Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Slaughterhouse Wastewater Treatment by Combined Chemical Coagulation and Electrocoagulation Process

  • Edris Bazrafshan,

    Affiliation Health Promotion Research Center, Zahedan University of Medical Sciences, Zahedan, Iran

  • Ferdos Kord Mostafapour,

    Affiliation Health Promotion Research Center, Zahedan University of Medical Sciences, Zahedan, Iran

  • Mehdi Farzadkia,

    Affiliation School of Public Health, Tehran University of Medical Sciences, Tehran, Iran

  • Kamal Aldin Ownagh,

    Affiliation Health Promotion Research Center, Zahedan University of Medical Sciences, Zahedan, Iran

  • Amir Hossein Mahvi

    ahmahvi@yahoo.com

    Affiliations School of Public Health, Tehran University of Medical Sciences, Tehran, Iran, Center for Solid Waste Research, Institute for Environmental Research, Tehran University of Medical Sciences, Tehran, Iran, National Institute of Health Research, Tehran University of Medical Sciences, Tehran, Iran

Abstract

Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD5 removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.

Introduction

Wastewater from a cattle slaughterhouse is a mixture of the processing water from both the slaughtering line and the cleaning of the guts, which causes a large variation in the concentration of organic matter. The main pollutant in slaughterhouse effluents is organic matter. The contributors of organic load to these effluents are paunch, feces, fat and lard, grease, undigested food, blood, suspended material, urine, loose meat, soluble proteins, excrement, manure, grit and colloidal particles [1], [2].

Untreated slaughterhouses waste entering into a municipal sewage purification system may create severe problems, due to the very high biological oxygen demand (BOD) and chemical oxygen demand (COD) [3]. Therefore treating of slaughterhouse wastewater is very important for prevention of high organic loading to municipal wastewater treatment plants. The most common methods used for treating slaughterhouse wastewaters are fine screening, sedimentation, coagulation– flocculation, trickling filters and activated sludge processes.

The treatment of slaughterhouse wastewater by various methods such as aerobic and anaerobic biological systems [4], [5], [6], [7] and hybrid systems [2] have been intensively studied. Aerobic treatment processes are limited by their high energy consumption needed for aeration and high sludge production. Also, the anaerobic treatment of slaughterhouse wastewater is often slowed or impaired due to the accumulation of suspended solids and floating fats in the reactor which lead to a reduction in the methanogenic activity and biomass wash-out. In addition, it is also reported that anaerobic treatment is sensitive to high organic loading rates, as a serious disadvantage [8]. Even though biological processes are effective and economical, both biological processes require long hydraulic retention time and large reactor volumes, high biomass concentration and controlling of sludge loss, to avoid the wash-out of the sludge. Among physico-chemical processes, dissolved air flotation (DAF) and coagulation–flocculation units are widely used for the removal of total suspended solids (TSS), colloids, and fats from slaughterhouse wastewaters [1].

Chemical coagulation of slaughterhouse wastewater has also been studied by adding aluminum salts and polymer compounds, and a maximum COD removal efficiency of 45–75% has been reported [9], [10]. Polyaluminum chloride (PACl) is commonly used as the flocculant to coagulate small particles into larger flocs that can be efficiently removed in the subsequent separation process of sedimentation and/or filtration. Much attention has been paid to PACl in recent years because of its higher efficiency and relatively low costs compared with the traditional flocculants [11], [12]. On the other hand, PACl has become one of the most effective coagulant agents in water and wastewater treatment facilities with various applications, including removal of colloids and suspended particles, organic matter, metal ions, phosphates, toxic metals and color [13].

Recently, electrochemical methods such as electrooxidation [14] and electrocoagulation have been widely used as an attractive and suitable method for the treatment of various kinds of wastewater such as poultry and cattle slaughterhouse wastewater and wastewaters contain heavy metals, by virtue of various benefits including environmental compatibility, adaptability, energy efficiency, safety, selectivity, amenability to automation, and cost effectiveness [15], [16], [17], [18], [19], [20]. An examination of the chemical reactions occurring in the electrocoagulation process shows that the main reactions occurring at the electrodes (aluminum electrodes) are:(1)(2)

In addition, Al3+ and OH ions generated at electrode surfaces react in the bulk wastewater to form aluminum hydroxide:(3)

The aluminum hydroxide flocs normally have large surface areas which are beneficial for a rapid adsorption of soluble organic compounds and trapping of colloidal particles [15], [16], [21]. Also, these flocs polymerize further and are removed easily from aqueous medium by sedimentation or/and flotation by hydrogen gas.

Chemical coagulation using PACl and electrocoagulation process with aluminum electrodes of wastewater from a cattle slaughterhouse is described in this article. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process separately to achieve the required legal direct-discharge limit of COD and BOD5 which is 60 and 30 mg/L in Iran for the slaughterhouse industry effluents. The influence of the operating variables such as coagulant dose, pH, applied voltage and reaction time on the removal efficiencies of major pollutants was also determined. Information regarding the electrical energy consumption (EEC) is also included to provide an estimation of the cost of pollutants removal by an electrocoagulation system.

Results and Discussion

Wastewater characterization

Table 1 presents the slaughterhouse wastewater characteristics prior to any treatment, after 24 h settling time and the guidelines from Iran for effluent discharge in the sewage urban works. The values of the pollution parameters were lowered after 24 h of preliminary settling time. Also, the comparison of these values showed that, the COD, BOD5, microbial indicators (Total and Fecal Coliforms) and the concentration of Oil and grease were very greater than those recommended by Iran. Consequently, the slaughterhouse effluent needed to be treated before discharge.

thumbnail
Table 1. Characteristics of the experimental cattle slaughterhouse wastewater.

https://doi.org/10.1371/journal.pone.0040108.t001

Effect of preliminary settling time

Preliminary settling process is a natural treatment method that requires no chemical addition. Although some workers realized the importance of the natural settling process, there is little information available in the literature on the effect of the preliminary settling time on TSS removal capacity [22]. Most studies carried out on the treatment of slaughterhouse wastewater were based on diluted pre-settled wastewater [23].

In this study, the raw slaughterhouse wastewater was allowed to settle for 24 h in a preliminary settling tank before the addition of a coagulant. The process had an effect on BOD5, COD, TSS, TKN and coliform bacteria removals on the first 24 h. TKN concentration reduced from 137±12 to 92±12 mg/L (on average 33% TKN removal efficiency), COD concentration reduced from 5817±473 to 4159±281 mg/L (approximately 28% COD removal efficiency) whereas BOD5 was reduced in the wastewater from 2543±362 to 2204±177 mg/L (about 13% BOD5 removal efficiency). Furthermore, TSS concentration was reduced to 1172±84 mg/L (approximately 64% TSS removal efficiency). Similar results were reported by Amuda and Alade [10].

Also, data revealed that the effluent of the settling unit is characterized by high load of organic matter. The ratio BOD5/COD of approximately 0.5, indicates that 50% of the COD of this wastewater is easily able to be degraded by biological treatment. Nevertheless, the remainder COD is high, which indicates the necessity of an efficient physicochemical treatment for this wastewater.

Effect of coagulation process (first step)

Coagulation/flocculation experiments using PACl as coagulant in the jar test were performed to investigate the effect of coagulation process in the removal efficiencies of COD, BOD5, TSS, TKN and coliform bacteria. Therefore, PACl was added to the slaughterhouse wastewater to achieve particle instability and increase in the particle size, consequently achieving effective removal of organic substances present as COD and BOD5. The doses of PACl as coagulant were varied between 0 and 100 mg/L to determine the optimum dose of PACl for pollutants removal. The results of jar-tests using the PACl individually are presented in Table 2 and Figure 1. It is shown that at lower doses of the PACl (25 mg/L), COD, BOD5, TSS and TKN removal efficiency reached a maximum of 37%, 31%, 47% and 27%, respectively. Aguilar et al. [24] reported TKN removal efficiency 50–60% by using PACl as coagulant from slaughterhouse wastewater. Also, Amuda and Alade [10] were reported maximum removal efficiency 65% and 34% of COD and TSS using a 750 mg/L dose of alum as coagulant in abattoir wastewater treatment.

thumbnail
Figure 1. Effects of coagulant dose (PACl) on pollutants removal efficiency at pilot scale coagulation process.

https://doi.org/10.1371/journal.pone.0040108.g001

thumbnail
Table 2. Influence of PACl dosage on water quality parameters of coagulated mixed liquor (mean values).

https://doi.org/10.1371/journal.pone.0040108.t002

As it shown in Figure 1, the efficiency of the process increased with increasing dosages of coagulant (PACl). The curve obtained with PACl points to a considerable increase in performance from the lowest dose up to 100 mg/L. On the other hand in chemical coagulation, as seen in Figure 1, an increase in COD, BOD5, TSS, TKN and other pollutants removal efficiency is noted with increasing PACl dosage, reaching nearly 40–60% for PACl dosage of 100 mg/L. Al-Mutairi et al. [9] reported that suspended solids and turbidity removal from slaughterhouse wastewater increased substantially as the alum (as coagulant) dosage is increased. Also, Figure 1 shows that the TSS removal and COD and BOD5 reduction trends are similar to each other. This may be due to the high organic contents of the suspended solid particles.

Maximum TC and FC removal efficiency of >99.9% (Table 2) were obtained by using PACl at the dosage of 100 mg/L. The TC and FC reduction, increase with increase in coagulant dosage.

TC indicator of effluent with coagulant dose 25 mg/L PACl was reduced from 2.3×109 to 2.8×107 (MPN/100mL) (approximately more than 98% TC removal efficiency), and by increasing the coagulant dose to 100 mg/L, the TC indicator of effluent was decreased was reduced from 1.7×108 to 1.6×106 (MPN/100mL) (on average more than 99% TC removal efficiency) that is much more than permissible level. A similar reduction trend was determined for FC indicator. Similar results were obtained in previous reports concerning the electrocoagulation of wastewater from vegetable oil refinery wastewater using aluminum electrodes (with adding PACl as coagulant aid) [19].

According the results of this study (Table 2) it can be concluded that although the efficiency for removal of most parameters from slaughterhouse wastewater are high, but the concentration of pollutants in effluent of chemical coagulation process does not meet the effluent discharge standards to the environment. Thus, the effluent from conventional coagulation should be preceded by another treatment process to be completed. For this purpose, in this research, electrocoagulation was employed as a completion of treatment process to obtain discharge standards.

Effect of electrocoagulation process (second step)

Electrocoagulation processes a direct current source between metal electrodes immersed in wastewater. The electrical current causes the dissolution of metal electrodes commonly iron and aluminum into wastewater. The dissolved metal ions, at an appropriate pH, can form wide ranges of coagulated species and metal hydroxides that destabilize and aggregate the suspended particles or precipitate and adsorb dissolved contaminants [25], [26].

As be mentioned earlier, an examination of the chemical reactions occurring in the electrocoagulation process shows that the main reactions occurring at the aluminum electrodes are:(4)(5)(6)

monomeric species such as Al(OH)2+, Al(OH)2+, Al2(OH)24+, Al(OH)4− and polymeric species such as Al6(OH)153+, Al7(OH)174+, Al8(OH)204+, Al13O4(OH)247+, Al13(OH)345+ are formed during the electrocoagulation process [26], [27]. The aluminum hydroxide flocs act as adsorbents and/or traps for pollutants and so eliminate them from the solution [28], [29].

As mentioned earlier, the performances by the two pretreatment, namely, preliminary settling and chemical coagulation, were not carried out efficiently enough to satisfy the national guideline of effluent qualities. Additional dosage of coagulant (PACl) and longer time were needed to keep the national guideline of the effluent qualities. Therefore, the electrocoagulation process was employed as the final treatment step in this study. In adopting the electrocoagulation process, it was intended to treat the pollutant efficiently as well as economically.

The effects of applied voltage and reaction time on electrocoagulation process of slaughterhouse wastewater treatment were determined. The results of the effects of operating parameters on pilot scale electrocoagulation process are shown in Table 3 and Figures 2, 3, 4, and 5.

thumbnail
Figure 2. Effect of applied voltage on pollutants removal efficiency (coagulant dose: 25 mg/L, reaction time: 60 min).

https://doi.org/10.1371/journal.pone.0040108.g002

thumbnail
Figure 3. Effect of applied voltage on pollutants removal efficiency (coagulant dose: 50 mg/L, reaction time: 60 min).

https://doi.org/10.1371/journal.pone.0040108.g003

thumbnail
Figure 4. Effect of applied voltage on pollutants removal efficiency (coagulant dose: 75 mg/L, reaction time: 60 min).

https://doi.org/10.1371/journal.pone.0040108.g004

thumbnail
Figure 5. Effect of applied voltage on pollutants removal efficiency (coagulant dose: 100 mg/L, reaction time: 60 min).

https://doi.org/10.1371/journal.pone.0040108.g005

thumbnail
Table 3. Influence of electrocoagulation process using aluminum electrodes on effluent quality parameters (mean values).

https://doi.org/10.1371/journal.pone.0040108.t003

Effect of applied voltage

One of the most important parameter influencing the performance and economy of the electrocoagulation process is the applied voltage at the electrodes [30]. To understand the effect of applied voltage on the efficiency of electrocoagulation process in treating of slaughterhouse wastewater, several voltages in the range of 10 to 40 V were applied between the electrodes in the electrocoagulation cell, and pollutants removal was determined at the conditions given in Table 3.

The applied voltage is expected to exhibit a strong effect on electrocoagulation, especially on the COD abatement: higher the current (voltage), shorter the treatment. The supply of current to the electrocoagulation system determines the amount of Al3+ ion released from the respective electrodes and the amount of resulting coagulant. Thus, more Al3+ ion get dissolved into the solution and the formation rate of Al(OH)3 is increased. Also, it is well-known that electrical potential not only determines the coagulant dosage rate but also the bubble production rate and size and the flocs growth [31], [32], which can influence the treatment efficiency of the electrocoagulation process.

As it can be seen from Table 3 and Figures 2, 3, 4, and 5, the removal efficiency of pollutants is very high and as expected, it appears that for a given time, the removal efficiency increased significantly with increase of electrical potential. As the results shown in Table 3 and Figures 2, 3, 4, and 5, the removal efficiencies increased as the electrical potentials are increased. As an example, COD concentration of chemical coagulation process with 25 mg/L PACl has decreased from 2643 to 555 mg/L (approximately 79% COD removal efficiency) after electrocoagulation process with electrical potential of 10 V. Again, by increasing electrical potential to 40 V, the COD concentration in the effluent decreased to 108 mg/L in 60 min (approximately 96% COD removal efficiency). In addition, the COD of effluent from chemical coagulation with 100 mg/L PACl, was decreased to about 294 mg/L (approximately 83% COD removal efficiency) by electrocoagulation process with electrical potential of 10 V, and by increasing the electrical potential to 40 V, the COD of effluent was decreased to less than 13 mg/L (on average more than 99% COD removal efficiency) that is lower than permissible level.

According to the results of Table 3, and Figures 2, 3, 4, and 5, TKN of chemical coagulation process with 25 mg/L PACl was reduced to lower than 50 mg/L after electrocoagulation process with electrical potential of 10 V (approximately 65% TKN removal efficiency), and by increasing electrical potential to 40 V, the TKN concentration in the effluent decreased to 26 mg/L (about 81% TKN removal efficiency). Furthermore, with increase in coagulant dose to 100 mg/L and increase of applied voltage to 40 V, TKN concentration in effluent was reduced to lower than 7 mg/L (on average 94% TKN removal efficiency). A similar trend was seen for TSS and BOD5 parameters.

Also, as can be seen from Table 3, the removal efficiency of bacterial indicators (TC and FC) is very high and efficiency was increased with increase in applied voltage from 10 to 40 V. Maximum removal efficiency (>99.9%) was obtained in applied voltage 40 V (coagulant dosage 100 mg/L), and thus the effluent quality was reached to permissive levels (lower than 1000 and 400 for TC and FC, respectively) and hence discharge of this effluent to environment is safe. Also, minimum removal efficiency occurred in the lowest electrical potential (10 V). This is ascribed to the fact that at high voltage, the amount of aluminum oxidized increased, resulting in a greater amount of precipitate for the removal of pollutants. In addition, it was demonstrated that bubbles density increases and their size decreases with increasing current density [33], resulting in a greater upwards flux and a faster removal of pollutants and sludge flotation. As be mentioned earlier, the main mechanisms for removal of pollutants in this process are rapid adsorption of soluble organic compounds and trapping of colloidal particles in “sweep flocs” (Al(OH)3). Nevertheless, Bayar et al. [34] was reported that increase in the current density does not cause an expected removal efficiency increase; on the contrary, it can cause a relatively negative effect on it. Also, a similar trend was seen in the study of Holt et al. [32].

Electrical energy and electrode consumption

Electrical energy consumption is a very important economical parameter in the electrocoagulation process. Therefore, for the same operating conditions, after 60 min of electrocoagulation, consumption of energy and aluminum electrode is also represented in Figures 6 and 7. The electrical energy consumption was calculated using the related equations [35].

thumbnail
Figure 6. Electrical energy consumption during coagulation-electrocoagulation process (kWh/L).

https://doi.org/10.1371/journal.pone.0040108.g006

thumbnail
Figure 7. Electrode consumption during chemical coagulation-electrocoagulation process.

https://doi.org/10.1371/journal.pone.0040108.g007

It can be understood from Figures 6 and 7 that electrical energy and electrode consumption were found to increase with increasing the applied voltage as would be expected in any other electrolytic process. An increase in applied voltage from 10 to 40 V causes an increase in energy consumption from about 0.001 to 0.08 kWh/L and from 0.011 to approximately 0.09 kWh/L for 25 and 100 mg/L of coagulant dosage (PACl), respectively. A similar trend was seen in the study of Bayar et al. [34] on Poultry slaughterhouse wastewater treatment by electrocoagulation method.

Also, as shown in Figure 7, an increase in applied voltage from 10 to 40 V causes an increase in electrode consumption from about 0.41 to 1.23 g/L and 0.51 to 1.3 g/L of pollutants for 25 and 100 mg/L of PACl, respectively. This result is in agreement with the results obtained by Bazrafshan et al. [36], [37], [38].

When the applied voltage was increased from 10 V to 40 V, the COD and BOD5 removal efficiency increased appreciably, to more than approximately 99%, whereas the corresponding specific energy consumption increased only slightly. Therefore, in present study, 40 V is chosen as optimum operating voltage for electrocoagulation process.

Conclusions

In this study, chemical coagulation using Polyaluminum chloride (PACl) and Electrocoagulation process using aluminum electrodes of wastewater from a cattle slaughterhouse was investigated. The effects of the different operational parameters on the removal of pollutants analyzed. The following conclusions can be reached from the results obtained in this work:

  1. - The installation of a good fat separator prior to each biological or chemical treatment unit seemed an appropriate alternative to a chemical coagulation and electrocoagulation process.
  2. - Preliminary settling time were investigated and found to be important operational parameter for effective treatment of slaughterhouse wastewater.
  3. - A preliminary settling time of 24 h had an effect on the BOD5, COD, TSS and TKN with removal efficiency up to 14%, 29%, 64% and 33%, respectively.
  4. - According to the results obtained from the present experiments, the removal efficiencies increased by increasing the coagulant dose and electrical potential. At the highest applied voltage, the fastest treatment rate for pollutants (COD, BOD5, TSS, TKN and microbial parameters) removal was obtained. Moreover, the energy consumption increased by increasing the applied electrical potential.
  5. - Evaluation of the experimental results indicates that both processes (chemical coagulation and Electrocoagulation) show excellent efficiency at reducing of pollutants.
  6. - Based on this study results, although the coagulation process had high efficiency in removing organic and microbial contaminants, but nevertheless it’s not able to meet discharge standards, hence a supplemental process (such as electrocoagulation process) is essential for enhance effluent quality.
  7. - Finally according to the results of this study, it can be concluded that the combined application of chemical coagulation and electrocoagulation processes is able to meet effluent standards for safe discharge to environment.

Materials and Methods

Slaughterhouse effluent

The effluent used throughout this study was taken from a local cattle Slaughterhouse plant with 250 cows per day capacity, located in Zahedan City in the province of Sistan and Baluchestan province (Iran), producing approximately 60 m3 of wastewater daily. The cattle slaughterhouse effluent was sampled after the screening of coarser solids using a filter having a pore size of approximately 2.0 mm and sedimentation for 24 h. Samples were collected in polypropylene bottles, shipped cold, and kept at 4°C before use. The length of the storage before starting experiments varied from one day to six weeks. The effluent has been sampled at different times during this study and the initial characteristics varied with time (Table 1). This effluent initially contained high concentrations of soluble and undissolved organics (4159±81 mg/L COD, 2204±77 mg/L BOD5).

Chemical treatment (coagulation) of slaughterhouse effluent

All the chemicals used in the study were of analytical reagent (AR) grade. Poly- aluminum chloride (PACl) Al12Cl12(OH)24 was chosen for this study because it has been used extensively at water and wastewater treatment plants to remove solids and may function as an effective and less expensive coagulant. PACl was used in this study up to 100 mg/L (25, 50, 75 and 100 mg/L). A six-beaker jar test (flocculator) was set up at room temperature for each trial. Each of the beakers contained 2 L of settled wastewater. The coagulants were added into the beakers, and the pH values were immediately adjusted to the preset values (7±0.1) using NaOH or H2SO4 for pH-controlled experiments. Rapid stirring at 150 rpm for 2 min was followed by gentle mixing at 50 rpm for 20 min, and the solids formed were left to settle for 30 min. Samples were taken from the water surface (supernatant) and filtered through 0.45-mm membranes. After chemical coagulation, electrocoagulation process with aluminum electrodes was performed on the supernatant.

Electrochemical treatment of slaughterhouse effluent

In each run, wastewater (supernatant) after chemical coagulation (first stage of treatment) was poured into the electrocoagulation cell. All experiments were performed in a bipolar batch reactor (Figure 8), with four aluminum electrode connected in parallel. Only the outer electrodes were connected to the power source, and anodic and cathodic reactions occurred on each surface of the inner electrode when the current passed through the electrodes. The internal size of the cell was 15 Cm×15 Cm×25 Cm (width × length × depth) with an effective volume of 2000 Cm3. The volume (V) of the solution of each batch was 2 L. The active area of each electrode (plate) was 14×20 Cm with a total area of 280 Cm2. The distance between electrodes was 1.5 Cm. A power supply having an input of 220 V and variable output of 0–40 V (10, 20, 30 and 40 V) with maximum current of 5 ampere was used as direct current source. The temperature of each system was maintained at 25±1°C. Different samples of 100 ml were taken at 15 min intervals for up to 1 h and filtered before being analysed to determine BOD5, COD, TSS and other parameters. During the runs, the reactor unit was stirred at 150 rpm by a magnetic stirrer to allow the chemical precipitate to grow large enough for removal. During electrocoagulation, an oxide film formed at the anode. In order to overcome electrode passivation at the anode, the electrodes were rinsed in diluted HCl solution (5% v/v) after each experiment and rinsed again with tap water and finally weighted. Also the electrodes reweighted to calculate sacrificial electrode consumptions. These weights are used in the calculations of the total operating cost. In addition, the electrical energy consumed per unit volume of treated wastewater has been calculated for different experimental conditions. All analyses were conducted in duplicate for reproducibility of the experimental results, and all of the data in the Figures and Tables were the average ones.

thumbnail
Figure 8. The schematic view of coagulation and electrocoagulation reactor.

https://doi.org/10.1371/journal.pone.0040108.g008

Analytical

COD, BOD5, oil-grease, conductivity, pH, total solids (TS), total suspended solids (TSS), and total Kjeldhal nitrogen (TKN) determinations were determined according to the standard methods [39]. COD was measured using COD reactor and direct reading spectrophotometer (DR/5000, HACH, USA). Five-day biological oxygen demand (BOD5) was determined by the manometric method with a respirometer (BSB-Controller Model 620 T (WTW)). Oil-grease was determined with hexane extraction. The pH and conductivity were adjusted to a desirable value using NaOH or H2SO4, and NaCl, and measured using a pH meter model E520 (Metrohm Herisau, Switzerland) and a Conductivity Meter (Jenway Model 4200), respectively. Also the most-probable-number technique was used for the enumeration of total coliform (TC) and fecal coliform (FC) bacteria [39].

Acknowledgments

E. Bazrafshan gratefully acknowledges helpful comment from Dr. M.A. Zazouli.

Author Contributions

Conceived and designed the experiments: EB AHM. Performed the experiments: EB KAO. Analyzed the data: MF. Contributed reagents/materials/analysis tools: FKM. Wrote the paper: EB AHM.

References

  1. 1. Asselin M, Drogui P, Benmoussa H, Blais JF (2008) Effectiveness of electrocoagulation process in removing organic compounds from slaughterhouse wastewater using monopolar and bipolar electrolytic cells. Chemosphere 72: 1727–1733.
  2. 2. Tezcan Un U, Koparal AS, Bakir Ogutveren U (2009) Hybrid processes for the treatment of cattle-slaughterhouse wastewater using aluminum and iron electrodes. J Hazard Mater 164: 580–586.
  3. 3. Alvarez R, Liden G (2008) Semi-continuous co-digestion of solid slaughterhouse waste, manure, and fruit and vegetable waste. Renew Energ 33: 726–734.
  4. 4. Masse L, Masse DI (2005) Effect of soluble organic, particulate organic and hydraulic shock loads on anaerobic sequencing batch reactors treating slaughterhouse wastewater at 20C. Process Biochem 40: 1225–1232.
  5. 5. Torkian A, Eqbali A, Hashemian SJ (2003) The effect of organic loading rate on the performance of UASB reactor treating slaughterhouse effluent. Resour Conserv Recy 40: 1–11.
  6. 6. Manjunath NT, Mehrotra I, Mathur RP (2000) Treatment of wastewater from slaughterhouse by DAF-UASB system. Water Res 34: 1930–1936.
  7. 7. Palatsi J, Vinas M, Guivernau M, Fernandez B, Flotats X (2011) Anaerobic digestion of slaughterhouse waste: Main process limitations and microbial community interactions. Bioresource Technol 102: 2219–2227.
  8. 8. Cuetos MJ, Gomez X, Otero M, Moran A (2008) Anaerobic digestion of solid slaughterhouse waste (SHW) at laboratory scale: Influence of co-digestion with the organic fraction of municipal solid waste (OFMSW). Biochem Eng J 40: 99–106.
  9. 9. Al-Mutairi NZ, Hamoda MF, Al-Ghusain I (2004) Coagulant selection and sludge conditioning in a slaughterhouse wastewater treatment plant. Bioresource Technol 95: 115–119.
  10. 10. Amuda OS, Alade A (2006) Coagulation/flocculation process in the treatment of abattoir wastewater. Desalination 196: 22–31.
  11. 11. Hua Ch, Liu H, Qua J (2005) Preparation and characterization of polyaluminum chloride containing high content of Al13 and active chlorine, Colloid Surface A 260: 109–117.
  12. 12. Yan M, Wang D, Yu J, Ni J, Edwards M, et al. (2008) Enhanced coagulation with polyaluminum chlorides: Role of pH/Alkalinity and speciation. Chemosphere 71: 1665–1673.
  13. 13. Zouboulis AI, Tzoupanos N (2010) Alternative cost-effective preparation method of polyaluminium chloride (PACL) coagulant agent: Characterization and comparative application for water/wastewater treatment. Desalination 250: 339–344.
  14. 14. Tezcan Un U, Altay U, Koparal AS, Bakır Ogutveren U (2008) Complete treatment of olive mill wastewaters by electrooxidation. Chem Eng J 39: 445–452.
  15. 15. Bayramoglu M, Kobya M, Eyvaz M, Senturk E (2006) Technical and economic analysis of electrocoagulation for the treatment of poultry slaughterhouse wastewater. Sep Purif Technol 51: 404–408.
  16. 16. Bazrafshan E, Mahvi AH, Zazouli MA (2011) Removal of zinc and copper from aqueous Solutions by electrocoagulation technology using iron electrodes. Asian J Chem 23: 5506–5510.
  17. 17. Bazrafshan E, Mahvi AH, Naseri S, Mesdaghinia AR (2008) Performance evaluation of electrocoagulation process for removal of chromium (VI) from synthetic chromium solutions using iron and aluminum electrodes. Turkish J Eng Environ Sci 32: 59–66.
  18. 18. Bazrafshan E, Mahvi AH, Naseri S, Shaighi M (2007) Performance evaluation of electrocoagulation process for Diazinon removal from aqueous environment by using iron electrodes. Iran J Environ Health Sci Eng 4: 127–132.
  19. 19. Tezcan Un U, Koparal AS, Bakir Ogutveren U (2009) Electrocoagulation of vegetable oil refinery wastewater using aluminum electrodes. J Environ Manage 90: 428–433.
  20. 20. Nouri J, Mahvi AH, Bazrafshan E (2010) Application of electrocoagulation process in removal of zinc and copper from aqueous solutions by aluminum electrodes. Int J Environ Res 4: 201–208.
  21. 21. Adhoum N, Monser L, Bellakhal N, Belgaied JE (2004) Treatment of electroplating wastewater containing Cu2+, Zn2+ and Cr (VI) by electrocoagulation. J Hazard Mater B112: 207–213.
  22. 22. Ra CS, Lo KV, Mavinic DS (1997) Swine wastewater treatment by a batch-mode 4-stage process: loading rate control using Orp. Environ Technol 18: 615–621.
  23. 23. Al-Mutairi NZ, Hamoda MF, Al-Ghusain IA (2003) Performance-based characterization of contact stabilization process for slaughterhouse wastewater. J Environ Sci Healt A 38: 2287–2300.
  24. 24. Aguilar MI, Saez J, Llorens M, Soler A, Ortuno JF (2002) Nutrient removal and sludge production in the coagulation-flocculation process. Water Res 36: 2910–2919.
  25. 25. Chen GH (2004) Electrochemical technologies in wastewater treatment. Sep Purif Technol 38: 11–41.
  26. 26. Canizares P, Carmona M, Lobato J, Martinez F, Rodrigo MA (2005) Electrodissolution of aluminum electrodes in electrocoagulation processes. Ind Eng Chem Res 44: 4178–4185.
  27. 27. Can OT, Bayramoglu M, Kobya M (2003) Decolorization of reactive dye solutions by electrocoagulation using aluminum electrodes. Ind Eng Chem Res 42: 3391–3396.
  28. 28. Cenkin VE, Belevstev AN (1985) Electrochemical treatment of industrial wastewater. Eff Water Treat J 25: 243–249.
  29. 29. Ogutveren UB, Gonen N, Koparal AS (1994) Removal of chromium from aqueous solutions and plating bath rinse by an electrochemical method. Int J Environ Stud 45: 81–87.
  30. 30. Mollah M, Schennach R, Parga JR, Cocke DL (2001) Electrocoagulation. (EC)-science and applications. J Hazard Mater B84: 29–41.
  31. 31. Letterman RD, Amirtharajah A, O. Melia CR (1999) A Handbook of Community Water Supplies. AWWA, Mc Graw-Hill, N. Y. USA.
  32. 32. Holt PH, Barton GW, Wark M, Mitchell AA (2002) A quantitative comparison between chemical dosing and electrocoagulation. Colloid Surface A 211: 233–248.
  33. 33. Khosla NK, Venkachalam S, Sonrasundaram P (1991) Pulsed electrogeneration of bubbles for electroflotation. J Appl Electrochem 21: 986–990.
  34. 34. Bayar S, Sevki YY, Yilmaz AE, Irdemez S (2011) The effect of stirring speed and current density on removal efficiency of poultry slaughterhouse wastewater by electrocoagulation method. Desalination 280: 103–107.
  35. 35. Martınez-Huitle CA, Brillas E (2009) Decontamination of wastewaters containing synthetic organic dyes by electrochemical methods: a general review. App Catal B Environ 87: 105–145.
  36. 36. Bazrafshan E, Biglari H, Mahvi AH (2012) Phenol removal by electrocoagulation process from aqueous solutions. Fresen Environ Bull 21: 364–371.
  37. 37. Bazrafshan E, Biglari H, Mahvi AH (2012) Application of electrocoagulation process using Iron and Aluminum electrodes for fluoride removal from aqueous environment. E-J Chem 9: 2297–2308.
  38. 38. Bazrafshan E, Biglari H, Mahvi AH (2012) Humic acid removal from aqueous environments by electrocoagulation process using iron electrodes. E-J Chem 9: 2453–2461.
  39. 39. APHA AWWA WEF (1995) Washington DC, USA. Standard Methods for the Examination of Water and Wastewater, 19th Ed.