at multiple time points, while COVID-19 patients donated a single Tasso SST serum sample at enrolment. Concentrations of 17 protein inflammatory biomarkers were measured in all biospecimens by Ella multi-analyte immune-assay.

Results

Tasso SST serum protein measurements in healthy control subjects were highly reproducible, but their agreements with matched venous samples varied. Most of the selected proteins, including CRP, Ferritin, IL-6 and PCT, were well-correlated between Tasso SST and venous serum with little sample type bias, but concentrations of D-dimer, IL-1B and IL-1Ra were not. Self-collection at home with delayed sample processing was associated with significant concentrations differences for several analytes compared to supervised, in-clinic collection with rapid processing. Finally, Tasso SST serum protein concentrations were significantly elevated in in non-hospitalized COVID-19 patients compared with healthy controls.

Conclusions

Self-collection of capillary blood with micro-sampling devices provides an attractive alternative to routine phlebotomy. However, concentrations of certain analytes may differ significantly from those in venous samples, and factors including user proficiency, temperature control and time lags between specimen collection and processing need to be considered for their effect on sample quality and reproducibility.

Introduction

Blood molecular biomarkers are critical for patient diagnosis, prognosis and monitoring of chronic disease. The “gold standard” method of blood collection is venous phlebotomy, but this is subject to certain limitations and potential complications, including availability of trained personnel, patients needing to travel to a central location, fear of needles, vasovagal responses, and phlebotomist exposure to potentially infectious bodily fluids or other transmissible infections. Deployment of self-collection devices for blood micro-sampling overcomes most of these limitations, shifting disease diagnosis and population monitoring closer to the point-of-care [1]. These technologies have the potential to revolutionize health care delivery by supporting telehealth visits and virtual clinical trials, providing conveniences to the patient and enabling outreach to remote populations. Additionally, self-collection devices can facilitate the rapid collection of blood during mass population visits, for example during medical in-processing at military recruitment accession sites.

While the U.S. Food and Drug Administration (FDA) in 2018 recommended comparison studies between venous blood and micro-samples of capillary blood, few such studies have been conducted to date [2, 3]. As a consequence, challenges remain in integrating results obtained using either sampling approach. Here we present a direct comparison between capillary blood micro-sampling and routine venous phlebotomy for protein biomarker analysis in an outpatient setting, and within the context of enabling virtual clinical trials for SARS-CoV-2 and other diseases.

The Tasso Serum Separator Tube (SST) (Tasso Inc., WA, USA) is a single-use, sterile, disposable, integrated device for self-collection of capillary blood by the user [4]. It is classified as an FDA 510(k) Class 2 device when used for a specific diagnostic panel, but is otherwise for investigational use only (IUO). The device comprises a lancet assembly and a detachable reservoir collection unit (called Tasso Button), designed to collect up to 300 μL capillary blood that can be processed to generate serum at a central processing lab for downstream analysis [57]. We quantified 17 protein inflammatory biomarkers in Tasso SST capillary serum and phlebotomy samples (venous serum and plasma), obtained from healthy subjects and non-hospitalized COVID-19 patients recruited at two U.S. military healthcare facilities. The inflammatory biomarkers were selected from previously published immune signatures in COVID-19 or sepsis [8], or based on their clinical use in the management of COVID-19 [9]. Using matched samples, our primary aim was to assess the utility of capillary blood micro-sampling as an alternative to routine phlebotomy. Our secondary aim was to examine the impact of unsupervised self-collection at home with the Tasso SST device, versus supervised collection and rapid processing in the clinic. Finally, we demonstrate the utility of blood self-sampling for telemedicine by testing whether the Tasso SST serum protein biomarkers differed significantly between non-hospitalized mild/moderate COVID-19 patients and healthy controls.

Materials and methods

113 participants were enrolled under the PROMETHEUS 2.0 protocol between April 2020 and January 2021 at two U.S. military healthcare facilities: Tripler Army Medical Center in Honolulu, Hawaii (TAMC) and the Naval Health Research Centre in San Diego, California (NHRC) (S1 Table). Informed consent and/or assent was received from all participants before enrolment was completed. While written, paper-based consent was available for use, due to the contagious nature of emergent infectious diseases being studied, study staff were not always able to collect in-person consent from potential participants. In such cases, an electronic version with an alteration of the informed consent was utilized. For participants between 13–17 years of age, participant assent and parental/guardian consent was obtained. Participant COVID-19 status was established by RT-PCR test prior to enrolment, and subsequently monitored by either further RT-PCR tests or GeneXpert Xpress SARS-CoV-2 tests (Cepheid, Sunnyvale, CA, USA) of nasopharyngeal swabs collected throughout the study (up to five swabs in total, coinciding with the blood collection). All healthy controls were considered high-risk for contracting COVID-19 due to their profession or otherwise close proximity to COVID-19 patients (e.g., healthcare workers, family members).

Forty-two (42) healthy controls recruited at TAMC donated up to 5 matched samples of venous serum (clot-activator vacutainer), venous plasma (K2EDTA), and capillary blood (Tasso SST), at 0, 3-, 7-, 14- and 28-days post-enrolment (Fig 1). These samples were collected under supervision at the clinic and processed the same day, allowing for a direct comparison between the three sample types. Fifteen (15) healthy controls recruited at NHRC self-collected up to 5 capillary blood samples (Tasso SST) at home on the same study time points. These samples were sent from the participants’ home address to the NHRC lab by FedEx Priority Overnight in insulated containers with an ice pack, with transit times ranging from 0–5 days (median 2 days). Thus, the study design allowed for comparison of Tasso SST specimens processed shortly after supervised collection versus self-collected specimens with potentially delayed processing, albeit with unmatched samples. Median collection volumes for the Tasso SST after serum processing were 112 μl and 120 μl for the at-home and in-clinic collections, respectively, and recorded incidences of device failures and sample haemolysis were both very low (<1%).

thumbnail
Fig 1. Flow chart of the samples collected at each site, the sampling location (unsupervised self-collection at home, or supervised collection in-clinic), and method of transport to the central processing labs.

TAMC: Tripler Army Medical Center; NHRC: Naval Health Research Center.

https://doi.org/10.1371/journal.pone.0272572.g001

Fifty-six (56) participants tested positive for SARS-CoV-2 at enrolment (24 TAMC and 32 NHRC), and 1 of the TAMC healthy controls contracted COVID-19 partway through the study, thus switching study arms (Fig 1). These COVID-19 patients self-isolated at home and collected a capillary blood sample (Tasso SST) at enrolment or on day-0 of study arm reassignment (n = 57). TAMC samples were sent cold (4°C) by rapid courier service directly to the specimen processing site (total transit time 0–3 days, median 1 day), while the NHRC samples were again sent with an ice pack by regular courier (total transit time 0–7 days, median 2 days).

A panel of 17 protein biomarkers of inflammation was measured in triplicate in all samples using the Ella multi-analyte immuno-assay (ProteinSimple, San Jose, CA, USA). Concentrations of CD163, CRP, CXCL10, D-dimer, Ferritin, ICAM-1, IL-1B, IL-1Ra, IL-5, IL-6, IL-6Ra, IL-18BPa, LCN, PCT, RAGE, TNF-R1 and VEGF-A were log10-transformed, and any measurements below the lower limit of detection (LLoD) of the Ella platform were imputed using the lowest measured value for that particular analyte. This only affected IL-1B and IL-5 (40% and 14% imputation, respectively). Eight percent (8%) of the D-dimer measurements were above the upper limit of detection (ULoD) for the assay, and these were imputed using the highest measured value for D-dimer. Finally, a small amount of missing data (<1% for any given analyte) was imputed using a k-nearest neighbour algorithm in Python (“sklearn” package version 0.24.2, k = 4). Protein concentrations and supporting data used in this study are provided in the Supplementary Information.

All plots and statistics were generated in R (version 3.6.3) using the “ggpubr” package (version 0.4.0). Unless otherwise stated, the n reported in the tables and figures refers to individual samples (up to 5 per subject). Comparisons across multiple groups were done by Kruskal-Wallis test, and comparisons between two specific groups using the Mann–Whitney U test (adjusted q-values are reported). Scatter plots were fitted with a simple linear regression, and we report the Pearson correlation coefficient of determination (R2). Fixed bias in the Bland-Altman plots was assessed by paired t-test.

Results

Reproducibility of the Tasso SST assay was assessed by calculating the coefficient of variation (CV) for each protein between the study time points of each healthy control subject, and determining the median and range. Irrespective of sampling and shipment protocol, we found excellent reproducibility (median CV <5%) for most of the tested analytes. Exceptions were IL-1B (median CV 79%), IL-5 (median CV 47%), and IL-6 (median CV 63%), all of which were at the lower limit of the Ella platform’s dynamic range in these healthy subjects.

Protein concentrations in Tasso SST serum samples from the TAMC healthy controls (supervised, in-clinic collection) were compared to those in matched venous serum and plasma samples (Table 1; S1 Fig). For this comparison, samples from all study time points were used to cover the full baseline concentration range in a non-diseased population. Protein concentrations were comparable across all three sample types for CD163, CRP, ICAM-1, IL-6, IL-6Ra, IL-18BPa, PCT and RAGE. Levels of CXCL10, Ferritin, IL-1Ra, TNF-R1 and VEGF-A were significantly higher in Tasso SST serum samples than in both venous serum and plasma. IL-5 and LCN concentrations were comparable in both serum types, but significantly different in venous plasma. In contrast, levels of D-dimer and IL-1Ra were comparable for Tasso SST serum and venous plasma, but significantly lower in venous serum. For each of the tested analytes, concentrations in capillary serum sampled by Tasso SST were equal to or higher than those found in venous serum.

thumbnail
Table 1. Comparison of protein concentrations from peripheral blood samples of 42 TAMC healthy controls obtained in-clinic using the Tasso SST (capillary serum) and phlebotomy (venous serum and plasma).

Up to 5 samples were collected from each participant over a 28-day period and are aggregated here. Concentrations are given as the median and interquartile range, and sorted by adjusted Kruskal-Wallis test q-values. *Note the high proportion of samples with IL-1B and IL-5 concentrations below the LLoQ. Boxplots of individual proteins with between-group significance are given in S1 Fig.

https://doi.org/10.1371/journal.pone.0272572.t001

Using the matched sample set from TAMC healthy controls, we also assessed whether protein concentrations were correlated between the three sample types (selected plots shown in Fig 2; see S2 Table and S2 Fig for the full results). Most of the tested analytes had either excellent (R2>0.9) or good (R2 = 0.6–0.9) correlations across all sample types, including CD163, CRP, CXCL10, Ferritin, ICAM-1, IL-6, IL-6Ra, IL-18BPa, PCT, RAGE and TNF-R1. Correlations for IL-5, LCN and VEGF-A were moderate (R2 = 0.4–0.6), not just for the comparison between Tasso SST serum and venous samples, but also when comparing matched venous serum and plasma. Finally, there was no correlation (R2<0.2) for D-dimer, IL-1B and IL-1Ra, although only IL-1B was also poorly correlated between venous serum and plasma. Bland-Altman plots showed only minor fixed biases between sample types for most of the analytes (S2 Table and S3 Fig). Exceptions were the analytes at the low end of the Ella platform’s dynamic range (IL-1B, IL-5 and IL-6), as well as a bias towards Tasso SST serum for IL-1Ra, and towards either serum type for VEGF-A and CXCL10.

thumbnail
Fig 2. Correlation of selected protein concentrations in matched peripheral blood samples of 42 TAMC healthy controls obtained in-clinic using the Tasso SST (capillary serum) and phlebotomy (venous serum).

Up to 5 samples were collected from each participant over a 28-day period and are aggregated here. Concentrations were log10 transformed. Scatter plots were fitted with a simple linear regression (solid blue line), and the Pearson correlation R and p values are shown. Ella assay limits of detection are show with the dashed lines (blue: LLoD; red: ULoD).

https://doi.org/10.1371/journal.pone.0272572.g002

Protein concentrations in the Tasso SST serum of healthy controls were compared between those with supervised, in-clinic collection and prompt specimen processing (TAMC; 196 samples from 42 subjects), and those with self-collection at home and delayed specimen processing due to longer transit times (NHRC; 44 samples from 15 subjects). Levels of D-dimer, IL-1B, IL-1Ra, IL-5, IL-6Ra, LCN and PCT were all significantly different in samples from the two protocols, and particularly D-dimer and IL-1B had much higher median concentrations in the self-collected samples (Table 2). Levels of CXCL10, ICAM-1 and IL-18BPa were also significantly different in the self-collected samples, but the concentration ranges for these analytes were comparable for both protocols, and we note the small sample size for the self-collected group (NHRC).

thumbnail
Table 2. Concentrations of selected proteins in Tasso SST serum samples from healthy controls recruited at TAMC (supervised collection in-clinic with prompt processing) and NHRC (at-home self-collection with delayed processing).

Up to 5 samples were collected from each subject over a 28-day period and are aggregated here. Concentrations are given as the median and interquartile range, with Mann-Whitney U test q-values for comparing the two sites. *Note the high proportion of at-home, self-collected samples with D-dimer concentrations above the ULoQ.

https://doi.org/10.1371/journal.pone.0272572.t002

We compared Tasso SST serum protein concentrations at baseline (day-0) of 48 healthy controls and 57 mild/moderate COVID-19 patients (all biospecimens were self-collected at-home, but with delayed processing for the 32 NHRC samples). The median duration between date of infection (first confirmed COVID-19 RT-PCR result) and baseline sampling was 5 days (range 0–16 days). Concentrations of CD163, CRP, CXCL10, D-dimer, Ferritin, IL-1B, IL-1Ra, IL-6, LCN, TNF-R1 and VEGF-A were all significantly higher in the COVID-positive samples (Table 3). However, increased levels of e.g., D-dimer, IL-1B, IL-1Ra and IL-5 in the healthy control samples that were self-collected at home resulted in different outcomes for the individual sampling protocols (S4 Fig).

thumbnail
Table 3. Baseline concentrations of selected proteins in Tasso SST serum samples from healthy controls and COVID-19 patients (pooled data from both study sites).

Concentrations are given as the median and interquartile range, and sorted by adjusted Mann-Whitney U test q-values. *Note the high proportion of samples with D-dimer concentrations above the ULoQ, particularly in the self-collected protocol (NHRC). Boxplots for each analyte are given in S4 Fig.

https://doi.org/10.1371/journal.pone.0272572.t003

Discussion

Self-collection of blood micro-samples overcomes a number of limitations associated with regular blood collection in-clinic, providing conveniences to the patient and enabling outreach to difficult-to-access populations [2]. By shifting phlebotomy closer to the point of care, devices such as the Tasso SST have an important role to play in the development of telemedicine strategies and conducting virtual clinical trials. Additionally, they can facilitate the rapid collection of blood during mass population visits, such as medical in-processing at military recruit accession sites. Here we assess the Tasso SST, a capillary blood micro-sampling device, for measuring blood protein levels in healthy subjects and mild/moderate COVID-19 patients in an outpatient setting. We show that Tasso SST-collected capillary serum measurements of multiple clinically relevant inflammatory biomarkers, including CRP, Ferritin, IL-6 and PCT, are highly reproducible and correlate well with routine phlebotomy samples (venous serum). Furthermore, we demonstrate that Tasso SST serum protein levels in samples from COVID-19 patients differ significantly from those obtained from healthy controls.

Capillary blood micro-sampling is mostly utilized for neonates and infants, when only small volumes are available or when venous access is difficult, but in adults it is an uncommon method for blood collection. The Tasso SST is classified as an FDA 510(k) Class 2 device when used for a specific diagnostic panel, but otherwise the technology is for investigational use only (IUO). Our primary aim was to assess the reproducibility of Tasso SST serum protein measurements, as well as their agreement with protein levels measured in matched venous serum and plasma samples. High reproducibility is important for any clinically-relevant assay, be it well-established or newly-developed. Repeat sampling of healthy controls over a period of 28 days showed excellent within-subject reproducibility for most of the protein biomarkers. Measurements of IL-1B, IL-5 and IL-6 were more variable, but this could be ascribed to low circulating levels of these analytes in the absence of disease. Protein concentrations in the Tasso SST serum were equal to, or higher than, those measured in matched venous samples. However, the smaller sample volumes obtained using this technology (median 112–120 μL) may be a limiting factor in some study designs. It was further noted that user training and experience with the devices prior to deployment had a positive impact on sample yield, and that users preferred this technology to devices that use fingersticks (VN, personal observations).

The reasons for the observed concentration differences between capillary and venous serum samples are not entirely clear, since we were unable to ascertain whether there are location-specific differences in healthy adults due to a paucity of comparative proteomics measurements [4]. Prior studies have found that capillary and venous blood differ significantly in their haematological measurements, cell counts, and coagulation factors [10, 11], as well as the levels of some specific protein biomarkers (e.g., S100B for intracranial haemorrhage) [12]. Hence, it stands to reason that several of the analytes included in our inflammatory protein panel would differ as well. Our results suggest that baseline levels of D-dimer, IL-1Ra, Ferritin, TNF-R1 and VEGF-A are higher in the capillary serum of healthy adults than in venous serum. Future work may validate these observations, or expand on them by performing a more comprehensive proteomic analysis.

Substituting one sampling method or biospecimen type for another requires a high level of agreement between the two, ideally in the form of a linear relationship between the analyte yields over a wide range of concentrations. Most of the tested proteins showed good to excellent correlations between Tasso SST serum and venous serum with little sample type bias (S2 Table). This included acute phase reactant biomarkers in current clinical use, such as CRP, ferritin, and PCT. In contrast, the lack of any correlation in D-dimer and IL-1Ra measurements makes Tasso SST-derived measurements not useful as a direct correlate of phlebotomy samples for those analytes, although it remains possible that they follow comparable trends over time during an inflammatory response to infection. Accurate agreement levels for IL-1B, IL-5 and IL-6 were difficult to establish due to their low concentrations. These analytes may turn out to be well-correlated in patients with an ongoing inflammatory response, and moderate correlations observed for some of the other analytes could likewise improve with the inclusion of samples with elevated inflammatory protein levels (e.g., LCN, VEGF-A, TNF-R1). Our results show that protein levels in self-collected samples from devices like the Tasso SST may differ from those in routine phlebotomy samples, and that normal value ranges for analytes in capillary micro-samples may need to be redefined for clinical use.

Assay reproducibility can be a significant challenge in serum cytokine analysis, in particular when comparing sample handling protocols that are employed at individual sites or for different studies [13]. We therefore examined whether unsupervised self-collection at home with potentially delayed biospecimen processing (healthy controls recruited at NHRC) impacted analyte concentrations, using the supervised in-clinic collection and rapid processing at the TAMC site as a reference. Concentrations of D-dimer, IL-1B, IL-1Ra, IL-5, IL-6Ra, LCN and PCT were all significantly different in the self-collected samples, suggesting they were potentially affected by factors such as user proficiency with the device, temperature during storage and shipping, or transit times. We note that the relatively small sample size of the self-collected group (44 samples from 15 NHRC healthy controls) may have contributed to the observed differences (e.g., CXCL10, ICAM-1 and IL-18BPa), and that we did not control for potential demographic differences between the two study sites. Given the high within-patient reproducibility in this study, it is unlikely that the observed differences between NHRC and TAMC samples were caused by the way Tasso devices were applied and handled by individual participants. Sample transit times were recorded, but protein concentrations did not show significant associations with delays in sample processing (linear regression or Jonckheere-Terpstra test for categorized data). Unfortunately, the study design did not allow for further, more in-depth assessment of assay reproducibility under a controlled set of real-life conditions. Future biomarker studies involving micro-sampling devices should build on our results and are recommended to include rigorous, analyte-specific reproducibility testing and validation prior to enrolment. Because of the unique sampling technology involved, as well as the potential differences between venous and capillary blood, such testing will ideally be performed with actual devices, rather than on bulk commercial blood products. This will ensure selection of analytes that are robust to differences in sample handling protocols, as well as variable environmental conditions and user proficiency.

To demonstrate the clinical utility of blood self-sampling for telemedicine (e.g., virtual clinical trials, distributed medicine), we tested whether the Tasso SST serum protein biomarkers could distinguish COVID-19 patients from healthy controls in a cross-sectional manner. Although none of the COVID-19 cases enrolled in this study were severe enough to require hospitalization, their Tasso SST serum contained significantly elevated levels of a range of protein biomarkers. These results are in line with the published literature on COVID-19 [8, 1420] and inflammatory markers in general (e.g., CRP, Ferritin, D-dimer), although we acknowledge that the COVID-19 patients were recruited from a diverse demographic at two different sites, and included a range of disease stages (days after onset) and severities. Ongoing work by our group includes mapping the longitudinal inflammatory responses in these patients using the capillary micro-sampling approach, and how those biomarker patterns can be used to predict clinical outcomes. Cytokines and chemokines are involved in the effector phase of all inflammatory diseases, and many have been implicated in the pathobiology of COVID-19, or proposed as prognostic markers of disease severity or hospital/ICU admission [8, 1420]. As COVID-19 progresses over time, disruption of cellular processes leads to increased biological dissonance, cascading to overt symptoms and a variety of possible disease phenotypes, which depend on the interplay between pathogen and host response [21, 22]. Early detection, diagnosis and treatment of infection have been shown to result in significant reductions in disease severity and mortality, including in COVID-19 [23, 24]. The ability to remotely monitor disease progression after the initial diagnosis, and time interventions accordingly, is likely to yield additional benefits, in particular for high-risk individuals and those early on in the disease when the risk of transmission is highest [21]. In this context, unsupervised self-collection of Tasso SST capillary blood for Anti-SARS-CoV-2 IgG antibody testing, and mid-nasal swabs for detection of SARS-CoV-2 infection have already yielded promising results [25, 26]. In this study, we have demonstrated the utility of remote serum collection with the Tasso SST to enable detection of elevated biomarkers of inflammation in the disease state of COVID-19. In conclusion, continued development of scalable, easy-to-use technologies for at-home biological sampling and testing will permit the rapid triaging of a significant number of individuals to early care, thereby decreasing the disease burden.

Supporting information

S1 Table. Summary demographics of the study cohort.

Gender is shown as the ratio of male (M) to female (F) participants; Age is given as the median and range; Race is shown as the ratio of white (W) to other/non-white (O) participants.

https://doi.org/10.1371/journal.pone.0272572.s001

(PDF)

S2 Table. Protein correlations between sample type.

Agreement and bias for protein concentrations in matched peripheral blood sample types of TAMC healthy controls (supervised, in-clinic collection). The table lists the Linear Model coefficients of determination (Pearson’s R2) and Bland-Altman fixed bias. Where significant according to a paired t-test, the proportional fixed bias (%) is given; note that this exaggerates small apparent bias at low concentration ranges. *Samples with concentrations below the LLoQ were excluded for IL-1B and IL-5, resulting in a reduced sample size. Correlation and Bland-Altman plots for individual proteins are given in S2 and S3 Figs, respectively.

https://doi.org/10.1371/journal.pone.0272572.s002

(PDF)

S1 Data. Study data summary.

Summary table of the data and metadata used in this study, including: Ella protein concentrations (in pg/ml), sample information (sample type and study time point), and selected subject information (sex, race, age, study site and COVID-19 status at the time of sampling).

https://doi.org/10.1371/journal.pone.0272572.s003

(XLSX)

S1 Fig. Boxplots of protein concentrations in different blood sample types from healthy controls.

Comparison of protein concentrations from peripheral blood samples of 42 TAMC healthy controls obtained in-clinic using the Tasso SST (capillary serum) and phlebotomy (venous serum and plasma). Up to 5 samples were collected from each participant over a 28-day period and are aggregated here. Concentrations were log10 transformed. Significance values for Mann-Whitney U tests between sample types are abbreviated as follows: n.s. not significant; * p<0.05; ** p<0.01; *** p<0.001; **** p<0.0001.

https://doi.org/10.1371/journal.pone.0272572.s004

(PDF)

S2 Fig. Correlation of protein concentrations in matched venous and Tasso SST serum samples from healthy controls.

Correlation of protein concentrations in matched peripheral blood samples of 42 TAMC healthy controls obtained in-clinic using the Tasso SST (capillary serum) and phlebotomy (venous serum). Up to 5 samples were collected from each participant over a 28-day period and are aggregated here. Concentrations were log10 transformed. Scatter plots were fitted with a simple linear regression (blue line), and the Pearson correlation R and p values are shown.

https://doi.org/10.1371/journal.pone.0272572.s005

(PDF)

S3 Fig. Agreement and bias of protein concentrations in matched venous and Tasso SST serum samples from healthy controls.

Bland-Altman plots of protein concentrations in matched peripheral blood samples of 42 TAMC healthy controls obtained in-clinic using the Tasso SST (capillary serum) and phlebotomy (venous serum). Up to 5 samples were collected from each participant over a 28-day period and are aggregated here. Concentrations were log10 transformed. Fixed bias in the plots was assessed by paired t-test.

https://doi.org/10.1371/journal.pone.0272572.s006

(PDF)

S4 Fig. Tasso SST protein concentrations in COVID-19 patients and healthy controls.

Baseline concentrations of selected proteins in Tasso SST serum samples from healthy controls and non-hospitalized COVID-19 patients. Data are shown for the supervised, in-clinic collection protocol at TAMC (with rapid processing), the unsupervised, at-home self-collection protocol at NHRC (with potentially delayed processing), and for both protocols combined. Concentrations were log10 transformed. Significance values for Mann-Whitney U tests between COVID-19 patients and healthy controls are abbreviated as follows: n.s. not significant; * p<0.05; ** p<0.01; *** p<0.001; **** p<0.0001.

https://doi.org/10.1371/journal.pone.0272572.s007

(PDF)

Acknowledgments

The authors want to thank the PROMETHEUS study teams at NHRC and TAMC, and colleagues at HJF ACESO, for enabling this study.

Disclaimers

The views expressed in this article reflect the results of research conducted by the author and do not necessarily reflect the official policy or position of the Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., the Department of the Navy, Department of the Army, Department of Defense, nor the United States Government.

CAM, CFTU, JSD, KLS, and VN are military service member or federal employees of the United States government. This work was prepared as part of their official duties. Title 17 U.S.C. 105 provides that “copyright protection under this title is not available for any work of the United States Government.” Title 17 U.S.C. defines a U.S. Government work as work prepared by a military service member or employee of the U.S. Government as part of that person’s official duties.

The study protocol “NHRC protocol.2020.0006 Prometheus” was approved by the Naval Health Research Institutional Review Board in compliance with all applicable federal regulations governing the protection of human subjects.

References

  1. 1. Lei BUW, Prow TW. A review of microsampling techniques and their social impact. Biomed. Microdevices. 2019; 21:81. pmid:31418068
  2. 2. U.S. Food and Drug Administration. Bioanalytical Method Validation. Guidance for Industry (2018). https://www.fda.gov/downloads/drugs/guidances/ucm070107.pdf
  3. 3. Wickremsinhe ER, Ji QI, Gleason CR, Anderson M, Booth BP. Land O’Lakes Workshop on Microsampling: Enabling Broader Adoption. AAPS J. 2020; 22:135. pmid:33098040
  4. 4. https://www.tassoinc.com/tasso-sst
  5. 5. Haack AJ, Yun Lim F, Kennedy DS, et al. homeRNA: A self-sampling kit for the collection of peripheral blood and stabilization of RNA. Anal. Chem. 2021; 93:13196–13203. pmid:34546711
  6. 6. Vusirikala A, Whitaker H, Jones S, et al. Seroprevalence of SARS-CoV-2 antibodies in university students: Cross-sectional study, December 2020, England. J. Infect. 2021; 83:104–111. pmid:33933527
  7. 7. Williams KJ, Lutman J, McCaughey C, Fisher SK. Assessment of low volume sampling technologies: utility in nonclinical and clinical studies. Bioanalysis 2021; 13. pmid:33900106
  8. 8. Covid-19 Multi-omics Blood Atlas (COMBAT) Consortium. A blood atlas of COVID-19 defines hallmarks of disease severity and specificity. Cell 2022; 185(5):916–938.e58. pmid:35216673
  9. 9. Cihakova D, Streiff MB, Menez SP, et al. High-value laboratory testing for hospitalized COVID-19 patients: a review. Future Virol. 2021; 16. pmid:34567235
  10. 10. Kayiran SM, Ozbek N, Turan N, Gürakan B. Significant differences between capillary and venous complete blood counts in the neonatal period. Clin Lab Haematol. 2003; 25(1):9–16. pmid:12542436
  11. 11. Fliervoet LAL, Groenestege WMT, Huisman A. Comparison of capillary and venous blood sampling for routine coagulation assays. J Clin Biochem. 2022 (online access).
  12. 12. Vedin T, Karlsson M, Edelhamre M, Bergenheim M, Larsson P-A. Prospective comparison of capillary and venous brain biomarker S100B: capillary samples have large inter-sample variation and poor correlation with venous samples. Int J Emerg Med. 2019; 12(1):26. pmid:31477027
  13. 13. Wong H-L, Pfeiffer RM, Fears TR, Vermeulen R, Ji S, Rabkin CS. Reproducibility and correlations of multiplex cytokine levels in asymptomatic persons. Cancer Epidemiol. Biomarkers Prev. 2008; 17. pmid:19064561
  14. 14. Del Valle DM, Kim-Schulze S, Huang H-H, et al. An inflammatory cytokine signature predicts COVID-19 severity and survival. Nat Med 2020; 26:1636–1643. pmid:32839624
  15. 15. Herold T, Jurinovic V, Arnreich C, et al. Elevated levels of IL-6 and CRP predict the need for mechanical ventilation in COVID-19. J. Allergy Clin. Immunol. 2020; 146:128–136. pmid:32425269
  16. 16. Tong M, Jiang Y, Xiong Y, et al. Elevated Expression of Serum Endothelial Cell Adhesion Molecules in COVID-19 Patients. J. Infect. Dis. 2020; 222:894–898. pmid:32582936
  17. 17. Meizlish ML, Pine AB, Bishai JD, et al. A neutrophil activation signature predicts critical illness and mortality in COVID-19. Blood Adv. 2021; 5:1164–1177. pmid:33635335
  18. 18. Poudel A, Poudel Y, Adhikari A, et al. D-dimer as a biomarker for assessment of COVID-19 prognosis: D-dimer levels on admission and its role in predicting disease outcome in hospitalized patients with COVID-19. PLoS ONE 2021. pmid:34437642
  19. 19. Mortaz E, Tabarsi P, Jamaati H, et al. Increased Serum Levels of Soluble TNF-α Receptor Is Associated With ICU Mortality in COVID-19 Patients. Front. Immunol. 2021; 12:592727. pmid:33968010
  20. 20. Coperchini F, Chiovato L, Rotondi M. Interleukin-6, CXCL10 and Infiltrating Macrophages in COVID-19-Related Cytokine Storm: Not One for All But All for One! Front. Immunol. 2021; 12:668507. pmid:33981314
  21. 21. Cevik M, Kuppalli K, Kindrachuk J, Peiris M. Virology, transmission, and pathogenesis of SARS-CoV-2. BMJ 2020; 371:m3862. pmid:33097561
  22. 22. Su Y, Chen D, Yuan D, et al. Multi-Omics Resolves a Sharp Disease-State Shift between Mild and Moderate COVID-19. Cell 2021; 183:1479–1495. pmid:33171100
  23. 23. Hotchkiss RS, Moldawer LL, Opal SM, Reinhart K, Turnbull IR, Vincent J-L. Sepsis and septic shock. Nat. Rev. Dis. Primers 2016; 2:16045. pmid:28117397
  24. 24. Goyal DK, Mansab F, Iqbal A, Bhatti S. Early intervention likely improves mortality in COVID-19 infection. Clin. Med. 2020; 20:248–250. pmid:32357975
  25. 25. McCulloch DJ, Kim AE, Wilcox NC, et al. Comparison of Unsupervised Home Self-collected Midnasal Swabs With Clinician-Collected Nasopharyngeal Swabs for Detection of SARS-CoV-2 Infection. JAMA Netw. Open 2020; 3:e2016382 pmid:32697321
  26. 26. Hendelman T, Chaudhary A, LeClair AC, et al. Self-collection of capillary blood using Tasso-SST devices for Anti-SARS-CoV-2 IgG antibody testing. PLoS ONE 2021. pmid:34473717