Accuracy and reliability of focused echocardiography in patients with Chagas disease from endemic areas: SaMi-Trop cohort study

  • Isabella Morais Martins Barros,

    Roles Conceptualization, Formal analysis, Writing – original draft

    Affiliation Postgraduate Course of Infectious Diseases and Tropical Medicine, School of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil

  • Marcio Vinicius L. Barros,

    Roles Conceptualization, Writing – review & editing

    Affiliation Postgraduate Course of Infectious Diseases and Tropical Medicine, School of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil

  • Larissa Natany Almeida Martins,

    Roles Formal analysis

    Affiliation Department of Statistics, Instituto de Ciências Exatas, Universidade Federal de Minas Gerais. Brazil

  • Antonio Luiz P. Ribeiro,

    Roles Methodology, Writing – review & editing

    Affiliations Postgraduate Course of Infectious Diseases and Tropical Medicine, School of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil, Hospital das Clínicas and Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil

  • Raul Silva Simões de Camargo,

    Roles Data curation, Software

    Affiliation Hospital das Clínicas and Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil

  • Claudia Di Lorenzo Oliveira,

    Roles Project administration, Writing – review & editing

    Affiliation Federal University of São João del-Rei, Divinópolis, Brazil

  • Ariela Mota Ferreira,

    Roles Methodology, Supervision

    Affiliation Health Science Program, Universidade Estadual de Montes Claros, Montes Claros, Brazil

  • Lea Campos de Oliveira,

    Roles Methodology, Supervision

    Affiliation Laboratório de Investigação Médica (LIM03), Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil

  • Ana Luiza Bierrenbach,

    Roles Formal analysis, Supervision

    Affiliation Research and Education Institute–Hospital Sírio-Libanês, São Paulo, Brazil

  • Desireé Sant´Ana Haikal,

    Roles Methodology

    Affiliation Health Science Program, Universidade Estadual de Montes Claros, Montes Claros, Brazil

  • Ester Cerdeira Sabino,

    Roles Funding acquisition, Methodology, Project administration, Supervision

    Affiliation Instituto de Medicina Tropical e Departamento de Moléstias Infecciosas e Parasitarias da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil

  • Clareci S. Cardoso,

    Roles Formal analysis, Writing – review & editing

    Affiliation Federal University of São João del-Rei, Divinópolis, Brazil

  • Maria Carmo Pereira Nunes

    Roles Conceptualization, Formal analysis, Methodology, Supervision, Writing – review & editing

    mcarmo@waymail.com.br

    Affiliations Postgraduate Course of Infectious Diseases and Tropical Medicine, School of Medicine, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil, Hospital das Clínicas and Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil

Abstract

Background

Chagas disease remains a major cause of cardiovascular death in endemic areas. Focused echocardiography (FoCUS) is a point-of-care means of assessing cardiac function which can be useful for the diagnosis of cardiac involvement.

Objective

This study aims evaluating the characteristics of validity and reliability of FoCUS applied on Chagas disease patients.

Methods

Patients with Chagas disease coming from an endemic area were selected from a large cohort (SaMi-Trop). A simplified echocardiogram with only three images was extracted from the conventional echocardiogram performed in this cohort. The images were evaluated by an observer who was blinded to the clinical and echocardiographic data, to determine the accuracy and reliability of FoCUS for cardiac assessment. The analysis constituted of 5 prespecified variables, dichotomized in absence or presence: left ventricular (LV) size and systolic function, right ventricular (RV) size and systolic function, and LV aneurysm.

Results

We included 725 patients with a mean age of 63.4 ± 12.3 years, 483 (67%) female. Abnormal electrocardiogram was observed in 81.5% of the patients. Left and right ventricular dysfunctions were found in 103 (14%) and 49 (7%) of the patients, respectively. Sensitivity, specificity, positive predictive value and negative predictive value were 84%, 94%, 70% and 97% for LV enlargement and 81%, 93%, 68% and 97% for LV systolic dysfunction, respectively, and 46%, 99%, 60% and 98% for RV dilatation, and 37%, 100%, 100% and 96% for RV dysfunction, respectively. Inter and intraobserver agreement were 61% and 87% for LV enlargement and 63% and 92% for LV dysfunction, respectively, and 50% and 49% for RV size and 46% and 79% for RV dysfunction, respectively. LV apical aneurysm was found in 45 patients (6.2%) with the lowest sensitivity of FoCUS study (11%; 95% CI 2–28%).

Conclusions

FoCUS showed satisfactory values of validity and reliability for assessment of cardiac chambers in patients with Chagas disease, except for apical aneurysm. This tool can identify heart disease with potential impact on patient management in the limited-resource setting.

Introduction

Chagas disease (ChD) remains a serious public health problem in Latina America, affecting 6 million of people [1, 2]. Chagas cardiomyopathy is the most severe manifestation of ChD, which is characterized by ventricular enlargement with impairment of segmental or global systolic function, generally associated with typical electrocardiographic (ECG) abnormalities [3].

Echocardiography is a well-established method in the evaluation of patients with ChD. The quantification of myocardial involvement is currently one of the main method indications, providing essential data for therapeutic management and prognostic stratification [4]. However, the scarcity of resources and qualified professionals, especially in remote areas, hinders the proper evaluation of these patients. Therefore, strategies need to be developed to make it more practical and accessible, especially in the setting with limited technological resources.

Focused echocardiography (FoCUS) represents a targeted, standardized echocardiographic examination performed by a physician or properly trained practitioner, using ultrasound as a complement to physical examination to recognize certain signs in specific clinical contexts [5, 6]. Several studies have demonstrated the importance of FoCUS in various cardiac pathologies, including left ventricular dilatation and hypertrophy, left ventricular systolic function assessment, left atrial dilatation, right ventricular morphofunctional assessment, and pericardial effusion [710].

While it is widely tested and validated in emergency and intensive care settings, few studies have evaluated the use of this tool in the context of primary health care for screening in endemic diseases in resource-poor areas [11, 12]. So far there are no studies using FoCUS in the setting of ChD, especially in remote areas. Given this context, the aim of this study was to evaluate the potential of a focused echocardiography protocol in patients with ChD living in remote poor areas to identify features related to cardiac involvement.

Methods

Study population

The patients selected in this study come from a large ongoing cohort, resulting from a partnership between researchers from the states of Minas Gerais and São Paulo, through a project called São Paulo—Minas Gerais Tropical Medicine Research Center (SaMi-Trop). This project has the purpose of developing and conducting research projects on neglected diseases in Brazil, focusing mainly on Chagas disease. This cohort, composed of patients with chronic Chagas cardiomyopathy was established using patients under the care of the Telehealth Network of Minas Gerais Network, a programme designed to support for primary care in the state of Minas Gerais, Brazil, based on ECG results from 2011–2012. Using this database, we selected 21 municipalities within a limited region in the northern part of the State of Minas Gerais where the prevalence of patients with Chagas cardiomyopathy was expected to be high. All eligible participants tested for T. cruzi antibodies using Immunofluorescence and Hemoglutination for T. cruzi. The final cohort consists of adults patients confirmed as seropositive [13].

Phase 1 of the cohort occurred between June 2013 and August 2014, with ECG record and blood collection–C-reactive protein (PCR) and N-terminal pro-brain natriuretic peptide (NT-ProBNP) in 2,157 participants. The echocardiogram was performed in phase 2 by a healthcare professional trained for image acquisition and took place between June 2015 and September 2016, totaling 1,713 participants.

Standard transthoracic echocardiography (TTE) were performed at the primary care units of reference for each patient by a healthcare professional, using the Vivid Q GE® portable device with HD image storage and specific software analysis (Echopac; GE Healthcare, Milwaukee, WI). Standardized parasternal long-axis and short-axis views were obtained, as well as apical views in two, three and four chambers. Assessment of cardiac chambers, valves and diastolic function were performed as recommended [14] and included in the cohort database.

Subsequently, the stored images were analyzed in the SaMi-Trop core lab by experienced echocardiographers. For the present study, a subset of patients was randomly selected for assessment of the cardiac chambers using focused echocardiography.

Ethics statement

The study was approved by the Committee for Ethics in Research of the School of Medicine of the University of São Paulo, number 179.685/2012. All participants were adults (> 18 years old) and signed, in writing and in person, the informed consent form to participate in the study.

Sample size calculation

For this study two sample size calculations were performed. The first calculation was obtained to determine the agreement between the focused echocardiogram and full echocardiogram, aiming at an accuracy of 85%. The sample size was estimated in 195 patients. The second sample was calculated to assess inter-observer variability, using the Kappa (K) concordance test, also known as the Kappa coefficient. We set the Kappa coefficient of 0.85, thus the sample size was estimated in 730 patients. For intra-observer variability, 20% of the sample was used.

Only participants from the SaMi-Trop cohort were included in this study and patients with inadequate image quality were excluded (3%).

Focused echocardiography

From the full conventional echocardiographic study, an independent observer selected only three images. The three images were in two-dimensional mode, in parasternal long-axis, and apical two- and four-chambers views (Fig 1). The selected images were stored on a hard disk (external HD) and evaluated through specific software (Echopac; GE Healthcare, Milwaukee, WI) blinded to the patient data and the results of standard echocardiographic study.

thumbnail
Fig 1. Echocardiographic views selected for the focused echocardiogram.

A: Parasternal long-axis view; B: Apical four-chamber view; C: Apical two-chamber view. LA: left atrium; RA: right atrium; LV: left ventricle; RV: right ventricle.

https://doi.org/10.1371/journal.pone.0258767.g001

The exams were analyzed only by eyeball assessment, without any measurements. The analysis constituted in the five prespecified variables (Fig 2): left ventricular size (0 = normal, 1 = dilated), LV systolic function (0 = normal, 1 = reduced), right ventricular size (0 = normal, 1 = dilated); RV systolic function (0 = normal, 1 = reduced), left ventricular aneurysm (0 = absence, 1 = presence).

thumbnail
Fig 2. Echocardiographic studies of Chagas disease patients.

A: akinesia of inferior wall, basal segment; B: akinesia of lateral basal wall, basal segment; C and D: LV apical aneurysm; E: LV apical thrombus; F: right-sided chambers dilation. LA: left atrium; RA: right atrium; LV: left ventricle; RV: right ventricle.

https://doi.org/10.1371/journal.pone.0258767.g002

Statistical analysis

Categorical variables, expressed as numbers and percentages, were compared using chi-squared testing, whereas continuous data, expressed as mean ± SD, were compared using Student’s unpaired or the Mann-Whitney U test, as appropriate. Correlation analysis were assessed by the Pearson’s or Spearman correlation coefficient, as appropriate.

The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence interval (CI) of each of the five echocardiographic variables from the focused echo were calculated, considering the results of SaMi-Trop reading as a reference. An agreement between the imaging techniques was evaluated by the weighted Kappa statistic (VassarStats, &Richard Lowry 1998–2011).

Fleiss free-marginal Kappa was used to determine intra and inter observer agreement of the 2 readers given that reviewers were blinded to clinical data. The following standards for strength of agreement for the kappa coefficient were used: poor (0.01 to 0.20); slight (0.21 to 0.40); fair (0.41 to 0.60); moderate (0.61 to 0.80); and excellent (0.81 to 1.00).

Statistical analysis was performed using the Statistical Package for Social Sciences for Windows, version 22.0 (SPSS Inc., Chicago, Illinois) and R for Statistical Computing version 2.15.1 (R Foundation, Vienna, Austria).

Results

Patient characteristics

The mean age was 63.4 ± 12.3 years, and 483 were women (67%). The majority were in NYHA functional class I and II at the time of recruitment into the study. The baseline characteristics of the overall population are summarized in Table 1. Previous treatment with benznidazole was reported by 174 patients (24%).

thumbnail
Table 1. Characteristics of the study population (n = 725).

https://doi.org/10.1371/journal.pone.0258767.t001

Regarding ECG findings, 134 patients (18.5%) displayed normal ECG. Right bundle-branch block (RBBB) isolated or associated with left anterior fascicular block (LAFB) was the ECG abnormality found in 224 patients (31%), and atrial fibrillation in 32 patients (4.4%) at enrollment (Table 1).

In the overall patient population, 103 patients (14%) presented with LV systolic dysfunction. The echocardiographic parameters are summarized in Table 2. Patients who had normal or minor ECG abnormalities, LV ejection fraction was within the normal limits, whereas those who presented major ECG changes, including frequent ventricular and ectopic beats, atrial fibrillation, and major isolated ST-T abnormalities had more frequent LV systolic function impairment.

thumbnail
Table 2. Echocardiographic parameters of the study population.

https://doi.org/10.1371/journal.pone.0258767.t002

Table 3 shows ECG findings according to the severity of LV systolic dysfunction. Normal ECG was observed in only 4 patients with ejection fraction below 50%, all of them with mild LV dysfunction.

thumbnail
Table 3. Electrocardiographic findings according to the severity of left ventricular systolic dysfunction.

https://doi.org/10.1371/journal.pone.0258767.t003

FoCUS echocardiography accuracy

Table 4 lists the sensitivity, specificity, negative and positive predictive values, and accuracy for the parameters analyzed between FoCUS and standard echocardiography. The study shows excellent accuracy in the evaluation of LV and RV dimension and function using FoCUS, with the highest values obtained from LV study.

thumbnail
Table 4. Accuracy of FoCUS versus Standard Echocardiography in patients with Chagas disease from the Sami-Trop cohort.

https://doi.org/10.1371/journal.pone.0258767.t004

The evaluation of LV dilatation showed the best sensitivity (0.84; 95% CI 0.75–0.90) among the variables studied, with false negative readings ranged from 10 to 25%. LV systolic function assessment demonstrated excellent results (sensitivity = 0.81; 95% CI 0.71–0.88), with false positive readings ranged from 5% to 9% only. The presence of apical aneurysm showed the poorest sensitivity with FoCUS study (0.11; 95% CI 0.02–0.28). RV size and systolic function by FoCUS found poor sensitivity and high specificity comparing to standard echocardiography, with excellent accuracy.

Observer agreement.

Intraobserver agreement was almost perfect in the evaluation of LV size (κ = 0.87; 95% CI 0.77–0.97) and function (κ = 0.92; 95% CI 0.83–0.99), with substantial agreement in the apical aneurysm (κ = 0.66; 95% CI 0.05–1.0) and RV size (κ = 0.79; 95% CI 0.40–1.0) assessment. RV function showed moderate intraobserver agreement (κ = 0.49; 95% CI 0.11–1.0). The evaluation of interobserver agreement (Table 5) showed substantial agreement from LV size (κ = 0.61; 95% CI 0.51–0.74), LV function (κ = 0.63; 95% CI 0.53–0.74) and apical aneurysm (κ = 0.66; 95% CI 0.05–1.0) and moderate agreement from RV size (κ = 0.50; 95% CI 0.31–0.69) and RV function (κ = 0.46; 95% CI 0.26–0.66).

thumbnail
Table 5. Intraobserver agreement of FoCUS in patients with Chagas disease from the Sami-Trop cohort.

https://doi.org/10.1371/journal.pone.0258767.t005

Discussion

Our study evaluated for the first time the role of FoCUS in a large cohort of ChD from remote areas. The main results can be summarized as follows: (i) there was an excellent accuracy in the evaluation of LV and RV dimension and function; (ii) there was a moderate to substantial intra and interobserver agreement in the FoCUS assessment.

Chagas disease is a potentially lethal condition, but its severity varies widely. Chagas cardiomyopathy is the most serious clinical manifestation of the disease, which is defined by the presence of typical ECG abnormalities in the patients who have positive serological testes against Trypanosoma cruzi [3]. Therefore, identification of heart involvement is essential for accurate risk stratification [15]. Several risk scores have been proposed and developed. However, current risk scores rely on the availability of several diagnostic tests, including echocardiographic examination [1517]. These methods are not readily available in the rural endemic areas and a lack of a health service structure, mainly in remote areas, along with the low levels of awareness among healthcare providers, which leads to cases of chronic Chagas cardiomyopathy be under-recognized.

The SaMi-Trop is one of the largest multicentre cohort study of ChD conducted in the world [13]. The large number of patients included in this investigation is outstanding, especially in a rural and dispersed area. Strategies as focused echocardiography performed by non-physicians and using telehealth in reference centers could facilitate access to more accurate diagnosis, enhancing health care quality in under-serviced communities.

The assessment of the LV function plays a fundamental role in the evaluation of diagnosis and prognosis of chronic ChD. Echocardiography is the noninvasive method of choice in clinical practice for the detection of abnormalities in LV size and function [4]. Patients with ChD may present with predominantly hypokinetic, dilated with diminished LV ejection fraction (LVEF), or biventricular dilatation [18]. Some studies have shown the association between LV diameter and prognosis in patients with Chagas cardiomyopathy. Viotti et al. in a cohort of 856 patients with an 8-year follow-up demonstrated that LV end- systolic diameter was an independent predictor of disease progression and cardiovascular mortality [19]. LV end-systolic diameter was also an independent predictor of mortality or heart transplantation in a study with 231 patients and 19-month follow-up [20]. Issa et al. evaluating Chagas disease patients with irreversible chronic heart failure observed that LV end-diastolic diameter was an independent and significant predictor of mortality or heart transplantation [21].

LV global dysfunction, usually expressed by low LVEF, is the most important predictor of death in Chagas disease [15, 22]. Several studies have demonstrated the prognostic value of systolic dysfunction in patients with ChD. In a systematic review, echocardiographic or cineventriculographic evidence of contractility reduction, expressed qualitatively or quantitatively, was strongly associated with an increased risk of mortality in most studies evaluated [23].

Relevance of the echocardiogram in the evaluation of patients with Chagas disease

In overall population with Chagas disease, echocardiographic evaluation should be performed to assess LV function, regardless of ECG findings. Although the lack of ECG abnormalities mostly rules out significant cardiomyopathy, it is reasonable to perform at least a single echocardiogram as a baseline evaluation on every patient with positive serology for Chagas disease [3]. Individuals with normal ECG may display subtle regional wall motion abnormalities or ventricular aneurysm, which may impact on patient management and follow-up frequency [4]. Echocardiogram should be repeated during follow-up if the ECG becomes abnormal to establish disease progression [31]. In rural areas with very limited resources, a focused echocardiogram could be used as a screening in asymptomatic individuals, which may provide incremental information to ECG.

More recent guidelines recommend that it is reasonable to obtain at least one echocardiogram for patients diagnosed with Chagas disease [3, 4, 31]. This study establishes a baseline for later comparison and can detect the small percentage of patients with subclinical abnormalities despite a normal 12-lead ECG. Echocardiogram should be repeated every 3–5 years in the patients with preserved left ventricular ejection fraction and more often in those who have reduced ejection fraction at the diagnosis or when clinical status change with worsening heart failure or embolic events. The recommendations for echocardiogram in patients with Chagas disease according to the current guidelines are shown in Table 6.

thumbnail
Table 6. Recommendations for echocardiogram in Chagas disease.

https://doi.org/10.1371/journal.pone.0258767.t006

Screening for cardiac dysfunction in Chagas disease: role of FoCUS

Several studies have demonstrated the accuracy of FoCUS in the study of LV, with sensitivity and specificity for size determination varying from 73–100% and 64–93%, respectively and with accuracy superior to 90% in the analysis of LV function [2729]. Our study shows an excellent accuracy and observer concordance in the evaluation of LV size and function. These findings show the potential for a widespread use of FoCUS as a pivotal protocol in the evaluation of ChD patients in endemic areas. A proposed approach based on LV systolic function assessed by FoCUS is shown in Fig 3. Patients who presented LV systolic dysfunction should be referred for a comprehensive echocardiographic evaluation, regardless of ECG findings.

thumbnail
Fig 3. Management of patients with Chagas disease based on FoCUS results.

A proposed approach based on left ventricular systolic function assessed by focused echocardiography.

https://doi.org/10.1371/journal.pone.0258767.g003

LV apical aneurysm, a specific and important characteristic in ChD have a prevalence 6.2% in our cohort, slightly lower than previous studies [18, 30]. However, we obtained poor sensitivity for the evaluation of apical aneurysms. These results could be related to the complex characteristic of apical aneurysm in ChD, generally being necessary several maneuvers for the appropriate assessment of apical region during echocardiographic study. Apical aneurysm may be missed if only conventional apical views are acquired. In order to identify aneurysms, a careful examination requires not only standard views but also angulated apical views. Frequently, a modified four- and two-chambers views aiming posteriorly may be necessary to detect apical aneurysms and thrombus [31]. Therefore, the low sensibility to detect aneurysm in FoCUS is expected. For this specific abnormality, a comprehensive echocardiographic examination is warrant to avoid misdiagnosis of both aneurysm and thrombus, which is often associated with aneurysms.

Right ventricular involvement is common in ChD and it is clear that there is a progression of RV dysfunction among patients with the various forms of ChD [32]. Nevertheless, the echocardiographic study of RV is challenging because of the anatomical and functional complexity of this chamber and the visual assessment of RV size and function could be difficult [14]. Previous studies have investigated the reliability of RV function assessment using “eyeballing” alone showing inconsistent results [33, 34]. In a recent study comparing visual detection of reduced RV function using a RV-focused 4-chamber view comparing with cardiac magnetic resonance (derived RV ejection fraction <50%), sensitivity was 97.1%, 96,8%, 96.5%, and 95.8% and specificity was 55.7%, 52.8%, 54.6%, and 42.5% for the expert, advanced, intermediate, and beginner groups, respectively. For determination of the correct degree of RV dysfunction, even experienced examiners assigned a diagnosis that was discordant with CMR in > 40% of cases, suggesting that visual assessment should be combined with measurement of other parameters of RV function [35]. Ling et al in a study comparing RV evaluation by echocardiography and CMR showed that visual estimation of RV size and function was inaccurate and had wide interobserver variability [36]. Our results demonstrated an excellent accuracy for RV size evaluation and a poor sensitivity and excellent specificity for RV function showing the challenging assessment of this chamber by FoCUS, in agreement with previous studies.

Observer agreement showed good results for visual assessment of LV size and function using FoCUS as previously demonstrated by several studies [27, 29]. However, different study designs and population characteristic among the studies limits an appropriated comparison. Interobserver variability for RV assessment showed only moderate agreement in our study reinforcing the challenge for this chamber evaluation by FoCUS using only visual assessment [35, 36].

Study limitations

This study has several limitations. Echocardiographic studies were performed by non-physicians and could affect the final echocardiographic interpretation. Training for these health professionals consisted of practical training supervised by a cardiologist (MN) at the University’s Echocardiography Laboratory (12 weeks). The interpretation of echocardiograms was limited to cardiologists with extensive experience in echocardiography that probably increased reliability and cannot necessarily be reproduced in other settings.

Additionally, the size of the left and right atria were not evaluated, which is important in the diagnosis and management of patients with Chagas cardiomyopathy. Moreover RV focused apical 4-chamber view was not obtained, which would likely improve the sensitivity of both size and systolic RV function by means of eyeball evaluation.

Conclusions

FoCUS presented satisfactory accuracy and agreement in the morphofunctional assessment of cardiac chambers compared to conventional echocardiography in patients with chronic Chagas disease from endemic areas. This tool may be useful for patient management, especially in the limited-resource setting with difficult access of health care.

References

  1. 1. Chagas C. Nouvelle espèce de trypanosomiase humaine. Bulletin de la Société de Pathologie Exotique, Paris, v.2, n.6, p.304-307. 1909b.
  2. 2. Chagas disease in Latin America: an epidemiological update based on 2010 estimates. Wkly Epidemiol Rec. 2015;90:33–43. pmid:25671846
  3. 3. Nunes MCP, Beaton A, Acquatella H, Bern C, Bolger AF, Echeverría LE et al. Chagas Cardiomyopathy: An update of current clinical Knowledge and Management. A Scientific Statement From the American Heart Association. Circulation. 2018; 138:169–209 pmid:30354432
  4. 4. Acquatella H, Asch FM, Barbosa MM, Barros M, Bern C, Cavalcante JL et al. Recommendations for Multimodality Cardiac Imaging in Patients with Chagas Disease: A Report from the American Society of Echocardiography in Collaboration With the InterAmerican Association of Echocardiography (ECOSIAC) and the Cardiovascular Imaging Department of the Brazilian Society of Cardiology (DIC-SBC). J Am Soc Echocardiogr. 2018;31(1):3–25 pmid:29306364
  5. 5. Spencer KT, Kimura BJ, Korcarz CE, Pellikka PA, Rahklo PS, Siegel RJ. Focused Cardiac Ultrasound: Recomendations from the American Society of Echocardiography. J Am Soc Echocardiogr 2013; 26:567–81 pmid:23711341
  6. 6. Neskovic AN, Edvardsen T, Galderisi M, Garbi M, Gullace G, Jurcut R et al. Focus cardiac ultrasound: the European Association of Cardiovascular. Imaging viewpoint European Heart Journal–Cardiovascular Imaging (2014) 15, 956–960. pmid:24866902
  7. 7. Marbach JA, Almufleh A, Di Santo P, Jung R, Simard T, McInnes M, et al. Comparative Accuracy of Focused Cardiac Ultrasonography and Clinical Examination for Left Ventricular Dysfunction and Valvular Heart Disease: A Systematic Review and Meta-analysis. Ann Intern Med. 2019 Aug 6 pmid:31382273
  8. 8. Liebo MJ, Israel RL, Lillie EO, Smith MR, Rubenson DS, Topol EJ. Is pocket mobile echocardiography the next-generation stethoscope? A cross-sectional comparison of rapidly acquired images with standard transthoracic echocardiography. Ann Intern Med 2011;155 (1):33–8 pmid:21727291
  9. 9. Galderisi M, Santoro A, Versiero M, Lomoriello VS, Esposito R, Raia R, et al. Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study. Cardiovasc Ultrasound. 2010 Nov 26;8:51 pmid:21110840
  10. 10. Xie T, Chamoun AJ, McCulloch M, Tsiouris N, Birnbaum Y, Ahmad M. Rapid screening of cardiac patients with a miniaturized hand-held ultrasound imager: comparisons with physical examination and conventional two-dimensional echocardiography. Clin Cardiol 2004; 27:241–5. pmid:15119702
  11. 11. dos Santos JPA, do Carmo GAL, Beaton AZ, Lourenço TV, Diamantino AC, Nunes MCP et al. Challenges for the Implementation of the First Large-Scale Rheumatic Heart Disease Screening Program in Brazil: The PROVAR Study Experience. Arq Bras Cardiol. 2017; 108(4):370–374 pmid:28538764
  12. 12. Nascimento BR, Sable C, Nunes MCP, Diamantino AC, Oliveira KKB, Oliveira CM, et al. Comparison Between Different Strategies of Rheumatic Heart Disease Echocardiographic Screening in Brazil: Data From the PROVAR (Rheumatic Valve Disease Screening Program) Study. J Am Heart Assoc. 2018 Feb 14;7 (4). pmid:29444774
  13. 13. Cardoso CS, Sabino EC, Oliveira CD, de Oliveira LC, Ferreira AM, Cunha-Neto E, et al. Longitudinal study of patients with chronic Chagas cardiomyopathy in Brazil (SaMi-Trop project): a cohort profile. BMJ Open. 2016 May 4;6 (5):e011181 pmid:27147390
  14. 14. Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L et al. Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc of Echocardiography 2015; vol 28 (1)
  15. 15. Rassi A Jr, Rassi A, Little WC, et al. Development and validation of a risk score for predicting death in Chagas’ heart disease. N Engl J Med 2006; 355:799–808. pmid:16928995
  16. 16. Ribeiro AL, Cavalvanti PS, Lombardi F, et al. Prognostic value of signal-averaged electrocardiogram in Chagas disease. J Cardiovasc Electrophysiol 2008; 19:502–9. pmid:18266670
  17. 17. Benchimol-Barbosa PR, Tura BR, Barbosa EC, et al. Utility of a novel risk score for prediction of ventricular tachycardia and cardiac death in chronic Chagas disease—the SEARCH-RIO study. Braz J Med Biol Res 2013; 46:974–84. pmid:24270912
  18. 18. Acquatella H. Echocardiography in Chagas heart disease. Circulation 2007; 115:1124–31. pmid:17339570
  19. 19. Viotti RJ, Vigliano C, Laucella S, Lococo B, Petti M, Bertocchi G et al. Value of echocardiography for diagnosis and prognosis of chronic Chagas disease cardiomyopathy without heart failure. Heart. 2004;90:655–660 pmid:15145872
  20. 20. Bestetti RB, Otaviano AP, Cardinalli-Neto A, da Rocha BF, Theodoropoulos TA, Cordeiro JA. Effects of B-Blockers on outcome of patients with Chagas’ cardiomyopathy with chronic heart failure. Int J Cardiol. 2011; 151:205–208. pmid:20591516
  21. 21. Issa VS, Amaral AF, Cruz FD, Ferreira SM, Guimarães GV, Chizzola PR et al. Beta-blocker therapy and mortality of patients with Chagas cardiomyopathy: a subanalysis of the REMADHE prospective trial. Circ Heart Fail. 2010; 3:82–88. pmid:19933408
  22. 22. Nunes MC, Dones W, Morillo CA, Encina J, Ribeiro ALP, and Council on Chagas Disease of the Interamerican Society of Cardiology. Chagas disease: an overview of clinical and epidemiological aspects. J Am Coll Cardiol 2013; 62:767–76. pmid:23770163
  23. 23. Rassi A, Rassi SG. Predictors of mortality in chronic Chagas disease: a systematic review of observational studies. Circulation 2007; 115:1101–8. pmid:17339568
  24. 24. Andrade JP, Marin Neto JA, Paola AA, Vilas-Boas F, Oliveira GM, Bacal F et al. I Latin American Guidelines for the diagnosis and treatment of Chagas’ heart disease: executive summary. Arq Bras Cardiol. 2011; 96:434–42. pmid:21789345
  25. 25. Dias JCP, Ramos AN, Gontijo ED, Luquetti A, Shikanai-Yasuda MA, Coura JR et al. II Consenso Brasileiro em Doença de Chagas, 2015. Epidemiol. Serv. Saúde 2016; 25: 7–86.
  26. 26. Benassi MD, Avayú DH, Tomasella MP, Valera ED, Pesce R, Lynch S et al. Consenso Enfermedad de Chagas 2019. Rev Argent Cardiol 2020; 88:1–74.
  27. 27. Chamsi-Pasha MA, Sengupta PP, Zoghbi WA. Handheld Echocardiography Current State and Future Perspectives. Circulation. 2017; 136:2178–2188. pmid:29180495
  28. 28. Razi R, Estrada JR, Doll J, Spencer KT. Bedside Hand-Carried Ultrasound by Internal Medicine Residents Versus Traditional Clinical Assessment for the Identification of Systolic Dysfunction in Patients Admitted with Decompensated Heart Failure. J Am Soc Echocardiogr. 2011 Dec; 24 (12):1319–24. pmid:21885245
  29. 29. Melamed R, Sprenkle MD, Ulstad VK, Herzog CA, Leatherman JW. Assessment of Left Ventricular Function by Intensivists Using Hand-Held Echocardiography. Chest. 2009 Jun; 135(6):1416–1420.
  30. 30. Xavier SS, de Sousa AS, do Brasil PEAA, Gabriel FG, de Holanda MT, Hasslocher-Moreno A. Apical aneurysm in the chronic phase of Chagas disease: prevalence and prognostic value in an urban cohort of 1053 patients. SOCERJ. 2005; 18:351–356.
  31. 31. Nunes MCP, Badano LP, Marin-Neto JA, Edvardsen T, Fernandez-Golf C, Bucciarelli-Ducci C et al. Multimodality imaging evaluation of Chagas disease: an expert consensus of Brazilian Cardiovascular Imaging Department (DIC) and the European Association of Cardiovascular Imaging (EACVI). European Heart Journal—Cardiovascular Imaging (2018) 19, 459–460 pmid:29029074
  32. 32. Romano MMD, Moreira HT, Schmidt A, Maciel BC, Marin-Neto JA. Imaging Diagnosis of Right Ventricle Involvement in Chagas Cardiomyopathy. Biomed Res Int. 2017; 2017:3820191. pmid:28929112
  33. 33. Bellsham-Revell HR, Simpson JM, Miller OI, Bell AJ. Subjective evaluation of right ventricular systolic function in hypoplastic left heart syndrome: how accurate is it? J Am Soc Echocardiogr. 2013;26(1):52–56. pmid:23098782
  34. 34. Magunia H, Schmid E, Hilberath JN, Häberle L, Grasshoff C, Schlensak C, et al. 2D Echocardiographic evaluation of right ventricular function correlates with 3D volumetric models in cardiac surgery patients. J Cardiothorac Vasc Anesth. 2017;31(2):595–601. pmid:28129939
  35. 35. Schneider M., Ran H., Aschauer S., Binder C., Mascherbauer J., Lang I et al. Visual assessment of right ventricular function by echocardiography: how good are we? Int J Cardiovasc Imaging.2019;35: 2001–2008. pmid:31236759
  36. 36. Ling LF, Obuchowski NA, Rodriguez L, Popovic Z, Kwon D, Marwick TH. Accuracy and interobserver concordance of echocardiographic assessment of right ventricular size and systolic function: a quality control exercise. J Am Soc Echocardiogr. 2012;25(7):709–713. pmid:22542275