Sensitivity and specificity of an electronic nose in diagnosing pulmonary tuberculosis among patients with suspected tuberculosis

  • Antonia M. I. Saktiawati,

    Roles Conceptualization, Formal analysis, Funding acquisition, Investigation, Methodology, Project administration, Visualization, Writing – original draft, Writing – review & editing

    Affiliations Department of Internal Medicine, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Yogyakarta, Indonesia, University of Groningen, University Medical Center Groningen, Department of Pulmonary Diseases and Tuberculosis, Groningen, the Netherlands, Center for Tropical Medicine, Universitas Gadjah Mada, Yogyakarta, Indonesia

  • Ymkje Stienstra,

    Roles Conceptualization, Formal analysis, Methodology, Visualization, Writing – review & editing

    Affiliation University of Groningen, University Medical Center Groningen, Department of Internal Medicine—Infectious Diseases, Groningen, the Netherlands

  • Yanri W. Subronto,

    Roles Funding acquisition, Methodology, Supervision, Validation, Writing – review & editing

    Affiliations Department of Internal Medicine, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Yogyakarta, Indonesia, Center for Tropical Medicine, Universitas Gadjah Mada, Yogyakarta, Indonesia

  • Ning Rintiswati,

    Roles Funding acquisition, Resources, Validation, Writing – review & editing

    Affiliations Center for Tropical Medicine, Universitas Gadjah Mada, Yogyakarta, Indonesia, Department of Microbiology, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Yogyakarta, Indonesia

  • Sumardi,

    Roles Investigation, Methodology, Resources, Writing – review & editing

    Affiliation Department of Internal Medicine, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Yogyakarta, Indonesia

  • Jan-Willem Gerritsen,

    Roles Data curation, Funding acquisition, Methodology, Resources, Software, Validation, Writing – review & editing

    Affiliation eNose B.V. (The eNose Company), Zutphen, The Netherlands

  • Henny Oord,

    Roles Data curation, Formal analysis, Funding acquisition, Resources, Software, Validation, Writing – review & editing

    Affiliation eNose B.V. (The eNose Company), Zutphen, The Netherlands

  • Onno W. Akkerman,

    Roles Conceptualization, Methodology, Resources, Supervision, Writing – review & editing

    Affiliations University of Groningen, University Medical Center Groningen, Department of Pulmonary Diseases and Tuberculosis, Groningen, the Netherlands, University of Groningen, University Medical Center Groningen, Tuberculosis Center Beatrixoord, Haren, the Netherlands

  • Tjip S. van der Werf

    Roles Conceptualization, Methodology, Supervision, Validation, Writing – review & editing

    t.s.van.der.werf@umcg.nl

    Affiliations University of Groningen, University Medical Center Groningen, Department of Pulmonary Diseases and Tuberculosis, Groningen, the Netherlands, University of Groningen, University Medical Center Groningen, Department of Internal Medicine—Infectious Diseases, Groningen, the Netherlands

Abstract

Objective

To investigate the potency of a hand-held point-of-care electronic-nose to diagnose pulmonary tuberculosis (PTB) among those suspected of PTB.

Methods

Setting: Lung clinics and Dr. Sardjito Hospital, Yogyakarta, Indonesia. Participants: patients with suspected PTB and healthy controls. Sampling: 5 minutes exhaled breath. Sputum-smear-microscopy, culture, chest-radiography, and follow-up for 1.5–2.5 years, were used to classify patients with suspected PTB as active PTB, probably active PTB, probably no PTB, and no PTB. After building a breath model based on active PTB, no PTB, and healthy controls (Calibration phase), we validated the model in all patients with suspected PTB (Validation phase). In each variable (sex, age, Body Mass Index, co-morbidities, smoking status, consumption of alcohol, use of antibiotics, flu symptoms, stress, food and drink intake), one stratum’s Receiver Operating Characteristic (ROC)-curve indicating sensitivity and specificity of the breath test was compared with another stratum’s ROC-curve. Differences between Area-under-the-Curve between strata (p<0.05) indicated an association between the variable and sensitivity—specificity of the breath test. Statistical analysis was performed using STATA/SE 15.

Results

Of 400 enrolled participants, 73 were excluded due to extra-pulmonary TB, incomplete data, previous TB, and cancer. Calibration phase involved 182 subjects, and the result was validated in 287 subjects. Sensitivity was 85% (95%CI: 75–92%) and 78% (95%CI: 70–85%), specificity was 55% (95%CI: 44–65%) and 42% (95%CI: 34–50%), in calibration and validation phases, respectively. Test sensitivity and specificity were lower in men.

Conclusion

The electronic-nose showed modest sensitivity and low specificity among patients with suspected PTB. To improve the sensitivity, a larger calibration group needs to be involved. With its portable form, it could be used for TB screening in remote rural areas and health care settings.

Introduction

On 26 September, 2018, the United Nations (UN) had a high-level meeting in the UN headquarters in New York on tuberculosis (TB). The discussion focused on accelerating actions to end TB by 2030 [1]. In 2017, the death toll was still huge–with 1.3 Million death, and an additional 300 000 among HIV-coinfected, TB leads the causes of death by an infectious disease; in 2017 alone, 10 Million people fell ill with TB [1]. Clearly, new diagnostic tools are needed to identify individuals in the community–and in health care facilities–that continue to spread this airborne disease. In many TB high-burden countries, pulmonary tuberculosis (PTB) is commonly diagnosed by sputum smear microscopic examination [1]. Sputum microscopy is labor-intensive, and the technique does not differentiate Mycobacterium tuberculosis (MTB) from non-tuberculosis mycobacteria [2]. Though sputum culture is considered gold standard, it is problematic in low-resource settings, because it is expensive, time-consuming, and vulnerable to technical failure [3]. Nucleic acid amplification techniques such as Xpert MTB/ RIF allows for fast identification of MTB [4], but costs remain challenging; it still requires sputum sampling and is neither portable nor fit for point-of-care in remote rural areas with unstable electricity supply. For all of the above-mentioned sputum-based tests, appropriate sputum specimens are required. Meanwhile, not all patients with suspected TB were able to collect an adequate and good quality sputum sample. Chest radiography (CXR), a non-sputum-based test that is usually used, lacks specificity [3].

There is an increasing evidence that analysis of exhaled breath using electronic nose (e-nose) could be used as a novel diagnostic technique [59]. An e-nose is a machine that can detect and differentiate odours from any biological materials, such as breath, urine, or faeces, with a sensor array. This array consists of non-specific sensors. An odour stimulates the sensor array to produce a specific fingerprint. Patterns or fingerprints from known odours are used to build a model and train a pattern recognition system, thus unknown odours can be classified based on this model [10]. E-nose has been used for diagnosis of various diseases, i.e. asthma [5], Chronic Obstructive Pulmonary Disease (COPD) [5,6], urinary tract infection [7], lung cancer [8], and brain cancer [9]. A prototype of an e-nose to diagnose PTB was used by Bruins et al. in Bangladesh [11]. They found sensitivity of 93.5% and a specificity of 85.3% to differentiate PTB patients from healthy controls, and a sensitivity of 76.5% and specificity of 87.2% when differentiating PTB patients from other subjects (non-PTB patients and healthy subjects) [11]. However, this e-nose prototype used separate bags to collect exhaled breath that might introduce errors due to interaction between the Volatile Organic Compounds (VOCs) with the bags materials [12]. A newer device that is portable, use rechargeable battery, and does not use separate bags (Aeonose) was tested in Paraguay, and showed high sensitivity (88%) and specificity (92%) to differentiate PTB patients from asthma/COPD and healthy subjects [12].

No previous studies have investigated the potential of the e-nose (Aeonose) device to diagnose PTB among patients presenting with signs and symptoms suggesting PTB, while this would typically provide the added value of such test. We therefore investigated the diagnostic potential of Aeonose to identify PTB among patients with suspected PTB. Our secondary objective was to investigate factors that associated with the sensitivity and specificity of the breath test. The study was conducted in Indonesia, a lower-middle-income country with a population of 264 million, being the third highest TB-burdened country in the world [1]. Many patients live in remote rural areas with difficult access to health care facilities and human resources [13]—a setting, where an accurate and easy-to-handle e-nose would be a tremendous asset.

Materials and methods

Study design

In this diagnostic cross-sectional study, we enrolled a cohort of patients with suspected TB and healthy controls. We conducted breath tests, and followed study participants over time to confirm correct diagnosis. Patients with suspected TB were recruited consecutively from the public lung clinics in Yogyakarta and Dr. Sardjito Hospital, Yogyakarta, Indonesia between October 2013 and December 2015. Healthy controls were recruited from neighboring area of subjects who were diagnosed with PTB. Subjects were aged ≥18 years, agreed to participate in the study, were able to produce sputum (except for healthy controls) and exhaled air samples. Healthy controls should have no sign nor symptoms of TB. Subjects were excluded if they had invalid measurements of breath tests, incomplete CXR data, missing sputum specimens (except for healthy controls), incomplete follow-up, or a previous history of PTB or extra-pulmonary TB. Subjects were further excluded from the analysis if they had cancer, because cancer has been known to interfere with the breath prints [8,9]. All subjects followed the same diagnostic work-up.

The study protocol followed the guidelines of the Helsinki Declaration of 2013, was approved by the institutional review board at the Faculty of Medicine, Universitas Gadjah Mada, Yogyakarta, Indonesia (KE/FK/859/EC), and registered at clinicaltrials.gov (NCT02219945). Written informed consent was obtained from each subject before enrollment in the study.

Test methods

The Aeonose (eNose BV, Zutphen, The Netherlands) is an e-nose device combining 3 different metal-oxide sensors (Applied Sensors Gmbh) and a pre-concentrator (Fig 1). A small pump inside the Aeonose ensures that a constant flow of exhaled air passes the three sensor surfaces and a Tenax tube, which enables detecting low concentrations and high boiling Volatile Organic Compounds (VOCs). A 32-step sinusoidal modulation of the sensor surface with temperature between 260–340°C is used to measure the volatile molecular pattern in exhaled air in terms of sensor’s conductivity values. Study participants breathed normally through the Aeonose via a disposable mouthpiece for 5 min. This mouthpiece contains a High Efficiency Particulate Air-filter protecting the Aeonose from getting contaminated by bacteria and viruses; and a valve and carbon filter that prevents interference by Volatile Organic Compounds (VOCs) in the environment that could distort the measurement. A nose clamp was used to prevent non-filtered air from entering the device and to ensure that the total exhaled volume during tidal breathing passed through the device. After measuring the breath, the sensors are regenerated for 10 minutes. The breath data were downloaded into a laptop, and uploaded onto the website of eNose for analysis.

As part of routine examination, all patients were characterized by clinical symptoms (persistent cough, unintentional ≥5% weight loss, and night sweats), three sputum smear microscopic examinations, and CXR. For research purposes, we added sputum culture, HIV testing, and follow-up for 1.5 years after diagnosis. Patients whose culture results disagreed with the initial clinical diagnosis (i.e. culture was positive for MTB, but the clinical diagnosis was non-PTB, or culture was negative despite a clinical diagnosis of PTB) were followed up for 2.5 years. Results of PTB routine examination were available to those seeing the patients during follow-up, but not to the laboratory personnel who processed the culture.

All these data formed a Composite Reference Standard (CRS) [14,15] that classified participants into four categories: active PTB (subjects who scored PTB by all tests), no PTB or Healthy controls (subjects who scored no-PTB by all tests), and patients whose test results classified in between these two extreme groups (Table 1). Follow-up as a part of a CRS has been used successfully in different settings [1518]. Culture though gold standard for TB but single spot sputum culture is challenging; low quality of sputum samples and laboratory errors may jeopardize both sensitivity and specificity. The CRS that diagnoses TB based on comprehensive results of clinical symptoms, bacteriological examinations, CXR, and follow-up, could address these drawbacks of culture [15,19].

thumbnail
Table 1. Composite reference standard used in the study [1418].

https://doi.org/10.1371/journal.pone.0217963.t001

Demographic data, smoking history, co-morbidities (Type II diabetes mellitus, HIV, COPD, asthma), presence of flu-like illness, presence of psychological stress due to breath test, co-medication including antibiotics, and food and beverage intake ≤8 hours before the test were recorded.

Sample analysis

Sputum Ziehl-Neelsen microscopy and culture on Löwenstein-Jensen media followed WHO guidelines [20], in the TB-Microbiology laboratory, Faculty of Medicine Universitas Gadjah Mada. For research purposes, the CXRs read by the attending physicians were re-read by one independent physician (TSW–a pulmonologist). In case of disagreement, the conclusion from the independent reviewer was followed, and the result of this re-reading was used for the CRS.

The breath data were standardized to facilitate measurements between different Aeonose devices. Temperature control of the sensors was key in order to use multiple metal-oxide sensor eNoses in a single study and later on in validation process; when the sensor temperature was kept within narrow limits, sensors with similar material properties showed similar response to VOC’s. When the sensors age, the signal may decrease due to a reduced number of active sites at the sensor surface. Differences between sensors because of aging were removed in data pre-processing by rescaling the distribution of values (subtracting the mean value or centering the data) so that the mean of observed values is 0 and the standard deviation is 1 [21].

The data were compressed with a TUCKER3-solution, and analyzed using an artificial neural network, thus VOC-samples from individuals could be classified as ‘sick’ or ‘healthy’. Results were obtained for different scaling preprocessing methods, seven sensor combinations and several artificial neural network-topologies resulting in multiple models representing the measurement data. The models were presented in Receiver Operating Characteristic (ROC)-curves indicating trade-offs for sensitivity and specificity of breath test in diagnosing PTB, and the best Area Under the Curve (AUC) was selected. Leave-10%-Out cross validation was applied.

We started with a calibration phase to build a breath model, involving participants in “Active PTB”, “no PTB”, and “Healthy control” groups. The e-nose can only classify unknown patients correctly if the patient characteristics (indication, social status, geographical area) are similar to the ones in the calibration set to have fair classification. Therefore, when collecting the breath samples, we kept participants from the “Probably active PTB” and “Probably no PTB” groups blinded for validation purposes. In this validation phase, the blinded breath samples were classified based on the model generated in the calibration phase [22].

We calculated the sensitivity, specificity, and positive and negative predictive values (PPV and NPV) of the breath test using the CRS as the reference standard. To examine the influence of age, participants were divided into 2 groups, based on the median age. In each variable, one stratum’s Receiver Operating Characteristic (ROC)-curve indicating sensitivity and specificity of breath test was compared with another stratum’s ROC-curve. A significant difference of an AUC between strata (p<0.05) indicated an association between the variable and sensitivity—specificity of the breath test. Statistical analysis was performed using STATA/SE 15 (License: University of Groningen).

To detect a difference of 15% between the CRS and the breath test with a desired sensitivity of 90%, and assuming a prevalence of TB of 36% among the study subjects based on previous data in the lung clinics (unpublished data), with an α error of 0.05 and a power of 90%, the number of patients with suspected PTB needed for the study was 300 [23]. We followed the STARD guidelines for reporting as appropriate.

Results

We included 360 consecutive patients with suspected PTB and 40 healthy controls; 73 study participants were excluded for various reasons, resulting in a total of 327 study participants (Fig 2). Table 2 shows that median age of study participants in calibration and validation phase was 40 (range: 18–85) and 46 (range: 18–85) years old, respectively. Diagnoses for patients who turned out to have no PTB included asthma, pneumonia, bronchiectasis, chronic bronchitis, COPD, Obstructive Syndrome Post TB, lung fibrosis, lung abscess, empyema, and polycystic lung disease.

thumbnail
Table 2. Characteristics of study participants in each category.

https://doi.org/10.1371/journal.pone.0217963.t002

Table 3 shows that in the calibration phase, the number of breath test results with false prediction of the presence of PTB was 57, while number of true breath test results was 125. Fig 3 shows the ROC curve of best model in sensitivity and specificity of breath test in the calibration phase; sensitivity was 85% (95%CI = 75–92) and specificity was 55% (95%CI = 44–65) (Table 4). ROC curves from each strata in various variables are shown in Fig 4, while Table 5 shows that the test was significantly more sensitive and specific for women than for men. Fig 5 shows the ROC curve of best model in sensitivity and specificity of breath test in the validation phase; sensitivity was 78% (95%CI = 70–85%), specificity was 42% (95%CI = 34–50%), PPV was 52% (95%CI = 48–56%), and NPV was 71% (95%CI = 62–78%) (Table 6).

thumbnail
Fig 3. ROC curve of best model in diagnostic sensitivity and specificity of breath test, calibration phase.

ROC = Receiver Operating Characteristic.

https://doi.org/10.1371/journal.pone.0217963.g003

thumbnail
Fig 4. ROC curve of best model in diagnostic sensitivity and specificity of breath test, validation phase.

ROC = Receiver Operating Characteristic.

https://doi.org/10.1371/journal.pone.0217963.g004

thumbnail
Fig 5. ROC curves of sensitivity and specificity of breath test in calibration phase, stratified by variables.

ROC = Receiver Operating Characteristic, AUC = Area Under the Curve. ROC curves of best model in diagnostic sensitivity and specificity of breath test stratified by presence of HIV infection, COPD, asthma, or physiological stress could not be generated due to missing value of sensitivity or specificity in one strata.

https://doi.org/10.1371/journal.pone.0217963.g005

thumbnail
Table 3. Examination results of study participants in each category.

https://doi.org/10.1371/journal.pone.0217963.t003

thumbnail
Table 4. Performance of breath test results in the calibration phase.

https://doi.org/10.1371/journal.pone.0217963.t004

thumbnail
Table 5. Performance of breath test results in the calibration phase, stratified by various variables.

https://doi.org/10.1371/journal.pone.0217963.t005

thumbnail
Table 6. Performance of breath test results in the validation phase.

https://doi.org/10.1371/journal.pone.0217963.t006

There were no adverse events (e.g., breathless, infection, or bleeding) associated with the study intervention.

Discussion

This is the first study testing the e-nose (Aeonose) to diagnose PTB among patients with suspected PTB. The study in Bangladesh used a prototype of the e-nose (participants exhaled into a bag, then the bag content was examined using a laboratory version of the e-nose), and with smaller sample size [11]. Other studies with e-nose devices did not diagnose PTB among patients with suspected PTB [12,24,25]. The sensitivity in our study was modest, while specificity was low.

We evaluated several factors that may associate with the breath prints, i.e. physiological factors (age, sex, food, beverages), pathological and disease-related conditions (smoking, comorbidities, medication), and sampling-related issues (bias with VOCs in the environment) [26]. A previous study revealed that older age altered breath prints in patients with lung cancer [27]. Patients with high body mass index (BMI) had more false-positive test results compared to patients with normal or low BMI [12], males had higher level of isoprene compared to females [28], consuming poultry meat, plant oil, and some beverages could be differentiated by an e-nose, and smoking increased the levels of benzene and pentane [2934]. In our study, we found that the sensitivity and specificity of the breath test were lower in men compared to women. The cause was not entirely clear; higher level of isoprene in men might reflect oxidative stress that can influence the progression of disease [35]. It could be also that a difference in smoking, eating, or other habits influences this difference. To prevent interference by VOCs in the environment such as ethanol and isopropanol [36], the Aeonose was equipped with a valve and carbon filter, thus the breath prints were not biased by the room air.

The Aeonose was developed by using arrays based on less (or non-) specific sensors combined with smart data compression and pattern recognition, namely metal-oxide sensors. This pattern recognition technique matches measured ‘patterns’ to previously ‘seen’ patterns. Therefore, a substance, or mixtures of substances, can only be recognized after a calibration phase: in order to match a pattern, it must be known beforehand (i.e., ‘seen’ before). In exhaled breath, several thousands of VOCs can be recognized. When comparing breath patterns between people suffering from a certain disease and controls, the Aeonose can be taught to differentiate and identify the diseased population. This technique provides less detailed information compared to chemical-analytic methods or spectroscopic techniques that work by detecting VOC markers, although classification of the results remains possible. Philips et al. found that naphthalene, 1-methyl- and cyclohexane, 1,4-dimethyl- were breath VOC markers that are sensitive and specific for pulmonary TB [37]. Detecting these markers might lead to better sensitivity and specificity. However, the insights of what VOC-markers should be picked are changing over time, resulting in other combinations of VOC-markers. The chemical-analytic methods or spectroscopic techniques also have several drawbacks: they need well-conditioned environment, especially when concentration differences of biomarkers are to be recorded; they cannot be used as a point-of-care diagnostic test due to their large size; and well-trained staff are needed to operate the devices.

The Aeonose provides non-invasive diagnosis support in minutes, is easy-to-use, without the need for robust training. In a new release of the Aeonose, an iPad is used, and the test result is provided within seconds. Charging of the device only needs a low electricity usage, as with charging of mobile phones. It is portable, thus suitable as a screening tool. Therefore, it might help to prevent TB transmission, also serve well in health care settings, with further advanced and more expensive testing for individuals picked up by the breath test.

We excluded non-TB patients with a previous history of pulmonary and extra pulmonary TB because several breath profiles of non-TB patients with a previous history of TB showed similar breath profiles with TB. Scares and persistent or dead MTB in the lung could be mimicries of TB [38]. We also excluded patients with cancer because cancer interferes with the breath test [8,9]. We were aware of the fact that in daily practices it is difficult to separate patients with lung cancer from patients with TB as patients with lung cancer are likely to have a clinical presentation that mimics TB, however, the number of patients with cancer was also too low (5 patients) precluding a separate group data analysis. The diagnostic potential if any of the Aeonose for these patients was not addressed in this study.

This study revealed lower sensitivity and specificity in comparison to the study from Bangladesh [11] and Paraguay [12], which is likely caused by the difference in the study populations. In our study, the non-PTB patients were patients with suspected PTB, thus it captured the infectious or non-infectious lung diseases, and acute or chronic lung diseases. In the study from Paraguay, non-TB subjects comprised asthma and COPD patients (patients with stable chronic lung disease), who usually have quite distinct clinical presentations than TB patients. The diversity of participants in our study is larger than in the Bangladesh and Paraguay studies, thus probably more participants are needed in the calibration phase to get comparable performance between calibration and validation phase. When an artificial neural network should predict a breath profile it hasn’t ‘seen’ during the calibration phase, a false prediction is more likely. A larger calibration group would improve the blind predictions.

Using the current sensitivity, 22% of patients would be missed, which is higher than screening by CXR which has 87% sensitivity [39]. Nevertheless, the breath test has advantages of being portable, easy-to-use, and without radiation exposure making it suitable as a repeatable screening test. Notably, approximately 30% of active tuberculosis cases are currently not detected by the national health care system [40]; as calculated within the last TB incidence [1], this test will improve case finding by as many as 67,360 cases. Furthermore, this test has higher sensitivity than symptoms screening, that only had 63% sensitivity from our data, or 70% sensitivity from a previous systematic review [39].

The strength of this study is that cohorts of patients and controls were recruited as a calibration and validation group, with the potential to confirm the correct classification. This study also has some limitations. It was performed in Yogyakarta province alone, however the organization of lung clinics in Yogyakarta is typical and representative for Indonesia. We used Löwenstein-Jensen culture, which has lower sensitivity compared to liquid culture, and we used mostly only one specimen for culture. Nevertheless, Löwenstein-Jensen culture may have higher specificity due to lower contamination rates [4143]. As mentioned above, the e-nose provides less detailed information compared to chemical-analytic methods or spectroscopic techniques. To improve the sensitivity and specificity of the device, a larger calibration group needs to be involved. Once the VOC-markers for TB are adequately determined, the use of highly selective sensors that target these VOC-markers may also add the sensitivity and specificity.

In conclusion, the Aeonose had modest sensitivity and low specificity to diagnose TB among patients with suspected TB in Indonesia. With its portable form, it could be used for TB screening in remote rural areas with difficult access to health care facilities, as well as a screening tool in health care settings to reduce the risk of nosocomial TB transmission.

Supporting information

Acknowledgments

Our high appreciation is addressed to the patients and healthy volunteers for their participation in this study, and to the members of staffs at the public lung clinics and Dr. Sardjito Hospital, Yogyakarta, Indonesia for their cooperation. We thank Althaf Setyawan for his help in the statistical analysis.

References

  1. 1. World Health Organization. Global Tuberculosis Report 2018 [Internet]. Geneva; [cited 2018 Sep 27]. Available from: http://apps.who.int/iris/bitstream/handle/10665/274453/9789241565646-eng.pdf?ua=1
  2. 2. Griffith DE, Brown-Elliott BA, Langsjoen B, Zhang Y, Pan X, Girard W, et al. Clinical and molecular analysis of macrolide resistance in Mycobacterium avium complex lung disease. Am J Respir Crit Care Med. 2006 Oct;174(8):928–34. pmid:16858014
  3. 3. Davies PD, Pai M. The diagnosis and misdiagnosis of tuberculosis. Int J Tuberc Lung Dis. 2008 Nov;12(11):1226–34. pmid:18926032
  4. 4. Albert H, Nathavitharana RR, Isaacs C, Pai M, Denkinger CM, Boehme CC. Development, roll-out and impact of Xpert MTB/RIF for tuberculosis: What lessons have we learnt and how can we do better? Eur Respir J. 2016;48(2):516–25. pmid:27418550
  5. 5. Fens N, Zwinderman AH, van der Schee MP, de Nijs SB, Dijkers E, Roldaan AC, et al. Exhaled breath profiling enables discrimination of chronic obstructive pulmonary disease and asthma. Am J Respir Crit Care Med. 2009 Dec;180(11):1076–82. pmid:19713445
  6. 6. Hattesohl AD, Jorres RA, Dressel H, Schmid S, Vogelmeier C, Greulich T, et al. Discrimination between COPD patients with and without alpha 1-antitrypsin deficiency using an electronic nose. Respirology. 2011 Nov;16(8):1258–64. pmid:21883674
  7. 7. Pavlou AK, Magan N, McNulty C, Jones J, Sharp D, Brown J, et al. Use of an electronic nose system for diagnoses of urinary tract infections. Biosens Bioelectron. 2002 Oct;17(10):893–9. pmid:12243908
  8. 8. Dragonieri S, Annema JT, Schot R, van der Schee MP, Spanevello A, Carratu P, et al. An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD. Lung Cancer. 2009 May;64(2):166–70. pmid:18834643
  9. 9. Kateb B, Ryan MA, Homer ML, Lara LM, Yin Y, Higa K, et al. Sniffing out cancer using the JPL electronic nose: a pilot study of a novel approach to detection and differentiation of brain cancer. Neuroimage. 2009 Aug;47 Suppl 2:T5–9.
  10. 10. Pearce TC, Schiffman SS, Nagle HT, Gardner JW. Handbook of Machine Olfaction. WIley-VCH Verlag GmbH&Co. KGaA; 2003.
  11. 11. Bruins M, Rahim Z, Bos A, van de Sande WW, Endtz HP, van Belkum A. Diagnosis of active tuberculosis by e-nose analysis of exhaled air. Tuberculosis. 2013 Mar;93(2):232–8. pmid:23127779
  12. 12. Coronel Teixeira R, Rodríguez M, Jiménez de Romero N, Bruins M, Gómez R, Yntema JB, et al. The potential of a portable, point-of-care electronic nose to diagnose tuberculosis. J Infect. 2017;75(5):441–7. pmid:28804027
  13. 13. World Health Organization. Health System Profile of Indonesia [Internet]. 2013 [cited 2016 Mar 20]. Available from: http://www.ino.searo.who.int/en/Section3_24.htm
  14. 14. Alonzo TA, Pepe MS. Using a combination of reference tests to assess the accuracy of a new diagnostic test. Stat Med. 1999 Nov;18(22):2987–3003. pmid:10544302
  15. 15. Li S, Liu B, Peng M, Chen M, Yin W, Tang H, et al. Diagnostic accuracy of Xpert MTB/RIF for tuberculosis detection in different regions with different endemic burden: A systematic review and meta-analysis. PLoS One. 2017;12(7):1–13.
  16. 16. Corbett EL, Zezai A, Cheung YB, Bandason T, Dauya E, Munyati SS, et al. Provider-initiated symptom screening for tuberculosis in Zimbabwe: Diagnostic value and the effect of HIV status. Bull World Health Organ. 2010;88(1):13–21. pmid:20428349
  17. 17. Somi GR, O’Brien RJ, Mfinanga GS, Ipuge YA. Evaluation of the MycoDot(TM) test in patients with suspected tuberculosis in a field setting in Tanzania. Int J Tuberc Lung Dis. 1999;3(3):231–8. pmid:10094325
  18. 18. Bah B, Massari V, Sow O, Siriwardana M, Camara LM, Larouzé B, et al. Useful clues to the presence of smear-negative pulmonary tuberculosis in a West African city. Int J Tuberc Lung Dis. 2002;6(7):592–8. pmid:12102298
  19. 19. Saktiawati AMI, Subronto YW, Stienstra Y, Sumardi , Supit F, van der Werf TS. Sensitivity and specificity of routine diagnostic work-up for tuberculosis in lung clinics in Yogyakarta, Indonesia: a cohort study. BMC Public Health [Internet]. 2019 Dec 2 [cited 2019 Apr 5];19(1):Forthcoming. Available from: http://www.ncbi.nlm.nih.gov/pubmed/30940123
  20. 20. World Health Organization. Manual of basic techniques for a health laboratory [Internet]. 2nd ed. Geneva: World Health Organization; 2003 [cited 2017 Mar 28]. Available from: https://apps.who.int/iris/bitstream/handle/10665/42295/9241545305.pdf?sequence=1
  21. 21. Bruins M, Gerritsen JW, Van De Sande WWJ, Van Belkum A, Bos A. Enabling a transferable calibration model for metal-oxide type electronic noses. Sensors Actuators, B Chem. 2013;188:1187–95.
  22. 22. Kort S, Brusse-Keizer M, Gerritsen JW, Van Der Palen J. Data analysis of electronic nose technology in lung cancer: Generating prediction models by means of Aethena. J Breath Res. 2017;11(2):026006. pmid:28373602
  23. 23. Arkin CF, Wachtel MS. How many patients are necessary to assess test performance? JAMA. 1990;263(2):275–8. pmid:2403604
  24. 24. Mohamed EI, Mohamed MA, Moustafa MH, Abdel-Mageed SM, Moro AM, Baess AI, et al. Qualitative analysis of biological tuberculosis samples by an electronic nose-based artificial neural network. Int J Tuberc Lung Dis. 2017;21(7):810–7. pmid:28633707
  25. 25. Zetola NM, Modongo C, Matsiri O, Tamuhla T, Mbongwe B, Matlhagela K, et al. Diagnosis of pulmonary tuberculosis and assessment of treatment response through analyses of volatile compound patterns in exhaled breath samples. J Infect. 2017;74(4):367–76. pmid:28017825
  26. 26. Bikov A, Lázár Z, Horvath I. Established methodological issues in electronic nose research: how far are we from using these instruments in clinical settings of breath analysis? J Breath Res. 2015;9(3):034001. pmid:26056127
  27. 27. Bikov A, Hernadi M, Korosi B, Kunos L, Zsamboki G, Sutto Z, et al. Expiratory flow rate, breath hold and anatomic dead space influence electronic nose ability to detect lung cancer. BMC Pulm Med. 2014;14(1):202.
  28. 28. Lechner M, Moser B, Niederseer D, Karlseder A, Holzknecht B, Fuchs M, et al. Gender and age specific differences in exhaled isoprene levels. Respir Physiol Neurobiol. 2006;154(3):478–83. pmid:16510318
  29. 29. Buratti S, Sinelli N, Bertone E, Venturello A, Casiraghi E, Geobaldo F. Discrimination between washed Arabica, natural Arabica and Robusta coffees by using near infrared spectroscopy, electronic nose and electronic tongue analysis. J Sci Food Agric. 2015;95(11):2192–200. pmid:25258213
  30. 30. Chen Q, Liu A, Zhao J, Ouyang Q. Classification of tea category using a portable electronic nose based on an odor imaging sensor array. J Pharm Biomed Anal. 2013;84:77–83. pmid:23810847
  31. 31. Dutta R, Kashwan KR, Bhuyan M, Hines EL, Gardner JW. Electronic nose based tea quality standardization. Neural Networks. 2003;16(5–6):847–53. pmid:12850043
  32. 32. Yang CJ, Ding W, Ma LJ, Jia R. Discrimination and characterization of different intensities of goaty flavor in goat milk by means of an electronic nose. J Dairy Sci. 2015;98(1):55–67. pmid:25465555
  33. 33. Wojnowski W, Majchrzak T, Dymerski T, Gębicki J, Namieśnik J. Portable Electronic Nose Based on Electrochemical Sensors for Food Quality Assessment. Sensors. 2017;17(12):2715.
  34. 34. Kushch I, Schwarz K, Schwentner L, Baumann B, Dzien A, Schmid , et al. Compounds enhanced in a mass spectrometric profile of smokers’ exhaled breath versus non-smokers as determined in a pilot study using PTR-MS. J Breath Res. 2008;2(2):026002. pmid:21383443
  35. 35. Scholpp J, Schubert JK, Miekisch W, Geiger K. Breath markers and soluble lipid peroxidation markers in critically III patients. Clin Chem Lab Med. 2002;40(6):587–94. pmid:12211653
  36. 36. Ligor T, Bajtarevic A, Buszewski B, Schubert J, Ager C, Klieber M, et al. Noninvasive detection of lung cancer by analysis of exhaled breath. BMC Cancer. 2009;9(1):348.
  37. 37. Phillips M, Cataneo RN, Condos R, Erickson GAR, Greenberg J, Bombardi V La, et al. Volatile biomarkers of pulmonary tuberculosis in the breath. Tuberculosis. 2007 Jan;87(1):44–52. pmid:16635588
  38. 38. Schnappinger D, Ehrt S. A broader spectrum of tuberculosis. Nat Med. 2016;22(10):1076–7. pmid:27711059
  39. 39. van’t Hoog AH, Langendam MW, Mitchell E, Cobelens FG, Sinclair D, Leeflang MMG, et al. A systematic review of the sensitivity and specificity of symptom- and chest-radiography screening for active pulmonary tuberculosis in HIV-negative persons and persons with unknown HIV status. In: World Health Organization, editor. WHO/HTM/TB. Geneva: World Health Organization; 2013. p. 44–7. (Systematic screening for active tuberculosis: principles and recommendations).
  40. 40. Riono P. TB Elimination in Indonesia [Internet]. 2018 [cited 2018 Nov 13]. Available from: http://www.depkes.go.id/resources/download/info-terkini/materiprarakerkesnas2018/PakarTBC.pdf
  41. 41. Lu D, Heeren B, Dunne WM. Comparison of the Automated Mycobacteria Growth Indicator Tube System (BACTEC 960/MGIT) with Lowenstein-Jensen medium for recovery of mycobacteria from clinical specimens. Am J Clin Pathol. 2002 Oct;118(4):542–5. pmid:12375641
  42. 42. Chien HP, Yu MC, Wu MH, Lin TP, Luh KT. Comparison of the BACTEC MGIT 960 with Lowenstein-Jensen medium for recovery of mycobacteria from clinical specimens. Int J Tuberc Lung Dis. 2000 Sep;4(9):866–70. pmid:10985656